-
1.
Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis.
Cantoni, V, Green, R, Acampa, W, Zampella, E, Assante, R, Nappi, C, Gaudieri, V, Mannarino, T, Cuocolo, R, Di Vaia, E, et al
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2021;(2):698-715
Abstract
BACKGROUND We performed a meta-analysis to compare the diagnostic performance of conventional SPECT (C-SPECT) and cadmium-zinc-telluride (CZT)-SPECT systems in detecting angiographically proven coronary artery disease (CAD). METHODS Studies published between January 2000 and February 2018 were identified by database search. We included studies assessing C-SPECT or CZT-SPECT as a diagnostic test to evaluate patients for the presence of CAD, defined as at least 50% diameter stenosis on invasive coronary angiography. A study was eligible regardless of whether patients were referred for suspected or known CAD. RESULTS We identified 40 eligible articles (25 C-SPECT and 15 CZT-SPECT studies) including 7334 patients (4997 in C-SPECT and 2337 in CZT-SPECT studies). The pooled sensitivity and specificity were 85% and 66% for C-SPECT and 89% and 69% for CZT-SPECT imaging studies. The area under the curve was slightly higher for CZT-SPECT (0.89) compared to C-SPECT (0.83); accordingly, the summary diagnostic OR was 17 for CZT-SPECT and 11 for C-SPECT. The accuracy of the two tests slightly differs between C-SPECT and CZT-SPECT (chi-square 11.28, P < .05). At meta-regression analysis, no significant association between both sensitivity and specificity and demographical and clinical variables considered was found for C-SPECT and CZT-SPECT studies. CONCLUSIONS C-SPECT and CZT-SPECT have good diagnostic performance in detecting angiographic proven CAD, with a slightly higher accuracy for CZT-SPECT. This result supports the use of the novel gamma cameras in clinical routine practices also considering the improvements in acquisition time and radiation exposure reduction.
-
2.
The value of four imaging modalities to distinguish malignant from benign solitary pulmonary nodules: a study based on 73 cohorts incorporating 7956 individuals.
Wu, Q, Zhong, L, Xie, X
Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico. 2021;(2):296-310
Abstract
BACKGROUND Solitary pulmonary nodules (SPNs) frequently bother oncologists. The differentiation of malignant from benign nodules with non-invasive approach remains a tough challenge. This study was designed to assess the diagnostic accuracy of dynamic computed tomography (CT), dynamic magnetic resonance imaging (MRI), fluorine 18 fluorodeoxyglucose (18F-FDG) positron emission tomography (PET), and technetium 99 m (99mTc) depreotide single photon emission computed tomography (SPECT) for SPNs. METHODS Electronic databases of MEDLINE, PubMed, EMBASE, and Cochrane Library were searched to identify relevant trials. The primary evaluation index of diagnostic accuracy was areas under the summary receiver-operating characteristic (SROC) curve. The results were analyzed utilizing Stata 12.0 statistical software. RESULTS Seventy-three trials incorporating 7956 individuals were recruited. Sensitivities, specificities, positive likelihood ratios, negative likelihood ratios, diagnostic score, diagnostic odds ratios, and areas under the SROC curve with 95% confidence intervals were, respectively, 0.92 (0.89-0.95), 0.64 (0.54-0.74), 2.60 (1.98-3.42), 0.12 (0.08-0.17), 3.10 (2.62-3.59), 22.24 (13.67-36.17), and 0.91 (0.88-0.93) for CT; 0.92 (0.86-0.95), 0.85 (0.77-0.90), 6.01 (3.90-9.24), 0.10 (0.06-0.17), 4.12 (3.41-4.82), 61.39 (30.41-123.93), and 0.94 (0.92-0.96) for MRI; 0.90 (0.86-0.93), 0.73 (0.65-0.79), 3.28 (2.56-4.20), 0.14 (0.10-0.19), 3.16 (2.69-3.64), 23.68 (14.74-38.05), and 0.90 (0.87-0.92) for 18F-FDG PET; and 0.93 (0.88-0.96), 0.70 (0.56-0.81), 3.12 (2.03-4.81), 0.10 (0.06-0.17), 3.43 (2.63-4.22), 30.74 (13.84-68.27), and 0.93 (0.91-0.95) for 99mTc-depreotide SPECT. CONCLUSION The dynamic MRI, dynamic CT, 18F-FDG PET, and 99mTc-depreotide SPECT were favorable non-invasive approaches to distinguish malignant SPNs from benign. Moreover, from the viewpoint of cost-effectiveness and avoiding radiation, the dynamic MRI was recommendable for SPNs.
-
3.
Upfront F18-choline PET/CT versus Tc99m-sestaMIBI SPECT/CT guided surgery in primary hyperparathyroidism: the randomized phase III diagnostic trial APACH2.
