1.
Antithrombotic Therapy in Patients With Atrial Fibrillation After Acute Coronary Syndromes or Percutaneous Intervention.
Harskamp, RE, Fanaroff, AC, Lopes, RD, Wojdyla, DM, Goodman, SG, Thomas, LE, Aronson, R, Windecker, S, Mehran, R, Granger, CB, et al
Journal of the American College of Cardiology. 2022;(5):417-427
Abstract
BACKGROUND The use of apixaban instead of vitamin K antagonists (VKA) as well as dropping aspirin results in less bleeding and comparable ischemic events in patients with atrial fibrillation and acute coronary syndrome and/or percutaneous coronary intervention treated with a P2Y12 inhibitor. OBJECTIVES The authors assessed the safety and efficacy of antithrombotic regimens according to HAS-BLED and CHA2DS2-VASc scores in AUGUSTUS (The Open-Label, 2 × 2 Factorial, Randomized, Controlled Clinical Trial to Evaluate the Safety of Apixaban vs. Vitamin K Antagonist and Aspirin vs. Placebo in Patients with Atrial Fibrillation and Acute Coronary Syndrome and/or Percutaneous Coronary Intervention). METHODS In AUGUSTUS, 4,614 patients were randomized in a 2-by-2 factorial design to open-label apixaban or VKA and blinded aspirin or placebo. The primary endpoint was major or clinically relevant nonmajor bleeding over 6 months of follow-up. Cox proportional hazards models were used to assess treatment effects by baseline HAS-BLED (≤2 vs ≥3) and CHA2DS2-VASc (≤2 vs ≥3) scores. RESULTS Of 4,386 (95.1%) patients with calculable scores, 66.8% had HAS-BLED ≥3 and 81.7% had CHA2DS2-VASc ≥3. Bleeding rates were lower with apixaban than VKA irrespective of baseline risk (HR: 0.57; 95% CI: 0.41-0.78 [HAS-BLED ≤2]; HR: 0.72; 95% CI: 0.59-0.88 [HAS-BLED ≥3]; interaction P = 0.23). Aspirin increased bleeding irrespective of baseline risk (HR: 1.86; 95% CI: 1.36-2.56 [HAS-BLED ≤2]; HR: 1.81; 95% CI: 1.47-2.23 [HAS-BLED ≥3]; interaction P = 0.88). Apixaban resulted in a lower risk of death or hospitalization than VKA without a significant interaction with baseline stroke risk (HR: 0.92; 95% CI: 0.67-1.25 [CHA2DS2-VASc ≤2]; HR: 0.82; 95% CI: 0.73-0.94 [CHA2DS2-VASc ≥3]; interaction P = 0.53). CONCLUSIONS Our findings support the use of apixaban and a P2Y12 inhibitor without aspirin for most patients with atrial fibrillation and acute coronary syndrome and/or percutaneous coronary intervention, irrespective of a patient's baseline bleeding and stroke risk (NCT02415400).
-
2.
Trends of Antithrombotic Treatment in Atrial Fibrillation Patients Undergoing Percutaneous Coronary Intervention: Insights from the GReek-AntiPlatElet Atrial Fibrillation (GRAPE-AF) Registry.
Benetou, DR, Varlamos, C, Ktenas, D, Tsiafoutis, I, Koutouzis, M, Bampali, T, Mantis, C, Zarifis, J, Skalidis, E, Aravantinos, D, et al
Cardiovascular drugs and therapy. 2021;(1):11-20
Abstract
PURPOSE Patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) are a high-risk subset of patients, whose optimal antithrombotic treatment strategy, involving a combination of anticoagulant and antiplatelet agents, has not been well defined. Our study aims to investigate contemporary "real-world" trends of antithrombotic treatment strategies in AF patients undergoing PCI, as well as identify factors affecting decision-making at hospital discharge. METHODS "Real-world" data were retrieved from the GReek-AntiPlatElet Atrial Fibrillation (GRAPE-AF) registry, a contemporary, nationwide, multicenter, observational study of AF patients undergoing PCI. Characteristics of patients discharged on triple antithrombotic therapy (TAT) or dual antithrombotic therapy (DAT) were compared in order to identify factors that could influence treatment decisions. RESULTS A total of 654 patients were enrolled (42% with stable coronary artery disease, 58% with acute coronary syndrome). TAT was adopted in 49.9% and DAT in 49.2% of patients at discharge. Regarding anticoagulants, the vast majority of patients (92.9%) received non-vitamin K antagonist oral anticoagulants (NOACs) and only 7.1% received vitamin K antagonists (VKAs). Dyslipidemia, insulin-dependent diabetes mellitus, prior myocardial infarction, acute coronary syndrome at presentation, and regional variations were predictive of TAT adoption, whereas the use of NOACs or ticagrelor was predictive of DAT adoption. CONCLUSION Contemporary "real-world" data concerning antithrombotic treatment in AF patients undergoing PCI indicate a strong shift towards the use of NOACs instead of VKAs, along with a large subset of patients adopting an aspirin-free strategy early after index PCI, with clinical as well as treatment characteristics affecting decision-making. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT03362788 (First Posted: December 5, 2017).
