-
1.
Ectopic Parathyroid Adenoma in Piriform Sinus: Case Report and Review of the Literature.
Connolly, MJ, Lazinski, D, Aoki, KA, McLean, L, Torres, C, Dos Santos, MP
Ear, nose, & throat journal. 2019;(1):14-17
-
-
Free full text
-
Abstract
During routine blood work, a 53-year-old female patient was noted to have asymptomatic hypercalcemia and subsequently found to have hyperparathyroidism. Localization studies for a suspected parathyroid adenoma included 99mTc Sestamibi scintigraphy, Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) study, and ultrasound of the neck, which were initially read as negative for parathyroid adenoma. A contrast-enhanced CT scan of the neck was performed to locate the suspected parathyroid adenoma and demonstrated a soft tissue lesion within the right piriform sinus. Flexible fiber optic nasolaryngoscopy revealed a submucosal lesion in the right piriform sinus. Following these findings, the initial 99mTc Sestamibi scintigraphy and SPECT/CT were reviewed with confirmation of a focal area of increased activity superior to the right thyroid lobe, corresponding to a nodule in the right piriform sinus that demonstrated increased activity on SPECT/CT. The patient was brought to the operating room for surgical management where a laryngoscope and operating microscope were utilized. The encapsulated lesion was dissected and excised in total. The parathyroid hormone and ionized calcium levels normalized postoperatively. Pathology confirmed a parathyroid adenoma. Parathyroid adenomas are the most common cause of primary hyperparathyroidism. Sixteen percent of parathyroid adenomas can be situated in an ectopic location. Ectopic parathyroid adenomas in the piriform sinus are rare with only a few previously documented cases. We document a rare case of ectopic parathyroid adenoma in the piriform sinus overlooked on initial imaging studies. These lesions can be challenging to localize, however, an understanding of embryology, close scrutiny of possible ectopic locations, and the application of complementary imaging techniques may prove useful for surgeons and clinicians.
-
2.
WATER II (80-150 mL) procedural outcomes.
Desai, M, Bidair, M, Bhojani, N, Trainer, A, Arther, A, Kramolowsky, E, Doumanian, L, Elterman, D, Kaufman, RP, Lingeman, J, et al
BJU international. 2019;(1):106-112
Abstract
OBJECTIVES To present early safety and feasibility data from a multicentre prospective study (WATER II) of aquablation in the treatment of symptomatic men with large-volume benign prostatic hyperplasia (BPH). METHODS Between September and December 2017, 101 men with moderate-to-severe BPH symptoms and prostate volume of 80-150 mL underwent aquablation in a prospective multicentre international clinical trial. Baseline demographics and standardized postoperative management variables were carefully recorded in a central independently monitored database. Surgeons answered analogue scale questionnaires on intra-operative technical factors and postoperative management. Adverse events up to 1 month were adjudicated by an independent clinical events committee. RESULTS The mean (range) prostate volume was 107 (80-150) mL. The mean (range) operating time was 37 (15-97) min and aquablation resection time was 8 (3-15) min. Adequate adenoma resection was achieved with a single pass in 34 patients and with additional passes in 67 patients (mean 1.8 treatment passes), all in a single operating session. Haemostasis was achieved using either a Foley balloon catheter placed in the bladder under traction (n = 98, mean duration 18 h) or direct tamponade using a balloon inflated in the prostate fossa (n = 3, mean duration 15 h). No patient required electrocautery for haemostasis at the time of the primary procedure. The mean length of stay after the procedure was 1.6 days (range same day to 6 days). The Clavien-Dindo grade ≥2 event rate observed at 1 month was 29.7%. Bleeding complications were recorded in 10 patients (9.9%) during the index procedure hospitalization prior to discharge, and included six (5.9%) peri-operative transfusions. CONCLUSIONS Aquablation is feasible and safe in treating men with men with large prostates (80-150 mL). The 6-month efficacy data are being accrued and will be presented in future publications (ClinicalTrials.gov number, NCT03123250).
-
3.
Comparing adenoma and polyp miss rates for total underwater colonoscopy versus standard CO2: a randomized controlled trial using a tandem colonoscopy approach.