Quak, E, Lasne Cardon, A, Ciappuccini, R, Lasnon, C, Bastit, V, Le Henaff, V, Lireux, B, Foucras, G, Jaudet, C, Berchi, C, et al
BMC endocrine disorders. 2021;(1):3
Abstract
BACKGROUND The common endocrine disorder primary hyperparathyroidism (PHPT) can be cured by surgery. Preoperative localization of parathyroid adenoma (PTA) by imaging is a prerequisite for outpatient minimally invasive parathyroidectomy (MIP). Compared to inpatient bilateral cervical exploration (BCE) which is performed if imaging is inconclusive, MIP is superior in terms of cure and complication rates and less costly. The imaging procedure F18-choline (FCH) PET/CT outperforms Tc99m-sestaMIBI (MIBI) SPECT/CT for PTA localization, but it is much costlier. The aim of this study is to identify the most efficient first-line imaging modality for optimal patient care in PHPT without added cost to society. METHODS We will conduct a multicenter open diagnostic intervention randomized phase III trial comparing two diagnostic strategies in patients with PHPT upfront FCH PET/CT versus MIBI SPECT/CT. The primary endpoint is the proportion of patients in whom the first-line imaging method results in successful MIP and cure. Follow-up including biological tests will be performed 1 and 6 months after surgery. The main secondary endpoint is the social cost of both strategies. Other secondary endpoints are as follows: FCH PET/CT and MIBI SPECT/CT diagnostic performance, performance of surgical procedure and complication rate, FCH PET/CT inter- and intra-observer variability and optimization of FCH PET/CT procedure. Fifty-eight patients will be enrolled and randomized 1:1. DISCUSSION FCH PET/CT is a highly efficient but expensive imaging test for preoperative PTA localization and costs three to four times more than MIBI SPECT/CT. Whether FCH PET/CT improves patient outcomes compared to the reference standard MIBI SPECT/CT is unknown. To justify its added cost, FCH PET/CT-guided parathyroid surgery should lead to improved patient management, resulting in higher cure rates and fewer BCEs and surgical complications. In the previous phase II APACH1 study, we showed that second-line FCH PET/CT led to a cure in 88% of patients with negative or inconclusive MIBI SPECT/CT. BCE could be avoided in 75% of patients and surgical complication rates were low. We therefore hypothesize that upfront FCH PET/CT would improve patient care in PHPT and that the reduction in clinical costs would offset the increase in imaging costs. TRIAL REGISTRATION NCT04040946 , registered August 1, 2019. Protocol version Version 2.1 dated from 2020/04/23.
-
4.
Clinical utility of perfusion (Q)-single-photon emission computed tomography (SPECT)/CT for diagnosing pulmonary embolus (PE) in COVID-19 patients with a moderate to high pre-test probability of PE.
Das, JP, Yeh, R, Schöder, H
European journal of nuclear medicine and molecular imaging. 2021;(3):794-799
-
-
Free full text
-
Abstract
PURPOSE We reviewed the clinical utility of perfusion (Q)-single-photon emission computed tomography (SPECT)/CT for diagnosing pulmonary embolus (PE) in patients hospitalized with severe acute respiratory syndrome coronavirus 2 (SARS-CoV2). METHODS Following the World Health Organization's declaration of a global pandemic, our department policy recommended Q-only SPECT/CT for all patients undergoing nuclear medicine evaluation for suspected PE to reduce the risk of aerosolization of respiratory droplets. We performed a retrospective review of sequential patients admitted with COVID-19 imaged with Q-SPECT/CT between March 17, 2020, and June 30, 2020, at Memorial Sloan Kettering Cancer Center. We recorded patient demographics, clinical symptoms, Wells score (to stratify patients according to pre-test probability for PE prior to Q-SPECT/CT), and noted ancillary imaging findings on CT. RESULTS Of the 33 patients imaged with Q-SPECT/CT, 6 patients (3 men, 3 women) had a laboratory confirmed diagnosis of COVID-19 (mean age, 55, ± 11.4 years, range 33-68). All patients had a current diagnosis of malignancy and had a moderate or high pre-test probability for PE (mean Wells score 2.8, range 2-4). Q-SPECT/CT was positive in 4/6 (67%) of patients. Distribution of pulmonary emboli was bilateral and segmental in 75% of patients. Ancillary acute findings on SPECT/CT included bilateral parenchymal ground glass opacities (n = 5), pleural effusions (n = 2), and pneumomediastinum (n = 1). CONCLUSION Q-SPECT/CT has clinical utility for diagnosing PE in patients with COVID-19 where there is a contraindication for iodinated contrast media and a moderate or high pre-test probability for PE.
-
5.
Pulmonary perfusion by iodine subtraction maps CT angiography in acute pulmonary embolism: comparison with pulmonary perfusion SPECT (PASEP trial).
