1.
Validation of the doubly labeled water method using off-axis integrated cavity output spectroscopy and isotope ratio mass spectrometry.
Melanson, EL, Swibas, T, Kohrt, WM, Catenacci, VA, Creasy, SA, Plasqui, G, Wouters, L, Speakman, JR, Berman, ESF
American journal of physiology. Endocrinology and metabolism. 2018;(2):E124-E130
Abstract
When the doubly labeled water (DLW) method is used to measure total daily energy expenditure (TDEE), isotope measurements are typically performed using isotope ratio mass spectrometry (IRMS). New technologies, such as off-axis integrated cavity output spectroscopy (OA-ICOS) provide comparable isotopic measurements of standard waters and human urine samples, but the accuracy of carbon dioxide production (V̇co2) determined with OA-ICOS has not been demonstrated. We compared simultaneous measurement V̇co2 obtained using whole-room indirect calorimetry (IC) with DLW-based measurements from IRMS and OA-ICOS. Seventeen subjects (10 female; 22 to 63 yr) were studied for 7 consecutive days in the IC. Subjects consumed a dose of 0.25 g H218O (98% APE) and 0.14 g 2H2O (99.8% APE) per kilogram of total body water, and urine samples were obtained on days 1 and 8 to measure average daily V̇co2 using OA-ICOS and IRMS. V̇co2 was calculated using both the plateau and intercept methods. There were no differences in V̇co2 measured by OA-ICOS or IRMS compared with IC when the plateau method was used. When the intercept method was used, V̇co2 using OA-ICOS did not differ from IC, but V̇co2 measured using IRMS was significantly lower than IC. Accuracy (~1-5%), precision (~8%), intraclass correlation coefficients ( R = 0.87-90), and root mean squared error (30-40 liters/day) of V̇co2 measured by OA-ICOS and IRMS were similar. Both OA-ICOS and IRMS produced measurements of V̇co2 with comparable accuracy and precision compared with IC.
-
2.
Rapid discrimination of human oesophageal squamous cell carcinoma by mass spectrometry based on differences in amino acid metabolism.
Jianyong, Z, Jianjun, X, Yongzhong, O, Junwen, L, Haiyan, L, Dongliang, Y, Jinhua, P, Junwen, X, Huanwen, C, Yiping, W
Scientific reports. 2017;(1):3738
Abstract
Oesophageal cancer (OC) is associated with high morbidity and mortality, and surgery is the most effective approach to treat it. In order to reduce surgical risks and duration of surgery, we explored a new strategy to determine tumour margins in surgery. In this study, we included 128 cancerous and 128 noncancerous database entries obtained from 32 human patients. Using internal extractive electrospray ionization-MS, in positive ion detection mode, the relative abundances of m/z 104.13, m/z 116.10, m/z 132.13, and m/z 175.13 were higher in cancer tissue while the relative abundances of m/z 82.99, m/z 133.11, m/z 147.08, m/z 154.06, and m/z 188.05 were higher in normal tissue. Using partial least squares analysis, the mass spectra of cancer samples was discriminated from those of normal tissues, and the discriminatory ions were obtained from loading plots. Dimethylglycine(m/z 104), proline(m/z 116), isoleucine(m/z 132), asparagine(m/z 133), glutamine(m/z 147), and arginine(m/z 175) were identified by collision-induced dissociation experiments. Using the ROC curve analysis, we verified the validity of six amino acids for the identification of tumour tissue. Further investigations of tissue amino acids may allow us to better understand the underlying mechanisms involved in OC and develop novel means to identify tumour tissue during operation.
-
3.
Comparison of Two ELISA Methods and Mass Spectrometry for Measurement of Vitamin D-Binding Protein: Implications for the Assessment of Bioavailable Vitamin D Concentrations Across Genotypes.
