1.
Deep Learning-Based Quantification of Epicardial Adipose Tissue Volume and Attenuation Predicts Major Adverse Cardiovascular Events in Asymptomatic Subjects.
Eisenberg, E, McElhinney, PA, Commandeur, F, Chen, X, Cadet, S, Goeller, M, Razipour, A, Gransar, H, Cantu, S, Miller, RJH, et al
Circulation. Cardiovascular imaging. 2020;(2):e009829
-
-
Free full text
-
Abstract
BACKGROUND Epicardial adipose tissue (EAT) volume (cm3) and attenuation (Hounsfield units) may predict major adverse cardiovascular events (MACE). We aimed to evaluate the prognostic value of fully automated deep learning-based EAT volume and attenuation measurements quantified from noncontrast cardiac computed tomography. METHODS Our study included 2068 asymptomatic subjects (56±9 years, 59% male) from the EISNER trial (Early Identification of Subclinical Atherosclerosis by Noninvasive Imaging Research) with long-term follow-up after coronary artery calcium measurement. EAT volume and mean attenuation were quantified using automated deep learning software from noncontrast cardiac computed tomography. MACE was defined as myocardial infarction, late (>180 days) revascularization, and cardiac death. EAT measures were compared to coronary artery calcium score and atherosclerotic cardiovascular disease risk score for MACE prediction. RESULTS At 14±3 years, 223 subjects suffered MACE. Increased EAT volume and decreased EAT attenuation were both independently associated with MACE. Atherosclerotic cardiovascular disease risk score, coronary artery calcium, and EAT volume were associated with increased risk of MACE (hazard ratio [95%CI]: 1.03 [1.01-1.04]; 1.25 [1.19-1.30]; and 1.35 [1.07-1.68], P<0.01 for all) and EAT attenuation was inversely associated with MACE (hazard ratio, 0.83 [95% CI, 0.72-0.96]; P=0.01), with corresponding Harrell C statistic of 0.76. MACE risk progressively increased with EAT volume ≥113 cm3 and coronary artery calcium ≥100 AU and was highest in subjects with both (P<0.02 for all). In 1317 subjects, EAT volume was correlated with inflammatory biomarkers C-reactive protein, myeloperoxidase, and adiponectin reduction; EAT attenuation was inversely related to these biomarkers. CONCLUSIONS Fully automated EAT volume and attenuation quantification by deep learning from noncontrast cardiac computed tomography can provide prognostic value for the asymptomatic patient, without additional imaging or physician interaction.
-
2.
Can radiomics help to predict skeletal muscle response to chemotherapy in stage IV non-small cell lung cancer?
de Jong, EEC, Sanders, KJC, Deist, TM, van Elmpt, W, Jochems, A, van Timmeren, JE, Leijenaar, RTH, Degens, JHRJ, Schols, AMWJ, Dingemans, AC, et al
European journal of cancer (Oxford, England : 1990). 2019;:107-113
Abstract
BACKGROUND Muscle depletion negatively impacts treatment efficacy and survival rates in cancer. Prevention and timely treatment of muscle loss require prediction of patients at risk. We aimed to investigate the potential of skeletal muscle radiomic features to predict future muscle loss. METHODS A total of 116 patients with stage IV non-small cell lung cancer included in a randomised controlled trial (NCT01171170) studying the effect of nitroglycerin added to paclitaxel-carboplatin-bevacizumab were enrolled. In this post hoc analysis, muscle cross-sectional area and radiomic features were extracted from computed tomography images obtained before initiation of chemotherapy and shortly after administration of the second cycle. For internal cross-validation, the cohort was randomly split in a training set and validation set 100 times. We used least absolute shrinkage and selection operator method to select features that were most significantly associated with muscle loss and an area under the curve (AUC) for model performance. RESULTS Sixty-nine patients (59%) exhibited loss of skeletal muscle. One hundred ninety-three features were used to construct a prediction model for muscle loss. The average AUC was 0.49 (95% confidence interval [CI]: 0.36, 0.62). Differences in intensity and texture radiomic features over time were seen between patients with and without muscle loss. CONCLUSIONS The present study shows that skeletal muscle radiomics did not predict future muscle loss during chemotherapy in non-small cell lung cancer. Differences in radiomic features over time might reflect myosteatosis. Future imaging analysis combined with muscle tissue analysis in patients and in experimental models is needed to unravel the biological processes linked to the radiomic features.