-
3.
Details on the effect of very short dual antiplatelet therapy after drug-eluting stent implantation in patients with high bleeding risk: insight from the STOPDAPT-2 trial.
Watanabe, H, Domei, T, Morimoto, T, Natsuaki, M, Shiomi, H, Toyota, T, Ohya, M, Suwa, S, Takagi, K, Nanasato, M, et al
Cardiovascular intervention and therapeutics. 2021;(1):91-103
-
-
Free full text
-
Abstract
Previously we briefly reported the effect of 1-month dual antiplatelet therapy (DAPT) for patients with high bleeding risk (HBR) receiving percutaneous coronary intervention (PCI) in the STOPDAPT-2 trial, but full analysis data have not been available. We conducted post hoc subgroup analysis regarding the effect of very short DAPT for HBR patients in STOPDAPT-2 trial. The primary endpoint was a 1-year composite of cardiovascular (cardiovascular death, myocardial infarction, definite stent thrombosis, or stroke) and bleeding (TIMI major/minor bleeding) outcomes. Major secondary endpoints were 1-year cardiovascular composite endpoint and bleeding endpoint. HBR was defined by the academic research consortium (ARC) HBR criteria. Among the 3009 study patients, 1054 (35.0%) were classified as HBR and 1955 (65.0%) were as non-HBR. There were no significant interactions between HBR/non-HBR subgroups and the assigned DAPT group on the primary endpoint (HBR; 3.48% vs. 5.98%, HR 0.57, 95% CI 0.32-1.03, and non-HBR; 1.81% vs. 2.36%, HR 0.78, 95% CI 0.42-1.45; P for interaction = 0.48), the major secondary cardiovascular endpoint (HBR; 3.07% vs. 4.03%, HR 0.77, 95% CI 0.40-1.48, and non-HBR; 1.41% vs. 1.61%, HR 0.89, 95% CI 0.43-1.84; P for interaction = 0.77), and the major secondary bleeding endpoint (HBR; 0.41% vs. 2.71%, HR 0.15, 95% CI 0.03-0.65, and non-HBR; 0.40% vs. 0.85%, HR 0.48, 95% CI 0.14-1.58; P for interaction = 0.22). In conclusion, the effects of 1-month DAPT for the primary and major secondary endpoints were consistent in HBR and non-HBR patients without any significant interactions. The benefit of 1-month DAPT in reducing major bleeding was numerically greater in HBR patients.Clinical trial registration Short and optimal duration of dual antiplatelet therapy after everolimus-eluting cobalt-chromium stent-2 [STOPDAPT-2]; NCT02619760.
-
4.
Efficacy of Sodium Tanshinone IIA Sulfonate in Patients with Non-ST Elevation Acute Coronary Syndrome Undergoing Percutaneous Coronary Intervention: Results from a Multicentre, Controlled, Randomized Trial.