Anderson, JC, Kahi, CJ, Sullivan, A, MacPhail, M, Garcia, J, Rex, DK
Gastrointestinal endoscopy. 2019;(3):591-598
-
-
Free full text
-
Abstract
BACKGROUND AND AIMS Although water exchange may improve adenoma detection compared with CO2, it is unclear whether water is a better medium to fill the lumen during withdrawal and visualize the mucosa. Total underwater colonoscopy (TUC) involves the use of water exchange with the air valve off during insertion followed by the inspection of the mucosa under water. Our goal was to compare miss rates for TUC with standard CO2 for polyps and adenomas using a tandem colonoscopy design. METHODS We randomized participants to undergo tandem colonoscopies using TUC or CO2 first. In TUC, water exchange was performed during insertion, and withdrawal was performed under water. For the CO2 colonoscopy, both insertion and withdrawal were performed with CO2. The main outcomes were miss rates for polyps and adenomas for the first examination calculated as the number of additional polyps/adenomas detected during the second examination divided by the total number of polyps/adenomas detected for both examinations. Inspection times were calculated by subtracting the time for polypectomy, and care was taken to keep the times equal for both examinations. RESULTS A total of 121 participants were randomized with 61 having CO2 first. The overall miss rate for polyps was higher for the TUC-first group (81/237; 34%) compared with the CO2-first cohort (57/264; 22%) (P = .002). In addition, the overall miss rate for all adenomas was higher for the TUC-first group (52/146; 36%) compared with the CO2 group (37/159; 23%) (P = .025). However, 1 of the 3 endoscopists had higher polyp/adenoma miss rates for CO2, but these were not statistically significant differences. The insertion time was longer for TUC than for CO2. After adjusting for times, participant characteristics, and bowel preparation, the miss rate for polyps was higher for TUC than for CO2. CONCLUSIONS We found that TUC had an overall higher polyp and adenoma miss rate than colonoscopy performed with CO2, and TUC took longer to perform. However, TUC may benefit some endoscopists, an issue that requires further study. (Clinical trial registration number: NCT03231917.).
-
4.
Different dietary fibre sources and risks of colorectal cancer and adenoma: a dose-response meta-analysis of prospective studies.
Oh, H, Kim, H, Lee, DH, Lee, A, Giovannucci, EL, Kang, SS, Keum, N
The British journal of nutrition. 2019;(6):605-615
Abstract
Dietary fibre is believed to provide important health benefits including protection from colorectal cancer. However, the evidence on the relationships with different dietary fibre sources is mixed and little is known about which fibre source provides the greatest benefits. We conducted a dose-response meta-analysis of prospective cohorts to summarise the relationships of different fibre sources with colorectal cancer and adenoma risks. Analyses were restricted to publications that reported all fibre sources (cereals, vegetables, fruits, legumes) to increase comparability between results. PubMed and Embase were searched through August 2018 to identify relevant studies. The summary relative risks (RR) and 95 % CI were estimated using a random-effects model. This analysis included a total of ten prospective studies. The summary RR of colorectal cancer associated with each 10 g/d increase in fibre intake were 0·91 (95 % CI 0·82, 1·00; I2 = 0 %) for cereal fibre, 0·95 (95 % CI 0·87, 1·03, I2 = 0 %) for vegetable fibre, 0·91 (95 % CI 0·78, 1·06, I2 = 43 %) for fruit fibre and 0·84 (95 % CI 0·63, 1·13, I2 = 45 %) for legume fibre. For cereal fibre, the association with colorectal cancer risk remained statistically significant after adjustment for folate intake (RR 0·89, 95 % CI 0·80, 0·99, I2 = 2 %). For vegetable and fruit fibres, the dose-response curve suggested evidence of non-linearity. All fibre sources were inversely associated with incident adenoma (per 10 g/d increase: RR 0·81 (95 % CI 0·54, 1·21) cereals, 0·84 (95 % CI 0·71, 0·98) for vegetables, 0·78 (95 % CI 0·65, 0·93) for fruits) but not associated with recurrent adenoma. Our data suggest that, although all fibre sources may provide some benefits, the evidence for colorectal cancer prevention is strongest for fibre from cereals/grains.
-
5.
Does Increased Adenoma Detection Reduce the Risk of Colorectal Cancer, and How Good Do We Need to Be?
Dilly, CK, Kahi, CJ
Current gastroenterology reports. 2019;(4):9
-
-
Free full text
-
Abstract
PURPOSE OF REVIEW Colorectal cancer (CRC) is largely preventable with colonoscopy and other screening modalities. However, the effectiveness of screening and surveillance depends on the quality of the colonoscopy exam. Adenoma detection rate (ADR) is the best-validated metric by which we measure individual physicians' performance. RECENT FINDINGS Recent evidence suggests that ADR benchmarks may be inappropriately low. There is proof that improving ADR leads to significant reductions in post-colonoscopy CRC (PCCRC). Two studies have demonstrated that when a colonoscopy is performed by physicians with higher ADRs, patients are less likely to have advanced adenomas on surveillance and less likely to develop or die from PCCRC. Finally, there is at least some evidence that higher ADRs do not lead to more cumulative surveillance exams. The ADR is a useful outcome measure that can provide individual endoscopists and their patients with information about the likelihood of developing PCCRC. To achieve the lowest possible PCCRC rate, we should be striving for higher ADRs. While strategies and innovations may help a bit in improving ADRs, our efforts should focus on ensuring a complete mucosal exam for each patient. Behavioral psychology theories may provide useful frameworks for studying motivating factors that drive a careful exam.