Denburg, MR, Hoofnagle, AN, Sayed, S, Gupta, J, de Boer, IH, Appel, LJ, Durazo-Arvizu, R, Whitehead, K, Feldman, HI, Leonard, MB, et al
Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research. 2016;(6):1128-36
-
-
Free full text
-
Abstract
Studies using vitamin D-binding protein (DBP) concentrations to estimate free and bioavailable vitamin D have increased dramatically in recent years. Combinations of two single-nucleotide polymorphisms (SNPs) produce three major DBP isoforms (Gc1f, Gc1s, and Gc2). A recent study showed that DBP concentrations quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) did not differ by race, whereas a widely used monoclonal enzyme-linked immunosorbent assay (ELISA) quantified DBP differentially by isoform, yielding significantly lower DBP concentrations in black versus white individuals. We compared measurements of serum DBP using a monoclonal ELISA, a polyclonal ELISA, and LC-MS/MS in 125 participants in the Chronic Renal Insufficiency Cohort (CRIC). Serum free and bioavailable 25OHD were calculated based on DBP concentrations from these three assays in homozygous participants, and race differences were compared. We confirmed that the monoclonal ELISA quantifies DBP differentially by isoform and showed that the polyclonal ELISA is not subject to this bias. Whereas ≤9% of the variability in DBP concentrations quantified using either LC-MS/MS or the polyclonal ELISA was explained by genotype, 85% of the variability in the monoclonal ELISA-based measures was explained by genotype. DBP concentrations measured by the monoclonal ELISA were disproportionately lower than LC-MS/MS-based results for Gc1f homozygotes (median difference -67%; interquartile range [IQR] -71%, -64%), 95% of whom were black. In contrast, the polyclonal ELISA yielded consistently and similarly higher measurements of DBP than LC-MS/MS, irrespective of genotype, with a median percent difference of +50% (IQR +33%, +65%). Contrary to findings using the monoclonal ELISA, DBP concentrations did not differ by race, and free and bioavailable 25OHD were significantly lower in black versus white participants based on both the polyclonal ELISA and LC-MS/MS, consistent with their lower total 25OHD. Future studies of DBP and free or bioavailable vitamin D metabolites should employ DBP assays that are not biased by DBP genotype. © 2016 American Society for Bone and Mineral Research.
-
4.
Mass spectrometry evaluation of the hepcidin-25 assay in the differential diagnosis of iron deficiency anaemia with concurrent inflammation and anaemia of inflammation in elderly patients.
Karlsson, T
European journal of haematology. 2015;(5):467-71
Abstract
In this study, mass spectrometry was used to evaluate the hepcidin-25 assay in the differential diagnosis of iron deficiency anaemia with concurrent inflammation and anaemia of inflammation in elderly patients using the absence of stainable bone marrow iron as the gold standard criterion for iron deficiency (ID). In addition, correlation coefficients for hepcidin-25 vs. haematimetric and biochemical iron parameters, and C-reactive protein (CRP) were determined. The optimal cut-off for hepcidin-25 was 31.5 ng/mL corresponding to a sensitivity and specificity of 82% and 95%, respectively, for ID. For ferritin, a sensitivity and specificity of 70% and 100%, respectively, correspond to an optimal cut-off of 41.5 μg/L. Receiver operating characteristics curve analysis revealed that mass spectrometry analysis of hepcidin-25 does not appear to be superior to ferritin in the diagnosis of ID in elderly anaemic patients with concurrent inflammation. Hepcidin-25 shows a strong positive correlation with ferritin, and also correlates positively with CRP, in this patient population.
-
5.
The use of a portable breath analysis device in monitoring type 1 diabetes patients in a hypoglycaemic clamp: validation with SIFT-MS data.
Walton, C, Patel, M, Pitts, D, Knight, P, Hoashi, S, Evans, M, Turner, C
Journal of breath research. 2014;(3):037108
Abstract
Monitoring blood glucose concentrations is a necessary but tedious task for people suffering from diabetes. It has been noted that breath in people suffering with diabetes has a different odour and thus it may be possible to use breath analysis to monitor the blood glucose concentration. Here, we evaluate the analysis of breath using a portable device containing a single mixed metal oxide sensor during hypoglycaemic glucose clamps and compare that with the use of SIFT-MS described in previously published work on the same set of patients. Outputs from both devices have been correlated with the concentration of blood glucose in eight volunteers suffering from type 1 diabetes mellitus. The results demonstrate that acetone as measured by SIFT-MS and the sensor output from the breath sensing device both correlate linearly with blood glucose; however, the sensor response and acetone concentrations differ greatly between patients with the same blood glucose. It is therefore unlikely that breath analysis can entirely replace blood glucose testing.