Mao, S, Wang, L, Zhao, X, Guo, L, Lin, Q, Wang, X, Dai, X, Shang, H, Zhang, M, Hinek, A
Cardiovascular drugs and therapy. 2021;(2):321-329
Abstract
BACKGROUND Sodium tanshinone IIA sulfonate (STS) has been widely used by Chinese medicine practitioners for chronic cardiovascular diseases. However, its direct clinical efficacy in patients with acute coronary syndrome following percutaneous coronary intervention (PCI) has not been reported yet. The present trial aimed to investigate potential cardioprotection of STS in patients undergoing PCI for non-ST elevation acute coronary syndrome (NSTE-ACS). METHODS In a randomized, double-blind, placebo-controlled trial, 372 patients with NSTE-ACS were randomly assigned to receive STS (n = 192) or saline (n = 180) for 2 days before and 3 days after PCI along with standard therapy. The primary endpoint was the composite incidence of major adverse cardiac events (MACEs), including death, non-fatal myocardial infarction, repeated revascularization of the target vessel, and stent thrombosis, within 30 days after PCI. RESULTS The 30-day MACEs occurred in 18.8% of the patients in the STS group and in 27.2% of the patients in the control group (P = 0.038); this difference was mostly driven by reduction of myocardial infarction incidence (17.2% vs. 26.7%, P = 0.027). Post-procedural elevation of troponin-I was also significantly lower in the STS group (26.56% vs. 47.78%, P < 0.001). Multivariable analysis identified STS as a predictor of decreased risk of MACE occurrence (odds ratio: 0.60, 95% confidence interval: 0.36 to 0.99; P = 0.045). CONCLUSION Addition of STS to the standard treatments recommended by the current practice guidelines in patients with NSTE-ACS undergoing PCI could reduce myocardial injury and the occurrence of short-term cardiovascular events, primarily driven by non-fatal myocardial infarction. TRIAL REGISTRATION ChiCTR-TRC-14005182.
-
5.
On-Ticagrelor Platelet Reactivity and Clinical Outcome in Patients Undergoing Percutaneous Coronary Intervention for Acute Coronary Syndrome.
Laine, M, Panagides, V, Frère, C, Cuisset, T, Gouarne, C, Jouve, B, Lemesle, G, Paganelli, F, Alessi, MC, Mancini, J, et al
Thrombosis and haemostasis. 2021;(7):923-930
Abstract
BACKGROUND A strong association between on-thienopyridine platelet reactivity (PR) and the risk of both thrombotic and bleeding events in acute coronary syndrome (ACS) patients undergoing percutaneous coronary intervention (PCI) has been demonstrated. However, no study has analyzed the relationship between on-ticagrelor PR and clinical outcome in this clinical setting. OBJECTIVES We aimed to investigate the relationship between on-ticagrelor PR, assessed by the vasodilator-stimulated phosphoprotein (VASP) index, and clinical outcome in patients with ACS undergoing PCI. METHODS We performed a prospective, multicenter, observational study of patients undergoing PCI for ACS. PR was measured using the VASP index following ticagrelor loading dose. The primary study endpoint was the rate of Bleeding Academic Research Consortium (BARC) type ≥2 at 1 year. The key secondary endpoint was the rate of major adverse cardiovascular events (MACE) defined as the composite of cardiovascular death, myocardial infarction, stroke, and urgent revascularization. RESULTS We included 570 ACS patients, among whom 33.9% had ST-elevation myocardial infarction. BARC type ≥2 bleeding occurred in 10.9% and MACE in 13.8%. PR was not associated with BARC ≥2 or with MACE (p = 0.12 and p = 0.56, respectively). No relationship between PR and outcomes was observed, neither when PR was analyzed quantitatively nor when it was analyzed qualitatively (low on-treatment PR [LTPR] vs. no LTPR). CONCLUSION On-ticagrelor PR measured by the VASP was not associated with bleeding or thrombotic events in ACS patients undergoing PCI. PR measured by the VASP should not be used as a surrogate endpoint in studies on ticagrelor.
-
6.
Randomized Comparison of the Polymer-Free Biolimus-Coated BioFreedom Stent With the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Orsiro Stent in an All-Comers Population Treated With Percutaneous Coronary Intervention: The SORT OUT IX Trial.
