-
1.
Benefit of Contrast-Enhanced Ultrasound (CEUS) in the Follow-Up Care of Patients with Colon Cancer: A Prospective Multicenter Study.
Bernatik, T, Schuler, A, Kunze, G, Mauch, M, Dietrich, CF, Dirks, K, Pachmann, C, Börner, N, Fellermann, K, Menzel, J, et al
Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2015;(6):590-3
Abstract
PURPOSE According to the German guidelines on colorectal cancer, unenhanced ultrasound is recommended for follow-up. On the other hand, ultrasound and radiology societies specify the use of contrast-enhanced ultrasound for ruling out liver metastases. Studies focusing on the follow-up of cancer patients are lacking. The goal of this multicenter study initiated by the German Ultrasound Society (DEGUM) was to determine the potential benefit of contrast-enhanced ultrasound in the follow-up of patients with colon cancer. MATERIALS AND METHODS Follow-up patients with colon cancer (UICC > IIa) were investigated. As scheduled according to the German guidelines, unenhanced ultrasound was performed followed by contrast-enhanced ultrasound. All liver lesions were recorded. In case of additional metastases detected on contrast-enhanced ultrasound, contrast-enhanced CT, MRI or biopsy was performed to confirm additional liver metastases. RESULTS A total of 45 liver metastases were detected in 26/290 patients (= 9 %) using unenhanced ultrasound. A further 28 metastases were detected on contrast-enhanced ultrasound in these 26 patients. In 18 patients showing no liver metastases, 40 additional metastases were detected on unenhanced ultrasound. This means that 44 patients with a total of 113 liver metastases were detected on contrast-enhanced ultrasound (p = 0.0006). CONCLUSION Contrast-enhanced ultrasound should be recommended in the follow-up of patients with colon cancer in addition to unenhanced ultrasound - the up-to-date standard.
-
2.
Improved detection of hypervascular liver lesions with CAIPIRINHA-Dixon-TWIST-volume-interpolated breath-hold examination.
Kazmierczak, PM, Theisen, D, Thierfelder, KM, Sommer, WH, Reiser, MF, Notohamiprodjo, M, Nikolaou, K
Investigative radiology. 2015;(3):153-60
Abstract
OBJECTIVES The aim of this study was to assess the diagnostic performance of a dynamic, multiphasic contrast-enhanced volume-interpolated sequence with advanced parallel imaging techniques, Dixon fat saturation, and view sharing with 5 hepatic arterial subphases for the detection of focal liver lesions. MATERIALS AND METHODS Twenty-four consecutive patients (13 females, 11 males; mean [SD] age, 58 [15] years) with focal liver lesions were included in this prospective study. The examination was performed at a 3-T magnetic resonance imaging system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). Five dynamic arterial subphases with a temporal resolution of 2.6 seconds, starting 17 seconds after injection of the hepatobiliary contrast agent gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Eovist; Bayer HealthCare, Leverkusen, Germany), were acquired using an accelerated parallel imaging volume-interpolated sequence with view sharing (multiarterial controlled aliasing in parallel imaging results in higher acceleration-Dixon-time-resolved angiography with interleaved stochastic trajectories-volumetric interpolated breath-hold examination [MA-CDT-VIBE]). The fourth of the 5 arterial acquisition phases (ie, at 24.8 seconds after the start of contrast agent injection) was considered the equivalent of a standard hepatic arterial phase (equivalent standard arterial phase [ESAP]). The diagnostic value of all 5 dynamic arterial phases for the detection of focal liver lesions, as compared with the single ESAP, was judged in 2 independent consensus readings. The 2 consensus reading groups were blinded to each others' results. The complete, comprehensive multisequence magnetic resonance imaging examination, including T1-weighted, T2-weighted, and multiphasic contrast-enhanced sequences, served as the standard of reference for lesion detection. RESULTS Forty-six percent of the patients (11/24) had hypervascular lesions. In 79 % of all patients (19/24), the best arterial parenchymal contrast of one of the MA-CDT-VIBE acquisition phases was considered better than that of the ESAP. In one third of all cases (8/24 for the first and 6/24 for the second consensus reading), MA-CDT-VIBE showed an improved lesion detection rate compared with ESAP, especially in hypervascular lesions (4/11, representing 36% of all patients with hypervascular lesions). There was a high degree of interrater agreement between the 2 consensus reading groups (the Cohen κ, 0.71-1.00; P < 0.001). CONCLUSIONS Compared with a standard hepatic arterial phase, MA-CDT-VIBE with 5 hepatic arterial subphases demonstrated greater diagnostic accuracy for the detection of hypervascular focal liver lesions and provided a robust and optimized hepatic arterial acquisition phase.
