1.
PLATINUM China: a prospective, randomized investigation of the platinum chromium everolimus-eluting stent in de novo coronary artery lesions.
Gao, R, Han, Y, Yang, Y, Zhang, J, Hou, Y, Wang, H, Li, H, Fang, Q, Yu, B, Xu, B, et al
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2015;:716-23
Abstract
OBJECTIVES The PLATINUM China clinical trial evaluated the safety and effectiveness of the thin-strut, everolimus-eluting, platinum-chromium PROMUS™ Element™ stent (PtCr-EES) (Boston Scientific, Marlborough, MA) for the treatment of patients in China. BACKGROUND Clinical outcomes from the PtCr-EES have not been evaluated in patients from China, nor has it been directly compared with the second-generation stainless steel paclitaxel-eluting TAXUS Liberté stent (PES) in a randomized head-to-head trial. Methods In this prospective, multicenter, single-blind, superiority trial, patients with a single de novo atherosclerotic coronary artery lesion were randomized 1:3 to receive either the PES or PtCr-EES. The primary endpoint was in-stent late loss at 9 months. RESULTS Among 127 PES and 373 PtCr-EES patients (71.2% male; mean age 57.3 years), the primary endpoint of 9-month in-stent late loss was 0.40 ± 0.45 mm for PES versus 0.11 ± 0.36 mm for PtCr-EES (P < 0.001). In-stent % diameter stenosis was 22.20 ± 16.00% for PES versus 11.06 ± 13.86% for PtCr-EES (P < 0.001) at 9 months. The 1-year rate of death/MI was 1.6% (2/127) for PES versus 0% (0/371) for PtCr-EES (P = 0.06) and target vessel revascularization was 4.7% (6/127) for PES versus 2.7% (10/371) for PtCr-EES (P = 0.26). No stent thromboses occurred at 12 months in either group. CONCLUSIONS In the largest prospective angiographic evaluation conducted to date with this stent, the PROMUS Element PtCr-EES was superior to the TAXUS Liberté PES for the primary endpoint of late loss at 9 months, with low rates of clinical events at 1 year. Clinical follow-up will continue to 2 years.
2.
First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.
Wang, G, Sun, Z, Jin, Q, Xu, K, Li, Y, Wang, X, Ma, Y, Liu, H, Zhao, X, Wang, B, et al
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2015;:744-51
Abstract
OBJECTIVE To evaluate the preliminary safety and efficacy of the EXCEL II stent system. BACKGROUND Although the first biodegradable polymer drug-eluting stent (BP-DES), EXCEL, was launched nearly a decade ago, in-stent restenosis and stent thrombosis remain pertinent clinical problems in practice. A new cobalt-chromium BP-DES EXCEL II has been developed with the aim of improving stent safety and efficacy. METHODS Forty-five patients with single de novo native coronary lesions were enrolled and randomized to two groups in a 2:1 ratio, the 4-month follow-up group (n = 30) and the 12-month follow-up group (n = 15). All patients underwent percutaneous coronary intervention (PCI) with the EXCEL II stent system. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) were used to assess coronary vasculature at the designated 4- or 12-month follow-up. The primary outcome was major adverse cardiac events (MACE) at 30 days post-PCI. RESULTS No MACE, thrombotic events, or target lesion failure was found in the 45 patients during the 12-month follow-up. There was no significant difference (P > 0.05) between the two groups in terms of in-stent and in-segment late lumen loss (LLL). No in-stent and in-segment restenosis was found in either group. At follow-up, the ratio of >10% uncovered struts per lesion was 26.67% in the 4-month group and 0% in the 12-month group (P < 0.05). Neointimal coverage in the 12-month group was significantly better than in the 4-month group (98.58% vs. 93.51%, P < 0.01). CONCLUSIONS This first-in-man study demonstrates promising feasibility, safety, and efficacy of EXCEL II stents. These stents were found to have rapid endothelialization and low LLL rates at 4 and 12 months after implantation.
3.
A randomized comparison of novel biodegradable polymer- and durable polymer-coated cobalt-chromium sirolimus-eluting stents.
Han, Y, Xu, B, Jing, Q, Lu, S, Yang, L, Xu, K, Li, Y, Li, J, Guan, C, Kirtane, AJ, et al
JACC. Cardiovascular interventions. 2014;(12):1352-60
Abstract
OBJECTIVES The aim of this study was to investigate the hypothesis that a novel biodegradable polymer-coated, cobalt-chromium (CoCr), sirolimus-eluting stent (BP-SES) is noninferior in safety and efficacy outcomes compared with a durable polymer (DP)-SES. BACKGROUND No randomized trials have the compared safety and efficacy of BP-SES versus DP-SES on similar CoCr platforms, thereby isolating the effect of the polymer type. METHODS In this prospective, single-blind, randomized trial conducted at 32 Chinese sites, 2,737 patients eligible for coronary stenting were treated with BP- or DP-SES in a 2:1 ratio. The primary endpoint was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or clinically indicated target lesion revascularization. Secondary endpoints included TLF components, and definite/probable stent thrombosis. RESULTS At 12 months, the difference in the primary endpoint of TLF between BP-SES (6.3%) and DP-SES (6.1%) groups was 0.25% (95% confidence interval: -1.67% to 2.17%, p for noninferiority = 0.0002), demonstrating noninferiority of BP-SES to DP-SES. Individual TLF components of cardiac death (0.7% vs. 0.6%, p = 0.62), target vessel myocardial infarction (3.6% vs. 4.3%, p = 0.39), and clinically indicated target lesion revascularization (2.6% vs. 2.2%, p = 0.50) were similar, as were low definite/probable stent thrombosis rates (0.4% vs. 0.6%, p = 0.55). CONCLUSIONS In this large-scale real-world trial, BP-SES was noninferior to DP-SES for 1-year TLF. (Evaluate Safety and Effectiveness of the Tivoli ® DES and the Firebird ® DES for Treatment of Coronary Revascularization; NCT01681381).