-
3.
Evaluating the effectiveness of computed tomography-guided 125I seed interstitial implantation in patients with secondary adrenal carcinoma.
Lin, ZY, Yang, JY, Chen, J, Chen, J
Journal of cancer research and therapeutics. 2019;(4):813-817
-
-
Free full text
-
Abstract
AIM: This study aimed to evaluate the feasibility, safety, and clinical efficacy of computed tomography (CT)-guided 125 I seed interstitial implantation in patients with secondary adrenal carcinoma. MATERIALS AND METHODS Twenty patients with secondary adrenal carcinoma received CT-guided 125 I seed interstitial implantation. A three-dimensional treatment planning system was used to calculate the dose distribution before 125 I seed interstitial implantation. CT scans were performed every 2 months after the treatment to evaluate local therapeutic efficacy according to the Response Evaluation Criteria in Solid Tumors. RESULTS The mean follow-up time was 23.65 months (5-102 months). The mean maximum tumor diameter was 34.16 ± 18.94 mm at the beginning of follow-up and 14.42 ± 24.07 mm at the end of follow-up. Eleven patients had complete response (CR), seven had partial response (PR), one had stable disease, and one had progressive disease. Local control rate (CR + PR) was 90% (18/20). The median survival time was 19 months (5-71 months). The 1-, 2-, 3-, and 5-year overall survival rates were 83.70%, 46.8%, 20.80%, and 20.80%, respectively. CONCLUSION CT-guided 125 I radioactive seed interstitial implantation may be a feasible, safe, effective, and minimally invasive treatment for secondary adrenal carcinoma.
-
4.
The prognostic value of early onset, CT derived loss of muscle and adipose tissue during chemotherapy in metastatic non-small cell lung cancer.
Degens, JHRJ, Sanders, KJC, de Jong, EEC, Groen, HJM, Smit, EF, Aerts, JG, Schols, AMWJ, Dingemans, AC
Lung cancer (Amsterdam, Netherlands). 2019;:130-135
Abstract
OBJECTIVES To evaluate the relationship between early changes in muscle and adipose tissue during chemotherapy and overall survival (OS) in stage IV non-small cell lung cancer (NSCLC). MATERIALS AND METHODS In this post-hoc analysis of the first line NVALT12 trial (NCT01171170) in stage IV NSCLC, skeletal muscle (SM), radiation attenuation (RA), subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) were assessed at the third lumbar level on CT-images obtained before initiation of chemotherapy and shortly after administration of the second cycle. The contribution of changes in different body compartments to overall survival was assessed. RESULTS CT scans of 111 patients were included. Analysis of body composition changes between the baseline and the follow-up scan, revealed that overall SM cross sectional area (CSA), radiation attenuation and SAT CSA decreased respectively by -1.2 ± 2.9 cm2/m2 (p < 0.001), -0.7 ± 3.3 HU (p = 0.026) and -1.9 ± 8.7 cm2/m2 (p = 0.026), while no significant changes in VAT tissue were observed. Longitudinally, median OS was significantly shorter among patients losing SM compared to patients with preserved SM (9.4 versus 14.2 months; HR 1.9, 95% CI: 1.23, 2.79, p = 0.003). Multivariate analyses showed that proportional loss of muscle mass was associated with poor OS (HR 0.949, 95% CI: 0.915, 0.985, p = 0.006) independent from important clinical prognostic factors including WHO-PS, gender, age and Charlson comorbidity index. CONCLUSION Early loss of SM during first line chemotherapy is a poor prognostic factor in stage IV NSCLC patients. Future studies have to reveal whether early supportive intervention guided by initial CT muscle response to chemotherapy can influence the wasting process and related mortality risk.