-
3.
Evaluation of monoenergetic late iodine enhancement dual-energy computed tomography for imaging of chronic myocardial infarction.
Wichmann, JL, Arbaciauskaite, R, Kerl, JM, Frellesen, C, Bodelle, B, Lehnert, T, Monsefi, N, Vogl, TJ, Bauer, RW
European radiology. 2014;(6):1211-8
Abstract
OBJECTIVES To evaluate image quality and diagnostic accuracy of selective monoenergetic reconstructions of late iodine enhancement (LIE) dual-energy computed tomography (DECT) for imaging of chronic myocardial infarction (CMI). METHODS Twenty patients with a history of coronary bypass surgery underwent cardiac LIE-DECT and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI). LIE-DECT images were reconstructed as selective monoenergetic spectral images with photon energies of 40, 60, 80, and 100 keV and the standard linear blending setting (M_0.6). Images were assessed for late enhancement, transmural extent, signal characteristics and subjective image quality. RESULTS Seventy-nine myocardial segments (23 %) showed LGE. LIE-DECT detected 76 lesions. Images obtained at 80 keV and M_0.6 showed a high signal-to-noise ratio (15.9; 15.1), contrast-to-noise ratio (4.2; 4.0) and sensitivity (94.9 %; 92.4 %) while specificity was identical (99.6 %). Differences between these series were not statistically significant. Transmural extent of LIE was overestimated in both series (80 keV: 40 %; M_0.6: 35 %) in comparison to MRI. However, observers preferred 80 keV in 13/20 cases (65 %, κ = 0.634) over M_0.6 (4/20 cases) regarding subjective image quality. CONCLUSIONS Post-processing of LIE-DECT data with selective monoenergetic reconstructions at 80 keV significantly improves subjective image quality while objective image quality shows no significant difference compared to standard linear blending. KEY POINTS Late enhancement dual-energy CT allows for detection of chronic myocardial infarction. Monoenergetic reconstructions at 80 keV significantly improve subjective image quality. 80 keV and standard linear blending reconstructions show no significant differences. Extent of CMI detected with LIE-DECT is overestimated compared with MRI.
-
4.
Detection of hepatocellular carcinoma and liver metastases with BR14: a multicenter phase IIA study.
Hohmann, J, Müller, A, Skrok, J, Wolf, KJ, Martegani, A, Dietrich, CF, Albrecht, T
Ultrasound in medicine & biology. 2012;(3):377-82
Abstract
The study was designed primarily to find the optimal dosage range of BR14 contrast-enhanced ultrasonography (CEUS) to detect malignant focal liver lesions. Secondary objectives were the evaluation of the safety profile and comparison with contrast-enhanced MRI (CE MRI). We studied 25 patients (9 females, 16 males, mean age, 66 years) with known hepatocellular carcinoma or liver metastases at 3 centers over a 3-month period. Each patient underwent a baseline examination and at least 3 CEUS examinations with ascending dose levels (0.25 mL; 1.0 mL; 4.0 mL) of BR14. CE MRI was performed 4 weeks before or after the CEUS examination. Dedicated liver maps were used to record the location, size, and type of detected lesions. Examination quality was documented and safety parameters were assessed. The number of lesions detected by BR14 CEUS increased with dosage, whereas the number of missed lesions and the lesion sizes decreased. Despite the increasing contrast enhancement, substantial differences among dosages were not seen for other image quality parameters. No significant changes were noted in safety parameters and no serious adverse events were reported. We conclude that the recommended dose level of BR14 is between 1 mL and 4 mL; at this dosage, lesion detection is comparable to that of CE MRI.