-
6.
Development, validation and application of a stable isotope dilution liquid chromatography electrospray ionization/selected reaction monitoring/mass spectrometry (SID-LC/ESI/SRM/MS) method for quantification of keto-androgens in human serum.
Tamae, D, Byrns, M, Marck, B, Mostaghel, EA, Nelson, PS, Lange, P, Lin, D, Taplin, ME, Balk, S, Ellis, W, et al
The Journal of steroid biochemistry and molecular biology. 2013;:281-9
-
-
Free full text
-
Abstract
Prostate cancer is the most frequently diagnosed form of cancer in males in the United States. The disease is androgen driven and the use of orchiectomy or chemical castration, known as androgen deprivation therapy (ADT) has been employed for the treatment of advanced prostate cancer for over 70 years. Agents such as GnRH agonists and non-steroidal androgen receptor antagonists are routinely used in the clinic, but eventually relapse occurs due to the emergence of castration-resistant prostate cancer. With the appreciation that androgen signaling still persists in these patients and the development of new therapies such as abiraterone and enzalutamide that further suppresses androgen synthesis or signaling, there is a renewed need for sensitive and specific methods to quantify androgen precursor and metabolite levels to assess drug efficacy. We describe the development, validation and application of a stable isotope dilution liquid chromatography electrospray ionization selected reaction monitoring mass spectrometry (SID-LC/ESI/SRM/MS) method for quantification of serum keto-androgens and their sulfate and glucuronide conjugates using Girard-T oxime derivatives. The method is robust down to 0.2-4pg on column, depending on the androgen metabolite quantified, and can also quantify dehydroepiandrosterone sulfate (DHEA-S) in only 1μL of serum. The clinical utility of this method was demonstrated by analyzing serum androgens from patients enrolled in a clinical trial assessing combinations of pharmacological agents to maximally suppress gonadal and adrenal androgens (Targeted Androgen Pathway Suppression, TAPS clinical trial). The method was validated by correlating the results obtained with a hydroxylamine derivatization procedure coupled with tandem mass spectrometry using selected reaction monitoring that was conducted in an independent laboratory.
-
7.
Enantiomeric determination of tramadol and O-desmethyltramadol in human plasma by fast liquid chromatographic technique coupled with mass spectrometric detection.
Chytil, L, Matousková, O, Cerná, O, Pokorná, P, Vobruba, V, Perlík, F, Slanar, O
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2010;(3-4):481-6
Abstract
A rapid and sensitive method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for enantiomeric determination of tramadol and its primary phase metabolite O-desmethyltramadol in human plasma has been developed. Tramadol hydrochloride-(13)C, d(3), was used as an isotopic labeled internal standard for quantification. The method involves a simple solid phase extraction. The analytes and internal standard were separated on Lux Cellulose-2 packed with cellulose tris(3-chloro-4-methylphenylcarbamate) using isocratic elution with hexane/isopropanol/diethylamine (90:10:0.1, v/v/v) at a flow rate of 1.3 mL/min. The APCI positive ionization mass spectrometry was used with multiple reaction monitoring of the transitions at m/z 264.2-->58.2 for tramadol, m/z 250.1-->58.2 for O-desmethyltramadol and m/z 268.2-->58.2 for internal standard. Linearity was achieved between 1-800 ng/mL and 1-400 ng/mL (R(2) > or = 0.999) for each enantiomer of tramadol and O-desmethyltramadol, respectively. Intra-day accuracies ranged among 98.2-102.8%, 97.1-109.1% and 97.4-102.9% at the lower, intermediate, and high concentration for all analytes, respectively. Inter-day accuracies ranged among 95.5-104.1%, 99.2-104.7%, and 94.2-105.6% at the lower, intermediate, and high concentration for all analytes, respectively. This assay was successfully used to determine the concentration of enantiomers of tramadol and O-desmethyltramadol in a pharmacogenetic study.