-
6.
Reduction of multitasking distractions underlies the higher adenoma detection rate of water exchange compared to air insufflation - blinded analysis of withdrawal phase videos.
Hsieh, YH, Koo, M, Tseng, CW, Yang, HW, Leung, FW
United European gastroenterology journal. 2019;(2):230-238
-
-
Free full text
-
Abstract
BACKGROUND Experts have hypothesized that a reduction of multitasking distractions and improved bowel cleanliness can explain why insertion water exchange enhances adenoma detection rate. OBJECTIVE The purpose of this study was to test the role of both distractions during withdrawal and bowel cleanliness in enhancing adenoma detection rate using coded video records of colonoscopy. METHODS The withdrawal phase of videos of 299 consecutive colonoscopies from two randomized controlled trials comparing water exchange versus air insufflation at a regional hospital in Taiwan were coded. The primary outcome was distractions; activities that preclude full attention being paid to inspection of the mucosa for polyps. A single blinded reviewer collected the data. RESULTS There were significant agreements in inter-rater reliability indexes. Compared to air insufflation, water exchange had significantly fewer distractions; higher diagnostic yield (intervention time and number), adenoma detection rate, and Boston Bowel Preparation Scale score. Water exchange had a higher withdrawal technique score (predominantly adequacy of cleaning). The association between increased adenoma detection rate and water exchange was mediated by the number of distractions and withdrawal time, but not the Boston Bowel Preparation Scale score. CONCLUSION The speculation by experts that a reduction of multitasking distractions underlies the significantly higher adenoma detection rate of water exchange is supported by the current study. Increased bowel cleanliness did not contribute to the increased adenoma detection rate by use of water exchange.
-
7.
G-EYE colonoscopy is superior to standard colonoscopy for increasing adenoma detection rate: an international randomized controlled trial (with videos).
Shirin, H, Shpak, B, Epshtein, J, Karstensen, JG, Hoffman, A, de Ridder, R, Testoni, PA, Ishaq, S, Reddy, DN, Gross, SA, et al
Gastrointestinal endoscopy. 2019;(3):545-553
Abstract
BACKGROUND AND AIMS Colorectal cancer (CRC) is largely preventable with routine screening and surveillance colonoscopy; however, interval cancers arising from precancerous lesions missed by standard colonoscopy still occur. An increased adenoma detection rate (ADR) has been found to be inversely associated with interval cancers. The G-EYE device includes a reusable balloon integrated at the distal tip of a standard colonoscope, which flattens haustral folds, centralizes the colonoscope's optics, and reduces bowel slippage. The insufflated balloon also aims to enhance visualization of the colon during withdrawal, thereby increasing the ADR. METHODS In this randomized, controlled, international, multicenter study (11 centers), patients (aged ≥50 years) referred to colonoscopy for screening, surveillance, or changes in bowel habits were randomized to undergo either balloon-assisted colonoscopy by using an insufflated balloon during withdrawal or standard high-definition colonoscopy. The primary endpoint was the ADR. RESULTS One thousand patients were enrolled between May 2014 and September 2016 to undergo colonoscopy by experienced endoscopists; 803 were finally analyzed (standard colonoscopy n = 396; balloon-assisted colonoscopy n = 407). Baseline parameters were similar in both groups. Balloon-assisted colonoscopy provided a 48.0% ADR compared with 37.5% in the standard colonoscopy group (28% increase; P = .0027). Additionally, balloon-assisted colonoscopy provided for a significant increase in detection of advanced (P = .0033) flat adenomas (P < .0001) and sessile serrated adenomas/polyps (P = .0026). CONCLUSION Balloon-assisted colonoscopy yielded a higher ADR and increased the detection of advanced, flat, and sessile serrated adenomas/polyps when compared with standard colonoscopy. Improved detection by the G-EYE device could impact the quality of CRC screening by reducing miss rates and consequently reducing interval cancer incidence. (Clinical trial registration number: NCT01917513.).
-
8.
Water exchange colonoscopy decreased adenoma miss rates compared with literature data and local data with CO2 insufflation: an observational study.