-
5.
Predictors of statin-induced regression of left anterior descending coronary artery wall thickness as measured by high-resolution transthoracic echocardiography.
Perry, R, Joseph, MX, Chew, DP, Aylward, PE, De Pasquale, CG
Echocardiography (Mount Kisco, N.Y.). 2012;(6):641-6
Abstract
BACKGROUND Statin therapy has been shown to reduce cardiovascular risk after myocardial infarction (MI). Using a novel technique of high-resolution transthoracic echocardiography (HRTTE), we sought to assess the statin-induced changes in left anterior descending coronary artery (LAD) wall thickness in previously statin naive patients over a 12-month period. METHOD AND RESULTS Thirty subjects underwent HRTTE assessment of their LAD wall thickness predischarge post-MI (non-LAD territory) and at 3, 6, and 12 months. The LAD anterior and posterior wall thickness and vessel luminal diameter were measured. Blood lipid levels were also assessed at each study visit. All subjects were started on moderate lipid-lowering therapy (40 mg of atorvastatin or simvastatin). There was a sustained decrease in total cholesterol (-23%), triglycerides (-19%), and low-density lipoprotein (-41%) at the 3-month visit from the baseline, with no change in high-density lipoprotein level. Overall, there was no change in the LAD wall thickness and external or vessel lumen diameter over the 12-month period. Of those that demonstrated regression, the only predictor of percentage change in the LAD wall thickness was the baseline LAD wall thickness. CONCLUSION Despite a favorable change in blood lipid profile, no overall change in the LAD wall thickness was detected over a 12-month period in subjects on moderate statin therapy using HRTTE. However, using case-based analysis, regression was able to be predicted by the baseline LAD wall thickness. HRTTE may be an instructive noninvasive modality to assess response to statin intervention.
-
6.
[Automatic detection of microaneurysms in colour fundus images].
Jiménez, S, Alemany, P, Núñez Benjumea, F, Serrano, C, Acha, B, Fondón, I, Carral, F, Sánchez, C
Archivos de la Sociedad Espanola de Oftalmologia. 2011;(9):277-81
Abstract
PURPOSE We present the development of a tool for the automatic detection of microaneurysms and its clinical evaluation. The intention of this tool is to facilitate the diagnosis of diabetic retinopathy in general screening programs. METHOD The designed and developed tool consists of three stages of processing: 1) Obtaining of the basic image of eye with the retinal camera, inverted image on the green channel, and a high-pass filter of the image. This phase enhances the microaneurysms. 2) Detection of the candidates for microaneurysms, by means of an adaptive prediction filter and regions growth. 3) Selection, among the candidates, of whom microaneurysms must be considered to fulfil the criteria of circular shape, high intensity in the inverted green channel and contrasts with respect to the surrounding pixels. RESULTS We selected to 20 retinal photographs of good quality and dimensions 600x600 pixels from patients with nonproliferative diabetic retinopathy. The ophthalmologists detected 297 microaneurysms in these images. The tool for automatic detection correctly located 252 microaneurysms, with a mean sensitivity of 89% and a false positives rate of 93%. CONCLUSIONS The results obtained seem to indicate that the tool developed will be very useful for its potential use in screening programs in primary care centres. On the other hand, more work is needed on the algorithm to decrease the rate of false positives.
-
7.
Detection and characterization of focal liver lesions: a Japanese phase III, multicenter comparison between gadoxetic acid disodium-enhanced magnetic resonance imaging and contrast-enhanced computed tomography predominantly in patients with hepatocellular carcinoma and chronic liver disease.