-
5.
Prognostic value of radiologically enlarged lymph nodes in patients with metastatic colorectal cancer: Subgroup findings of the randomized, open-label FIRE-3/AIO KRK0306 trial.
Hofmann, FO, Holch, JW, Heinemann, V, Ricard, I, Reiser, MF, Baumann, AB, Hesse, N, D'Anastasi, M, Modest, DP, Stintzing, S, et al
European journal of radiology. 2018;:124-129
Abstract
PURPOSE To determine the prognostic impact of radiologically enlarged lymph nodes ≥ 10 mm on the survival of patients with metastatic colorectal cancer. MATERIALS AND METHODS The prospective, randomized, open-label FIRE-3/AIO KRK0306 trial evaluated the first-line therapy of patients with KRAS exon 2 wild-type metastatic colorectal cancer with fluorouracil, folinic acid and irinotecan plus either cetuximab or bevacizumab. In the RAS wild-type population (n = 400), adequately evaluable baseline computed tomographies (n = 339) were reviewed for enlarged regional and distant lymph nodes. Their prognostic relevance was retrospectively analyzed in uni- and multivariable Cox proportional hazard regressions. RESULTS Median overall survival was 21.7 months in patients with enlarged lymph nodes and 33.2 months in patients without (hazard rate ratio [HR] = 1.61, 95% confidence interval [CI], 1.23-2.09; P < 0.001). This was confirmed in multivariable analysis (HR = 1.37, 95% CI, 1.02-1.83; P = 0.036). Progression-free survival of patients with enlarged lymph nodes showed a consistent but insignificant trend (9.9 vs. 11.1 months; HR = 1.23, 95% CI, 0.98-1.54; P = 0.072). Enlarged lymph nodes were also associated with BRAF-mutations (P = 0.004). CONCLUSION The presence of radiologically enlarged lymph nodes in baseline staging has a negative prognostic value beyond established and potential prognostic parameters.
-
6.
Phase 1-2 Study of Dual-Energy Computed Tomography for Assessment of Pulmonary Function in Radiation Therapy Planning.
Bahig, H, Campeau, MP, Lapointe, A, Bedwani, S, Roberge, D, de Guise, J, Blais, D, Vu, T, Lambert, L, Chartrand-Lefebvre, C, et al
International journal of radiation oncology, biology, physics. 2017;(2):334-343
Abstract
PURPOSE To quantify lung function according to a dual-energy computed tomography (DECT)-derived iodine map in patients treated with radiation therapy for lung cancer, and to assess the dosimetric impact of its integration in radiation therapy planning. METHODS AND MATERIALS Patients treated with stereotactic ablative radiation therapy for early-stage or intensity modulated radiation therapy for locally advanced lung cancer were prospectively enrolled in this study. A DECT in treatment position was obtained at time of treatment planning. The relative contribution of each voxel to the total lung function was based on iodine distribution. The composition of each voxel was determined on the basis of a 2-material decomposition. The DECT-derived lobar function was compared with single photon emission computed tomography/computed tomography (SPECT/CT). A functional map was integrated in the treatment planning system using 6 subvolumes of increasing iodine distribution levels. Percent lung volume receiving 5 Gy (V5), V20, and mean dose (MLD) to whole lungs (anatomic) versus functional lungs were compared. RESULTS Twenty-five patients with lung cancer, including 18 patients treated with stereotactic ablative radiation therapy and 7 patients with intensity modulated radiation therapy (locally advanced), were included. Eighty-four percent had chronic obstructive pulmonary disease. Median (range) forced expiratory volume in 1 second was 62% of predicted (29%-113%), and median diffusing capacity of the lung for carbon monoxide was 56% (39%-91%). There was a strong linear correlation between DECT- and SPECT/CT-derived lobar function (Pearson coefficient correlation r=0.89, P<.00001). Mean (range) differences in V5, V20, and MLD between anatomic and functional lung volumes were 16% (0%-48%, P=.03), 5% (1%-15%, P=.12), and 15% (1%-43%, P=.047), respectively. CONCLUSIONS Lobar function derived from a DECT iodine map correlates well with SPECT/CT, and its integration in lung treatment planning is associated with significant differences in V5 and MLD to functional lungs. Future work will involve integration of the weighted functional volume in the treatment planning system, along with integration of an iodine map for functional lung-sparing IMRT.