Cheng, CL, Kuo, YL, Hsieh, YH, Tang, JH, Leung, FW
BMC gastroenterology. 2019;(1):143
Abstract
BACKGROUND Reports showed adenoma miss rates (AMRs) of 22.5-27% in the right colon and 23.4-33.3% in the proximal colon. Missed lesions could contribute to postcolonoscopy cancers. Water exchange (WE) with near-complete removal of infused water during insertion increased adenoma detection rate but the impact on AMR had not been reported. We hypothesized that WE could reduce AMRs. Study 1 compared the AMRs of WE with literature data. Study 2 developed local AMR data with CO2 insufflation. METHODS The lead author attended a research seminar in 2017 on WE colonoscopy. For performance improvement, study 1 was undertaken. When data in study 1 confirmed WE produced a considerably lower AMRs in the right and proximal colon, study 2 with CO2 insufflation was performed. RESULTS Eighty-six patients completed each study. In study 1, WE removed 89% of infused water upon arrival to the cecum. The AMRs of right colon (17.5%) and proximal colon (15.5%) were considerably lower than those in the literature. Upon completion of study 2, compared with local data of CO2 insufflation, WE showed a significantly lower AMR in the right (17.5% vs. 33.8%, P = 0.034) and proximal (15.5% vs. 30.4%, P = 0.018) colon, respectively. The major limitation was that the investigation consisted of two consecutive observational studies, not a randomized controlled trial (RCT). CONCLUSIONS WE with near-complete (89%) removal of infused water during insertion significantly decreased AMRs in the right and proximal colon compared with literature data and those of CO2 insufflation in our hands. The provocative data warrant confirmation in a RCT. TRIAL REGISTRATION NCT03832322 (Retrospectively registered on February 2, 2019).
-
9.
Diagnostic application of water exchange colonoscopy: A meta-analysis of randomized controlled trials.
Xu, X, Ni, D, Lu, Y, Huang, X
The Journal of international medical research. 2019;(2):515-527
Abstract
BACKGROUND Few well-designed studies have investigated water exchange colonoscopy (WE). We performed a meta-analysis to comprehensively evaluate the clinical utility of WE based on high-quality randomized controlled trials (RCTs) and to compare the impacts of WE, water immersion colonoscopy (WI), and gas-insufflation colonoscopy. METHODS We searched the Cochrane Library, MEDLINE, Embase, PubMed, Elsevier, CNKI, VIP, and Wan Fang Data for RCTs on WE. We analyzed the results using fixed- or random-effect models according to the presence of heterogeneity. Publication bias was assessed by funnel plots. RESULTS Thirteen studies were eligible for this meta-analysis. The colonoscopic techniques included WE as the study group, and WI and air- or CO2-insufflation colonoscopy as control groups. WE was significantly superior to the control procedures in terms of adenoma detection rate, proportion of painless unsedated colonoscopy procedures, and cecal intubation rate according to odds ratios. WE was also significantly better in terms of maximal pain score and patient satisfaction score according to mean difference. CONCLUSIONS WE can remarkably improve the adenoma detection rate, proportion of painless unsedated colonoscopy procedures, patient satisfaction, and cecal intubation rate, as well as reducing the maximal pain score in patients undergoing colonoscopy.
-
10.
Video-Based Assessments of Colonoscopy Inspection Quality Correlate With Quality Metrics and Highlight Areas for Improvement.
Duloy, A, Yadlapati, RH, Benson, M, Gawron, AJ, Kahi, CJ, Kaltenbach, TR, McClure, J, Gregory, DL, Keswani, RN
Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association. 2019;(4):691-700
-
-
Free full text
-
Abstract
BACKGROUND & AIMS Adenoma detection rate (ADR) and serrated polyp detection rate (SDR) vary significantly among colonoscopists. Colonoscopy inspection quality (CIQ) is the quality with which a colonoscopist inspects for polyps and may explain some of this variation. We aimed to determine the relationship between CIQ and historical ADRs and SDRs in a cohort of colonoscopists and assess whether there is variation in CIQ components (fold examination, cleaning, and luminal distension) among colonoscopists with similar ADRs and SDRs. METHODS We conducted a prospective observational study to assess CIQ among 17 high-volume colonoscopists at an academic medical center. Over 6 weeks, we video-recorded >28 colonoscopies per colonoscopist and randomly selected 7 colonoscopies per colonoscopist for evaluation. Six raters graded CIQ using an established scale, with a maximum whole colon score of 75. RESULTS We evaluated 119 colonoscopies. The median whole-colon CIQ score was 50.1/75. Whole-colon CIQ score (r=0.71; P<.01) and component scores (fold examination r=0.74; cleaning r=0.67; distension r=0.77; all P<.01) correlated with ADR. Proximal colon CIQ score (r=0.67; P<.01) and component scores (fold examination r=0.71; cleaning r=0.62; distension r=0.65; all P<.05) correlated with SDR. CIQ component scores differed significantly between colonoscopists with similar ADRs and SDRs for most of the CIQ skills. CONCLUSION In a prospective observational study, we found CIQ and CIQ components to correlate with ADR and SDR. Colonoscopists with similar ADRs and SDRs differ in their performance of the 3 CIQ components-specific, actionable feedback might improve colonoscopy technique.