Ichikawa, T, Saito, K, Yoshioka, N, Tanimoto, A, Gokan, T, Takehara, Y, Kamura, T, Gabata, T, Murakami, T, Ito, K, et al
Investigative radiology. 2010;(3):133-41
Abstract
OBJECTIVES To prospectively evaluate the safety and efficacy of combined unenhanced and gadoxetic acid disodium (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) imaging compared with unenhanced MR imaging and triphasic contrast-enhanced spiral computed tomography (CT) for the detection and characterization of focal liver lesions. MATERIALS AND METHODS The study was reviewed and approved by the institutional review board at each of the 15 centers involved in the study, and informed written consent was given by all patients. In total, 178 patients with suspected focal hepatic lesions (based, in most patients, on CT, tumor marker and ultrasound examinations) underwent combined MR imaging with a single, rapid injection of Gd-EOB-DTPA 0.025 mmol/kg, including T1-weighted dynamic and delayed MR images 20 to 40 minutes postinjection. Triphasic contrast-enhanced CT, the comparator examination, was performed within 4 weeks of MR imaging. Standard of references (SOR) were resection histopathology and intraoperative ultrasonography, or combined CT during arterial portography and CT hepatic arteriography; in cases where, although the major lesions were treated, some lesion(s) were not treated, follow-up superparamagnetic iron oxide-enhanced MR imaging was additionally performed. All images were assessed for differences in lesion detection and characterization (specific lesion type) by on-site readers and 3, blinded (off-site) reviewers. All adverse events (AEs) occurring within 72 hours after Gd-EOB-DTPA administration were reported. RESULTS Overall, 9.6% of patients who received Gd-EOB-DTPA reported 21 drug-related AEs. A total of 151 patients were included in the efficacy analysis. Combined MR imaging showed statistically higher sensitivity in lesion detection (67.5%-79.5%) than unenhanced MR imaging (46.5%-59.1%; P < 0.05 for all). Combined MR imaging also showed higher sensitivity in lesion detection than CT (61.1%-73.0%), with the results being statistically significant (P < 0.05) for on-site readers and 2 of 3 blinded readers. Higher sensitivity in lesion detection with combined MR imaging compared with CT was also clearly demonstrated in the following subgroups: lesions with a diameter CONCLUSION In this study, hepatocyte-specific Gd-EOB-DTPA was shown to be safe and to improve the detection and characterization of focal hepatic lesions compared with unenhanced MR imaging. When compared with spiral CT, Gd-EOB-DTPA enhanced MRI seems to be beneficial especially for the detection for smaller lesions or hepatocellular carcinoma underlying cirrhotic liver.
-
8.
Diagnostic accuracy of rim and segmental MRI enhancement of colorectal hepatic metastasis after administration of mangafodipir trisodium.
Koh, DM, Brown, G, Meer, Z, Norman, AR, Husband, JE
AJR. American journal of roentgenology. 2007;(2):W154-61
Abstract
OBJECTIVE The purpose of this study was to determine the diagnostic accuracy of rim and segmental MRI enhancement of hepatic metastasis of colorectal cancer after administration of mangafodipir trisodium (MnDPDP). SUBJECTS AND METHODS Sixty-one patients with a potentially resectable hepatic metastasis of colorectal cancer consecutively underwent breath-hold T1-weighted MRI in the axial and coronal planes 30 minutes and 24 hours after administration of MnDPDP. For each lesion, the presence or absence of rim enhancement and segmental enhancement 30 minutes and 24 hours after contrast administration was recorded. These features were evaluated separately for lesions 10 mm in diameter or larger and lesions smaller than 10 mm. The nature of each lesion was determined at histopathologic examination (n = 29) and on follow-up imaging (n = 32). RESULTS Two hundred thirty lesions were identified at MRI: 210 lesions were metastatic, and 20 were benign. Rim enhancement was observed around 22 of 210 (10%) of the metastatic lesions at 30 minutes and 199 of 210 (95%) of metastatic lesions at 24 hours. Rim enhancement at 24 hours had 94.8% (95% CI, 91.8-97.8%) sensitivity, 90.0% (68.3-98.8%) specificity, 99.0% (97.6-100%) positive predictive value, 62.1% (42.3-79.3%) negative predictive value, and 94.3% (91.4-97.3%) diagnostic accuracy for metastasis. Segmental enhancement was infrequently seen (34/210; 16%) at 24 hours but had 100% (89.7-100%) positive predictive value for metastasis. CONCLUSION Rim and segmental enhancement at MRI 24 hours after MnDPDP administration enabled accurate characterization of hepatic colorectal metastasis. These features may aid in preoperative mapping of hepatic tumor burden and disease distribution in patients with colorectal cancer.
