0
selected
-
1.
Nanocurcumin supplementation ameliorates Behcet's disease by modulating regulatory T cells: A randomized, double-blind, placebo-controlled trial.
Abbasian, S, Soltani-Zangbar, MS, Khabbazi, A, Farzaneh, R, Malek Mahdavi, A, Motavalli, R, Hajialilo, M, Yousefi, M
International immunopharmacology. 2021;(Pt B):108237
Abstract
Current research was designed to assess the effects of nanocurcumin supplementation on regulatory T (Treg) cells frequency and function in Behçet's disease (BD). In this randomized double-masked, placebo-controlled trial, 36 BD subjects were randomly put into two groups to take one 80 mg nanocurcumin capsule or placebo daily for 8 weeks. Before and after trial, disease activity, Treg cells frequency and expression of related immunologic parameters including forkhead box protein P3 (Foxp3) transcription factor messenger RNA (mRNA) and microRNAs (miRNAs) such as miRNA-25 and miRNA-106b as well as cytokines including transforming growth factor (TGF)-β and interleukin (IL)-10 were studied. Thirty-two patients (17 in the nanocurcumin and 15 in the placebo groups) completed the trial. Treg cells frequency increased significantly in the nanocurcumin group compared with baseline (P < 0.001) and placebo group (P < 0.001). Moreover, FoxP3, TGF-β, IL-10, miRNA-25, and miRNA-106b mRNA expression levels increased considerably in the nanocurcumin group compared to baseline (P < 0.001) and placebo group (P < 0.001, P < 0.001, P = 0.025, P = 0.011, and P < 0.001, respectively). Significant increases in serum TGF-β and IL-10 were seen in nanocurcumin group compared with baseline (P < 0.001) and placebo group (P = 0.001 and P < 0.001, respectively). Significant decrease in disease activity was found in nanocurcumin group compared with placebo group (P = 0.044). Our study provided a promising view for desirable effects of nanocurcumin supplementation in improving immunological parameters and disease activity in BD.
-
2.
Safety and effectiveness of maxillary early loaded titanium implants with a novel nanostructured calcium-incorporated surface (Xpeed): 1-year results from a pilot multicenter randomised controlled trial.
Esposito, M, Grusovin, MG, Pellegrino, G, Soardi, E, Felice, P
European journal of oral implantology. 2012;(3):241-9
Abstract
PURPOSE To evaluate clinical safety and effectiveness of a novel calcium-incorporated titanium implant (Xpeed, MegaGen Implant Co. Limited, Gyeongbuk, South Korea). MATERIALS AND METHODS Sixty patients were randomised to receive either 1 to 6 calcium-incorporated or control titanium implants in the maxilla according to a parallel group design at 2 different centres. Implants were submerged and exposed at 3 different endpoints in equal groups of 20 patients each at 12, 10 and 8 weeks, respectively. Within 2 weeks, implants were functionally loaded with provisional or definitive prostheses. Outcome measures were prosthesis failures, implant failures, any complications and peri-implant marginal bone level changes. RESULTS Thirty patients received 45 calcium-incorporated implants and 30 patients received 42 control titanium implants. One year after loading, no drop-outs and no prosthesis or implant failures occurred. There were no statistically significant differences between groups for complications (P = 0.61; difference in proportions = -0.27; 95% CI -0.71 to 0.18) and mean marginal bone level changes (P = 0.64; mean difference -0.04 mm; 95% CI -0.22 to 0.13). CONCLUSIONS Nanostructured calcium-incorporated titanium implants seem to be at least as effective and safe as conventional titanium implants.
-
3.
Remineralization of early caries by a nano-hydroxyapatite dentifrice.
Najibfard, K, Ramalingam, K, Chedjieu, I, Amaechi, BT
The Journal of clinical dentistry. 2011;(5):139-43
Abstract
OBJECTIVE The purpose of this randomized, double-blind, crossover, in situ study was to evaluate the efficacy of nano-hydroxyapatite (nHAP) dentifrices on caries remineralization and demineralization inhibition. METHODS Three demineralized enamel blocks (A,B,C) and one healthy block (D), cut from each of 30 molars, were exposed respectively to dentifrices of A) 5% nHAP, B) 10% nHAP, C) 1100 ppm fluoride, and D) 10% nHAP via an intra-oral appliance worn by 30 adults in this four-phase study lasting 28 days per phase. Baseline and post-test mineral loss (delta Z) and lesion depth (LD) were quantified using microradiography. RESULTS Pair-wise comparison (baseline versus test) demonstrated significant (p < 0.001) reductions in delta Z and LD in A, B, and C. ANOVA showed no significant differences among the three products in percent mineral gain. No demineralization occurred in the sound enamel specimens exposed intra-orally while using 10% nHAP. CONCLUSION nHAP dentifrice caused remineralization comparable to a fluoride dentifrice, and inhibited caries development, thus suggesting that an nHAP dentifrice can be an effective alternative to fluoride toothpaste.