-
7.
Efficacy and safety of a balanced salt solution versus a 0.9% saline infusion for the prevention of contrast-induced acute kidney injury (BASIC trial): a study protocol for a randomized controlled trial.
Jo, HA, Park, S, Kim, CD, Jung, HY, Cho, JH, Cha, RH, Kang, EW, Chang, TI, Kim, S, Kim, HJ, et al
Trials. 2017;(1):461
Abstract
BACKGROUND Contrast-induced acute kidney injury (CI-AKI) is one of the most common causes of iatrogenic kidney injury and, therefore, its prevention is an important issue. However, whether the administration of 0.9% saline is the optimal prophylaxis method remains uncertain due to its supra-physiologic chloride component. In particular, recent studies suggest that chloride-restricted solutions showed superiority over 0.9% saline in several clinical settings. METHODS/DESIGN The investigators designed a multicenter randomized controlled trial to compare the efficacy of a balanced salt solution and 0.9% saline in CI-AKI prophylaxis. This study will recruit patients who are scheduled for contrast-enhanced computed tomography (CT) scans with CI-AKI prophylaxis. In this study, participants will be randomized into two study arms; the study group will receive a balanced salt solution, and the control group will receive 0.9% saline. Fluids will be administered as designated in the protocol before and after the CT scan, and an evaluation of baseline clinical status will be performed by obtaining blood and urine samples. During the follow-up visits, the incidence of CI-AKI and long-term outcomes, including the start of renal replacement therapy or all-cause mortality, will be assessed. DISCUSSION To our knowledge, this study will be the first study assessing the preventive value of a balanced salt solution over 0.9% saline for CI-AKI. If the trial shows that the balanced salt solution is as effective for CI-AKI prophylaxis as 0.9% saline, the use of the balanced salt solution could be promoted due to the reduced possibility of consequent metabolic acidosis compared to 0.9% saline. TRIALS REGISTRATION ClinicalTrials.gov, ID: NCT02799368 . Registered on 14 June 2016.
-
8.
Shaped-bolus protocol reduces contrast medium volume in abdominal CT while maintaining image quality.
Navin, P, Murray, AM, Nandikumar, K, Waldron, R, Tuohy, B, Casey, M
Clinical radiology. 2017;(3):265.e1-265.e5
Abstract
AIM: To prospectively assess whether bolus shaping to exponentially decrease the contrast medium injection rate leads to alteration in image validity or renal function. MATERIALS AND METHODS In this prospective study, patients alternatively received 100 ml contrast medium versus 75 ml via bolus shaping. Image quality was assessed via measurement of attenuation values in the aorta, liver, and spleen and also blinded subjective assessment of image sharpness, low contrast detectability, image noise, and overall quality. Renal function was assessed by change in creatinine levels up to 72 hours post-contrast medium administration. RESULTS Of 190 abdominal computed tomography (CT) studies performed in the 3-month period, 98 received the 75 ml dose. There was no significant difference in renal function or objective image quality with a significant improvement in image sharpness in the 100 ml group. CONCLUSIONS By using bolus-shaping software, it is possible to maintain objective image quality while reducing the contrast medium load to the patient. This has significant implications regarding clinical practice in decreasing cost and risks associated with iodinated contrast media.