Jensen, Lisette Okkels, Maeng, M, Raungaard, B, Kahlert, J, Ellert, J, Jakobsen, L, Villadsen, AB, Veien, KT, Kristensen, SD, Ahlehoff, O, et al
Circulation. 2020;(25):2052-2063
Abstract
BACKGROUND In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention. METHODS The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial. The primary end point, major adverse cardiovascular events, was defined as the composite of cardiac death, myocardial infarction not related to any segment other than the target lesion, or target lesion revascularization within 1 year, analyzed by intention-to-treat. The trial was powered to assess noninferiority for major adverse cardiovascular events of the BioFreedom stent compared with the Orsiro stent with a predetermined noninferiority margin of 0.021. RESULTS Between December 14, 2015 and April 21, 2017, 3151 patients were assigned to treatment with the BioFreedom stent (1572 patients, 1966 lesions) or to the Orsiro stent (1579 patients, 1985 lesions). Five patients were lost to follow-up because of emigration (99.9% follow-up rate). Mean age was 66.3±10.9, diabetes mellitus was seen in 19.3% of patients, and 53% of the patients had acute coronary syndromes. At 1 year, intention-to-treat analysis showed that 79 (5.0%) patients, who were assigned the BioFreedom stent, and 59 (3.7%), who were assigned the Orsiro stent, met the primary end point (absolute risk difference 1.29% [upper limit of one-sided 95% CI 2.50%]; Pnoninferiority=0.14). Significantly more patients in the BioFreedom stent group had target lesion revascularization than those in the Orsiro stent group (55 [3.5%] vs 20 [1.3%], rate ratio 2.77 [95% CI, 1.66-4.62]; P<0.0001). CONCLUSIONS The biolimus A9-coated BioFreedom polymer-free stent did not meet criteria for noninferiority for major adverse cardiovascular events at 12 months when compared with the ultrathin strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02623140.
-
7.
Impact of large periprocedural myocardial infarction on mortality after percutaneous coronary intervention and coronary artery bypass grafting for left main disease: an analysis from the EXCEL trial.
Ben-Yehuda, O, Chen, S, Redfors, B, McAndrew, T, Crowley, A, Kosmidou, I, Kandzari, DE, Puskas, JD, Morice, MC, Taggart, DP, et al
European heart journal. 2019;(24):1930-1941
Abstract
AIMS: The prognostic implications of periprocedural myocardial infarction (PMI) after percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) remain controversial. We examined the 3-year rates of mortality among patients with and without PMI undergoing left main coronary artery intervention randomized to PCI with everolimus-eluting stents vs. CABG in the large-scale, multicentre, prospective, randomized EXCEL trial. METHODS AND RESULTS By protocol, PMI was defined using an identical threshold for PCI and CABG [creatinine kinase-MB (CK-MB) elevation >10× the upper reference limit (URL) within 72 h post-procedure, or >5× URL with new Q-waves, angiographic vessel occlusion, or loss of myocardium on imaging]. Cox proportional hazards modelling was performed controlling for age, sex, hypertension, diabetes mellitus, left ventricular ejection fraction, SYNTAX score, and chronic obstructive pulmonary disease (COPD). A total of 1858 patients were treated as assigned by randomization. Periprocedural MI occurred in 34/935 (3.6%) of patients in the PCI group and 56/923 (6.1%) of patients in the CABG group [odds ratio 0.61, 95% confidence interval (CI) 0.40-0.93; P = 0.02]. Periprocedural MI was associated with SYNTAX score, COPD, cross-clamp duration and total procedure duration, and not using antegrade cardioplegia. By multivariable analysis, PMI was associated with cardiovascular death and all-cause death at 3 years [adjusted hazard ratio (HR) 2.63, 95% CI 1.19-5.81; P = 0.02 and adjusted HR 2.28, 95% CI 1.22-4.29; P = 0.01, respectively]. The effect of PMI was consistent for PCI and CABG for cardiovascular death (Pinteraction = 0.56) and all-cause death (Pinteraction = 0.59). Peak post-procedure CK-MB ≥10× URL strongly predicted mortality, whereas lesser degrees of myonecrosis were not associated with prognosis. CONCLUSION In the EXCEL trial, PMI was more common after CABG than PCI, and was strongly associated with increased 3-year mortality after controlling for potential confounders. Only extensive myonecrosis (CK-MB ≥10× URL) was prognostically important.
-
8.
Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (BIOSTEMI): a single-blind, prospective, randomised superiority trial.