-
4.
Shear bond strength of three different nano-restorative materials to dentin.
Korkmaz, Y, Gurgan, S, Firat, E, Nathanson, D
Operative dentistry. 2010;(1):50-7
Abstract
OBJECTIVES To evaluate the shear bond strength (SBS) of a nano-composite, a flowable nano-composite and a nano glass ionomer to dentin in vitro. MATERIALS AND METHODS Sixty human molars were ground flat, exposing the dentin surfaces, and they were randomly divided into five groups according to the restorative materials and adhesive systems used (n = 12/group). The restoratives were applied to all dentin surfaces according to the manufacturer's instructions, using a special jig (Ultradent) in the following manner: Group 1: a nano-composite (NC) (Filtek Supreme XT-3M ESPE) was applied with a two-step self-etch adhesive (SE) (Adper SE Plus-3M ESPE); Group 2: NC was applied with an etch&rinse adhesive (SB) (Adper Single Bond 2-3M ESPE); Group 3: a flowable nano-composite (FNC, Filtek Supreme XT Flow-3M ESPE) was applied with SE; Group 4: FNC was applied with SB and Group 5: a nanofilled resin-modified glass ionomer (Ketac N100-3M ESPE) was applied with Ketac Nano Primer (3M ESPE). The bonded specimens were stored in distilled water (37 degrees C, 24 hours) and tested for SBS in a universal testing machine (1 mm/minute). Two specimens from each group were subjected to SEM evaluations of the adhesive interfaces. Failure modes were determined using a stereomicroscope. The mean SBS values were calculated and the data were analyzed with the Kruskal Wallis and Mann-Whitney-U tests (p < 0.05). RESULTS Mean SBS values (MPa) for the groups were 13.64; 7.83; 11.20; 4.12 and 0.64 for Groups 1, 2, 3, 4 and 5, respectively. Group 1 exhibited a significantly higher value than all the other groups; whereas, Group 5 had the lowest value (p < 0.05). The SE adhesive yielded higher bond values than the SB adhesive with NC and FNC restorative materials. Failure modes in all the groups were primarily adhesive. CONCLUSION The results demonstrate the capacity of the current two-step self-etch adhesive to outperform the etch&rinse adhesive in conjunction with the two nano-restoratives tested.
-
5.
Assessment of the effectiveness of nontransdermal energy patches on muscle endurance and power.
Jacobson, BH, Smith, DB, Stemm, JD, Warren, AJ, O'Brien, MS, Glass, RG
Journal of strength and conditioning research. 2008;(3):869-73
Abstract
Claims of recently developed energy patches suggest that organic nanoscale biomolecular "antennas" produced by L and D-stereoisomers resonate at frequencies in unison with molecules in the cells inducing electron flow to assists in recruiting calcium ions, allowing greater muscle fiber recruitment during muscle contraction. The purpose of the study was to assess the efficacy of energy patches in the performance of selected muscle power and endurance measures. After a 5-minute warm-up and stretch, 41 college varsity football players (age, 20.37 +/- 1.24 years; height, 169.91 +/- 7.44 cm; weight, 109.45 +/- 19.85 kg) were pre-tested on 102-kg maximal bench press repetitions, standing vertical jump, grip strength, peak torque, torque to body weight, total work, average power, and average torque as measured by 50 repetitions of leg extensions at 180 degrees .s. The following week, the players were randomly assigned the experimental or placebo patches. After placement of the patches, the participants again completed a 5-minute warm-up, followed by the identical pre-test protocol. Repeated-measures ANOVAs were used to compare resultant data. No significant group interaction effects were found between experimental and placebo patches for maximal bench press repetitions (p = 0.48), vertical jump distance (p = 0.39), grip strength (p = 0.29), total work (p = 0.26), torque to body weight (p = 0.05), average peak torque (p = 0.08), and average power (p = 0.05). A significant increase occurred in the experimental group for peak torque (p = 0.04). It was concluded that the energy patches significantly improved performance over placebo patches in one of the eight variables tested and registered near significance in two additional variables. However, inconsistency in overall results demands further studies to determine the reliability in improvement of performance in the presence of energy patches.