-
9.
Intra-individual comparison of sentinel lymph node scintigraphy on the day of injection and on the following day in breast cancer.
Gutman, F, Sanson, A, Piquenot, JM, Hitzel, A, Ladonne, JM, Dessogne, P, Véra, P
Nuclear medicine communications. 2006;(1):5-9
Abstract
OBJECTIVES To compare, intra-individually, the detection rates of sentinel node on lymphoscintigraphy performed on the day of injection (D0) and on the following day (D1) in breast carcinoma. We also compared 2-day and 1-day protocols in the two groups of patients. METHODS The 2-day and 1-day protocols included 76 patients in group 1 and 23 patients in group 2. Patients from group 1 underwent lymphoscintigraphy twice--at 2 h (lymphoscintigraphy 1) and 18 h (lymphoscintigraphy 2) post-injection at four sites periareolar using 99mTc sulfur colloid. Patients from group 2 underwent lymphoscintigraphy only at 2 h post-injection. The detection rates and the number of sentinel nodes were compared in the two lymphoscintigraphy examinations for group 2. RESULTS The detection rate on lymphoscintigraphy in group 1 was 92% at D0 and 96% at D1. The overall agreement between lymphoscintigraphy 1 and lymphoscintigraphy 2 was 69/76 (91%). In 2/76 women, the sentinel node disappeared at D1 on lymphoscintigraphy, but remained detectable during surgery, and in 5/76 women, the sentinel node appeared at D1 on lymphoscintigraphy. The mean number of sentinel nodes detected on lymphoscintigraphy was 2.05+/-0.14 at D0 and 1.76+/-0.11 at D1 (P=0.004) in group 2, the detection rate of the sentinel node was 20/23 (87%). CONCLUSION Our study demonstrated that for patients undergoing the 2-day protocol for sentinel node procedure in early stage breast cancer, the optimal imaging time would be to perform lymphoscintigraphy 1 h after injection, with the possibility of imaging patients the following day in cases where lymphoscintigraphy was negative.
-
10.
Characterization of small focal liver lesions using real-time contrast-enhanced sonography: diagnostic performance analysis in 200 patients.
Xu, HX, Liu, GJ, Lu, MD, Xie, XY, Xu, ZF, Zheng, YL, Liang, JY
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2006;(3):349-61
Abstract
OBJECTIVE The purpose of this study was to assess the diagnostic performance of real-time contrast-enhanced sonography in characterization of small focal liver lesions (FLLs; < or = 3.0 cm in diameter). METHODS Two hundred small FLLs in 200 patients were examined by contrast-enhanced sonography using a contrast-specific mode of contrast pulse sequencing and a sulfur hexafluoride-filled microbubble contrast agent. The sonographic images were reviewed by 2 independent readers. A 5-point confidence level was used to discriminate malignant from benign FLLs, and specific diagnoses were recorded. The diagnostic performances were evaluated by receiver operating characteristic (ROC) analysis, and the interobserver agreement was analyzed by weighted kappa statistics. RESULTS After review of contrast-enhanced sonography, ROC analysis revealed significant improvement in differentiating between malignant and benign small FLLs that the areas under the ROC curve were 0.856 at baseline sonography versus 0.954 at contrast-enhanced sonography for reader 1 (P < .001) and 0.857 versus 0.954 for reader 2 (P = .003). The sensitivity, negative predictive value, and accuracy for both readers also improved significantly after contrast agent administration (all P < .001). A better result of specific diagnosis was obtained (38.5% [77/200] at baseline sonography versus 80.5% [161/200] at contrast-enhanced sonography for reader 1 and 34.5% [69/200] versus 80.5% [161/200] for reader 2; both P < .001) after contrast agent administration, and a better interobserver agreement was achieved (kappa = 0.425 at baseline sonography versus 0.716 at contrast-enhanced sonography). CONCLUSIONS Real-time contrast-enhanced sonography improves the diagnostic performance in small FLLs compared with baseline sonography.