Iglesias, JF, Muller, O, Heg, D, Roffi, M, Kurz, DJ, Moarof, I, Weilenmann, D, Kaiser, C, Tapponnier, M, Stortecky, S, et al
Lancet (London, England). 2019;(10205):1243-1253
Abstract
BACKGROUND Newer-generation drug-eluting stents that combine ultrathin strut metallic platforms with biodegradable polymers might facilitate vascular healing and improve clinical outcomes in patients with acute myocardial infarction undergoing primary percutaneous coronary intervention (PCI) compared with contemporary thin strut second-generation drug-eluting stents. We did a randomised clinical trial to investigate the safety and efficacy of ultrathin strut biodegradable polymer sirolimus-eluting stents versus thin strut durable polymer everolimus-eluting stents in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary PCI. METHODS The BIOSTEMI trial was an investigator-initiated, multicentre, prospective, single-blind, randomised superiority trial at ten hospitals in Switzerland. Patients aged 18 years or older with acute STEMI who were referred for primary PCI were eligible to participate. Patients were randomly allocated (1:1) to either biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Central randomisation was done based on a computer-generated allocation sequence with variable block sizes of 2, 4, and 6, which was stratified by centre, diabetes status, and presence or absence of multivessel coronary artery disease, and concealed using a secure web-based system. Patients and treating physicians were aware of group allocations, whereas outcome assessors were masked to the allocated stent. The experimental stent (Orsiro; Biotronik; Bülach, Switzerland) consisted of an ultrathin strut cobalt-chromium metallic stent platform releasing sirolimus from a biodegradable polymer. The control stent (Xience Xpedition/Alpine; Abbott Vascular, Abbott Park, IL, USA) consisted of a thin strut cobalt-chromium stent platform that releases everolimus from a durable polymer. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial reinfarction (Q-wave and non-Q-wave), and clinically-indicated target lesion revascularisation, within 12 months of the index procedure. All analyses were done with the individual participant as the unit of analysis and according to the intention-to-treat principle. The trial was registered with ClinicalTrials.gov, number NCT02579031. FINDINGS Between April 26, 2016, and March 9, 2018, we randomly assigned 1300 patients (1623 lesions) with acute myocardial infarction to treatment with biodegradable polymer sirolimus-eluting stents (649 patients and 816 lesions) or durable polymer everolimus-eluting stents (651 patients and 806 lesions). At 12 months, follow-up data were available for 614 (95%) patients treated with biodegradable polymer sirolimus-eluting stents and 626 (96%) patients treated with durable polymer everolimus-eluting stents. The primary composite endpoint of target lesion failure occurred in 25 (4%) of 649 patients treated with biodegradable polymer sirolimus-eluting stents and 36 (6%) of 651 patients treated with durable polymer everolimus-eluting stents (difference -1·6 percentage points; rate ratio 0·59, 95% Bayesian credibility interval 0·37-0·94; posterior probability of superiority 0·986). Cardiac death, target vessel myocardial reinfarction, clinically-indicated target lesion revascularisation, and definite stent thrombosis were similar between the two treatment groups in the 12 months of follow-up. INTERPRETATION In patients with acute STEMI undergoing primary PCI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 1 year. This difference was driven by reduced ischaemia-driven target lesion revascularisation in patients treated with biodegradable polymer sirolimus-eluting stents compared with durable polymer everolimus-eluting stents. FUNDING Biotronik.
-
9.
Thin composite wire strut, durable polymer-coated (Resolute Onyx) versus ultrathin cobalt-chromium strut, bioresorbable polymer-coated (Orsiro) drug-eluting stents in allcomers with coronary artery disease (BIONYX): an international, single-blind, randomised non-inferiority trial.