-
9.
Adrenal and nephrogenic hypertension: an image quality study of low tube voltage, low-concentration contrast media combined with adaptive statistical iterative reconstruction.
Li, Z, Li, Q, Shen, Y, Li, A, Li, H, Liang, L, Hu, Y, Hu, X, Hu, D
International journal of clinical practice. 2016;:B29-36
Abstract
PURPOSE The aim of this study was to investigate the effect of using low tube voltage, low-concentration contrast media and adaptive statistical iterative reconstruction (ASIR) for reducing the radiation and iodine contrast doses in adrenal and nephrogenic hypertension patients. METHODS AND MATERIALS A total of 148 hypertension patients who were suspected for adrenal lesions or renal artery stenoses were assigned to two groups and. Group A (n=74) underwent a low tube voltage, low molecular weight dextran enhanced multi-detector row spiral CT (MDCT) (80 kVp, 270 mg I/mL contrast agent), and the raw data were reconstructed with standard filtered back projection (FBP) and ASIR at four different levels of blending (20%, 40%, 60% and 80%, respectively). The control group (Group B, n=74) underwent conventional MDCT (120 kVp, 370 mg I/mL contrast agent), and the data were reconstructed with FBP. The CT values, standard deviation (SD), signal-noise-ratio (SNR) and contrast-noise-ratio (CNR) were measured in the renal vessels, normal adrenal tissue, adrenal neoplasms and subcutaneous fat. The volume CT dose index (CTDIvol ) and dose length product (DLP) were recorded, and an effective dose (ED) was obtained. Two-tailed independent t-tests, paired Chi-square tests and Kappa consistency tests were used for statistical analysis of the data. RESULTS The CTDIvol , DLP and total iodine dose in group A were decreased by 47.8%, 49.0% and 26.07%, respectively, compared to group B (P<.001). In the qualitative quality analysis, the radiologists rated the 60% ASIR the highest. The mean value of noise (SD) was significantly lower in the 40%, 60% and 80% ASIR-A groups compared with FBP-B for all comparisons. Compared to FBP-B, CNR was significantly higher, with 40%, 60% and 80% ASIR in renal artery stems (P<.05). Compared with FBP-B, a significant increase in the SNR of 40%, 60%, or 80% ASIR was observed in all cases (P<.05). CONCLUSIONS Compared with conventional protocols, the use of low tube voltage, low-concentration contrast media and 60% ASIR provides similar enhancement and image quality with a reduced radiation dose and contrast iodine dose.
-
10.
Lesion Size and Iodine Quantification to Distinguish Low-Grade From High-Grade Clear Cell Renal Cell Carcinoma Using Dual-Energy Spectral Computed Tomography.
Zhao, J, Zhang, P, Chen, X, Cao, W, Ye, Z
Journal of computer assisted tomography. 2016;(5):673-7
Abstract
OBJECTIVE The aim of this study was to assess the utility of lesion size and iodine quantification using dual-energy spectral computed tomography to distinguish between low-grade and high-grade clear cell renal cell carcinomas (ccRCCs). METHODS Spectral parameters of 75 patients with pathologically proven ccRCCs who underwent preoperative dual-energy spectral computed tomography examinations were divided into low-grade and high-grade groups. Independent sample t test, receiver operating characteristic curve analysis, and Spearman rank correlation were analyzed. RESULTS The lesion size was significantly smaller, and spectral parameters were significantly higher in the low-grade ccRCC. The significant correlation (r = -0.412, P < 0.001) by the Spearman rank correlation was between the normalized iodine concentration and lesion size. The receiver operating characteristic analysis demonstrated that 0.710 was the optimal cutoff value, which yielded the following: sensitivity, 97.6%; specificity, 97.1%; positive predictive value, 97.6%; negative predictive value, 97.1%; and accuracy, 97.3%. CONCLUSIONS Iodine quantification can play an important role in distinguishing low-grade from high-grade ccRCC.