Dissaux, B, Le Floch, PY, Robin, P, Bourhis, D, Couturaud, F, Salaun, PY, Nonent, M, Le Roux, PY
European radiology. 2020;(9):4857-4864
Abstract
OBJECTIVE To assess the diagnostic accuracy of iodine map computed tomography pulmonary angiography (CTPA), for segment-based evaluation of lung perfusion in patients with acute pulmonary embolism (PE), using perfusion single-photon emission CT (SPECT) imaging as a reference standard. METHODS Thirty participants who have been diagnosed with acute pulmonary embolism on CTPA underwent perfusion SPECT/CT within 24 h. Perfusion SPECT and iodine map were independently interpreted by 2 nuclear medicine physicians and 2 radiologists. For both modalities, each segment was classified as normoperfused or hypoperfused, as defined by a perfusion defect of more than 25% of a segment. The primary end point was the diagnostic accuracy (sensitivity and specificity) of iodine map for segment-based evaluation of lung perfusion, using perfusion SPECT imaging as a reference standard. Following blinded interpretation, a retrospective explanatory analysis was performed to determine potential causes of misinterpretation. RESULTS The median time between CTPA with iodine maps and perfusion SPECT was 14 h (range 2-23 h). A total of 597 segments were analyzed. Sensitivity and specificity of iodine maps with CTPA for the detection of segmental perfusion defects were 231/284 = 81.3% (95% CI 76.4 to 85.4%) and 247/313 = 78.9% (95% CI 74.1 to 83.1%), respectively. In retrospect, false results were explained in 48.7%. CONCLUSION Iodine map CTPA showed promising results for the assessment of pulmonary perfusion in patients with acute PE, with sensitivity of 81.3% and specificity of 78.9%, respectively. Recognition of typical pitfalls such as atelectasis, fissures, or beam-hardening artifacts may further improve the accuracy of the test. KEY POINTS • Sensitivity and specificity of iodine subtraction maps for the detection of segmental perfusion defects were 81.3% (95% CI 76.4 to 85.4%) and 78.9% (95% CI 74.1 to 83.1%), respectively. • Recognition of typical pitfalls such as atelectasis, fissures, or beam-hardening artifacts may further improve the diagnostic accuracy of the test.
-
6.
The effects of pharmacological interventions, exercise, and dietary supplements on extra-cardiac radioactivity in myocardial perfusion single-photon emission computed tomography imaging.
Molavipordanjani, S, Abedi, SM, Hosseinimehr, SJ, Fatahian, A, Mardanshahi, A
Nuclear medicine communications. 2020;(9):841-847
Abstract
Myocardial perfusion imaging (MPI) as an imaging modality plays a key role in the monitoring of patients with cardiovascular disease. MPI enables the assessment of cardiovascular disease, the effectiveness of therapy, and viable myocardial tissue. However, MPI suffers from some downfalls and limitations, which can influence its clinical applications. These limitations can arise from the patient's condition, equipment, or the actions of the technologist. In this review, we mainly focused on the different effective parameters on radioactivity uptake of organs including liver, intestines, stomach, and gall bladder and how they affect the quality of the acquired images in nuclear medicine. More importantly, we cover how different suggested medicines, foods and exercise alleviative this problem.
-
7.
Intelligent Imaging: Radiomics and Artificial Neural Networks in Heart Failure.
Currie, G, Iqbal, B, Kiat, H
Journal of medical imaging and radiation sciences. 2019;(4):571-574
Abstract
BACKGROUND Our previous work with 123iodine meta-iodobenzylguanidine (123I-mIBG) radionuclide imaging among patients with cardiomyopathy reported limitations associated with the prognostic power of global parameters derived from planar imaging [1]. Employing multivariate analysis, we further showed the regional washout associated with territories adjacent to infarcted myocardium obtained from single-photon emission computed tomography imaging (SPECT) yielded superior prognostic power over the other planar and SPECT indices in predicting future cardiac events [1]. The aim of this study was to apply an artificial neural network (Neural Analyser version 2.9.5) to the original data from the same patient cohort to evaluate the most potent prognostic index for future cardiac events among patient with cardiomyopathy. METHODS The original data were reevaluated using an artificial neural network (Neural Analyser version 2.9.5). There were 84 input variables in the original 22 patients from clinical data, electrocardiogram (rest, stress, and continuous ambulatory electrocardiogram recording), transthoracic echocardiography, coronary angiogram, sestamibi myocardial perfusion SPECT, planar and SPECT 123I-mIBG, and genetic and biomarkers, detailed in the previous work. A single binary output was a cardiac event or no cardiac event in the follow-up period. RESULTS Following training and validation phases, the optimal number of inputs was determined to be two with a training loss of 0.025 and selection loss <0.001. The final architecture had inputs of a change in left ventricular ejection fraction (Δ > -10%) and 123I-mIBG planar global washout (>30%), two hidden layers of 6 and 1 node, respectively, and a binary output. Using receiver operator characteristics analysis demonstrated an area under the curve of 0.75 correlating to a sensitivity of 100% and specificity of 50%. CONCLUSION The premise that regional washout of 123I-mIBG SPECT from noninfarcted tissue is the best predictor of cardiac events was built on has a sound and logical foundation. By artificial neural network analysis; however, 123I-mIBG planar global washout of >30% was shown to be the best indicator for risk of cardiac event when accompanied by a decline in left ventricular ejection fraction of >10%. Further investigation should be undertaken assessing assimilation into big data and the potential for automated feature extraction from raw image datasets with convolutional neural networks.