von Birgelen, C, Zocca, P, Buiten, RA, Jessurun, GAJ, Schotborgh, CE, Roguin, A, Danse, PW, Benit, E, Aminian, A, van Houwelingen, KG, et al
Lancet (London, England). 2018;(10154):1235-1245
Abstract
BACKGROUND During the past decade, many patients had zotarolimus-eluting stents implanted, which had circular shape cobalt-chromium struts with limited radiographic visibility. The Resolute Onyx stent was developed to improve visibility while reducing strut thickness, which was achieved by using a novel composite wire with a dense platinum-iridium core and an outer cobalt-chromium layer. We did the first randomised clinical trial to assess the safety and efficacy of this often-used stent compared with the Orsiro stent, which consists of ultrathin cobalt-chromium struts. METHODS We did an investigator-initiated, assessor-blinded and patient-blinded, randomised non-inferiority trial in an allcomers population at seven independently monitored centres in Belgium, Israel, and the Netherlands. Eligible participants were aged 18 years or older and required percutaneous coronary intervention with drug-eluting stents. After guide wire passage with or without predilation, members of the catheterisation laboratory team used web-based computer-generated allocation sequences to randomly assign patients (1:1) to either the Resolute Onyx or the Orsiro stent. Randomisation was stratified by sex and diabetes status. Patients and assessors were masked to allocated stents, but treating clinicians were not. The primary endpoint was target vessel failure at 1 year, a composite of cardiac death, target-vessel-related myocardial infarction, and target vessel revascularisation, and was assessed by intention to treat (non-inferiority margin 2·5%) on the basis of outcomes adjudicated by an independent event committee. This trial is registered with ClinicalTrials.gov, number NCT02508714. FINDINGS Between Oct 7, 2015, and Dec 23, 2016, 2516 patients were enrolled, 2488 of whom were included in the intention-to-treat analysis (28 withdrawals or screening failures). 1243 participants were assigned to the Resolute Onyx group, and 1245 to the Orsiro group. Overall, 1765 (70·9%) participants presented with acute coronary syndromes and 1275 (51·2%) had myocardial infarctions. 1-year follow-up was available for 2478 (99·6%) patients. The primary endpoint was met by 55 (4·5%) patients in the Resolute Onyx group and 58 (4·7%) in the Orsiro group. Non-inferiority of Resolute Onyx to Orsiro was thus established (absolute risk difference -0·2% [95% CI -1·9 to 1·4]; upper limit of the one-sided 95% CI 1·1%; pnon-inferiority=0·0005). Definite or probable stent thrombosis occurred in one (0·1%) participant in the Resolute Onyx group and nine (0·7%) in the Orsiro group (hazard ratio 0·11 [95% CI 0·01-0·87]; p=0·0112). INTERPRETATION The Resolute Onyx stent was non-inferior to Orsiro for a combined safety and efficacy endpoint at 1-year follow-up in allcomers. The low event rate in both groups suggests that both stents are safe, and the very low rate of stent thrombosis in the Resolute Onyx group warrants further clinical investigation. FUNDING Biotronik and Medtronic.
-
10.
Comparison of Fractional FLow Reserve And Intravascular ultrasound-guided Intervention Strategy for Clinical OUtcomes in Patients with InteRmediate Stenosis (FLAVOUR): Rationale and design of a randomized clinical trial.
Kang, J, Koo, BK, Hu, X, Lee, JM, Hahn, JY, Yang, HM, Shin, ES, Nam, CW, Doh, JH, Lee, BK, et al
American heart journal. 2018;:7-12
Abstract
BACKGROUND Coronary angiography has limitations in defining the ischemia-causing stenotic lesion, especially in cases with intermediate coronary stenosis. Fractional flow reserve (FFR) is a current standard method to define the presence of ischemia, and intravascular ultrasound (IVUS) is the most commonly used invasive imaging tool that can provide the lesion geometry and can provide the information on plaque vulnerability. The primary aim of this study is to compare the safety and efficacy of FFR-guided and IVUS-guided percutaneous coronary intervention (PCI) strategies in patients with intermediate coronary stenosis. TRIAL DESIGN Comparison of Fractional FLow Reserve And Intravascular ultrasound-guided Intervention Strategy for Clinical OUtcomes in Patients with InteRmediate Stenosis (FLAVOUR) trial is an international, multicenter, prospective, randomized clinical trial. A total of 1,700 consecutive patients with intermediate stenosis (40%-70% by visual estimation) in a major epicardial coronary artery will be randomized 1:1 to receive either FFR-guided or IVUS-guided PCI strategy. Patients will be treated with PCI according to the predefined criteria for revascularization; FFR ≤ 0.80 in the FFR-guided group and Minimal Lumen Area (MLA) ≤3 mm2 (or 3 mm270%) in the IVUS-guided group. The primary end point is the patient-oriented composite outcome, which is a composite of all-cause death, myocardial infarction, and any repeat revascularization at 24months after randomization. We will test noninferiority of current standard FFR-guided PCI strategy compared with IVUS-guided decision for PCI and stent optimization strategy. CONCLUSION The FLAVOUR trial will compare the safety and efficacy of FFR- and IVUS-guided PCI strategies in patients with intermediate coronary stenosis. This study will provide an insight on optimal evaluation and treatment strategy for patients with intermediate coronary stenosis.