-
8.
Assessment of Myocardial CZT SPECT Recording in a Forward-Leaning Bikerlike Position.
Perrin, M, Roch, V, Claudin, M, Verger, A, Boutley, H, Karcher, G, Baumann, C, Veran, N, Marie, PY, Imbert, L
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2019;(6):824-829
Abstract
This prospective randomized study assessed myocardial perfusion imaging with the high-sensitivity D.SPECT cadmium-zinc-telluride camera in a forward-leaning bikerlike position, which may potentially lower diaphragmatic attenuation and reduce breathing-related cardiac motion, in a manner comparable to the prone position proposed with other SPECT cameras. Methods: Patients referred for a stress-rest 99mTc-sestamibi protocol and positioned in the biker position, with the chest leaning forward on the D.SPECT camera-head at 35° from vertical, had an additional resting D.SPECT recording in the supine position (n = 40) or in the sitting position with the back rearward at 30° from vertical (n = 40). Segments with attenuation artifacts were defined as those with less than 65% uptake but with strictly normal contractility at gated SPECT and no defect reversibility from stress images. Results: The biker position was associated with lower heart-to-detector distances than the supine or sitting positions (both P < 0.001); lower cardiac motion amplitudes, assessed on panograms, than the supine position (P < 0.001); and fewer segments with attenuation artifacts than the supine position (on average, 1.10 ± 1.01 vs. 1.90 ± 1.74, P = 0.010) or the sitting position (0.75 ± 0.93 vs. 1.38 ± 1.60, P = 0.011). Conclusion: Myocardial perfusion images from D.SPECT are enhanced for patients positioned in a forward-leaning bikerlike position comparatively to sitting or supine positions, with a notably lower rate of attenuation artifacts.
-
9.
Optimizing the Diagnosis of Parkinsonian Syndromes With 123I-Ioflupane Brain SPECT.
Banks, KP, Peacock, JG, Clemenshaw, MN, Kuo, PH
AJR. American journal of roentgenology. 2019;(2):243-253
Abstract
OBJECTIVE. The purpose of this article is to provide a review of 123I-ioflupane SPECT in the evaluation of suspected parkinsonian syndromes (PSs). This collection of diseases presents frequent diagnostic challenges, even by movement disorder and dementia specialists. CONCLUSION. The 123I-ioflupane scan serves as an imaging biomarker of the status of presynaptic dopamine transporters (DATs) in the striatum. As a result of neuronal death, DATs are greatly reduced in patients with PS neurodegenerative disorders, whereas clinical mimics generally do not show striatal DAT loss. This provides a tremendous opportunity for 123I-ioflupane to aid in the accurate and timely diagnosis of these patients and optimize their management.
-
10.
123I-ioflupane SPET and 123I-MIBG in the diagnosis of Parkinson's disease and parkinsonian disorders and in the differential diagnosis between Alzheimer's and Lewy's bodies dementias.
Nuvoli, S, Palumbo, B, Malaspina, S, Madeddu, G, Spanu, A
Hellenic journal of nuclear medicine. 2018;(1):60-68
Abstract
Nuclear medicine procedures are widely used as "in vivo" biomarkers in a large number of brain diseases, especially in the diagnosis of Parkinson's disease (PD) and of parkinsonian disorders (pD). Furthermore, nuclear medicine is used in the differential diagnosis of dementias especially Alzheimer's disease (AD) and dementia with Lewy's bodies (LBD) which share many clinical symptoms and often LBD is misdiagnosed as AD. The differential diagnosis between these clinical entities is crucial for treatment since LBD also shares some clinical symptoms with parkinsonian disorders. We reviewed the most relevant papers that study the usefulness of both iodine-123-ioflupane studied by single photon emission tomography (123I-ioflupane SPET) and of 123I-metaiodobenzylguanidine (123I-MIBG) cardiac scintigraphy in the diagnosis of PD and pD and in the differential diagnosis between AD and LBD in order to contribute to the clinical practice of the diseases.