-
1.
Secretin-Enhanced MRCP: How and Why-AJR Expert Panel Narrative Review.
Swensson, J, Zaheer, A, Conwell, D, Sandrasegaran, K, Manfredi, R, Tirkes, T
AJR. American journal of roentgenology. 2021;(5):1139-1149
-
-
Free full text
-
Abstract
Secretin-enhanced MRCP (S-MRCP) has advantages over standard MRCP for imaging of the pancreaticobiliary tree. Through the use of secretin to induce fluid production from the pancreas and leveraging of fluid-sensitive MRCP sequences, S-MRCP facilitates visualization of ductal anatomy, and the findings provide insight into pancreatic function, allowing radiologists to provide additional insight into a range of pancreatic conditions. This narrative review provides detailed information on the practical implementation of S-MRCP, including patient preparation, logistics of secretin administration, and dynamic secretin-enhanced MRCP acquisition. Also discussed are radiologists' interpretation and reporting of S-MRCP examinations, including assessments of dynamic compliance of the main pancreatic duct and of duodenal fluid volume. Established indications for S-MRCP include pancreas divisum, anomalous pancreaticobiliary junction, Santorinicele, Wirsungocele, chronic pancreatitis, main pancreatic duct stenosis, and assessment of complex postoperative anatomy. Equivocal or controversial indications are also described along with an approach to such indications. These indications include acute and recurrent acute pancreatitis, pancreatic exocrine function, sphincter of Oddi dysfunction, and pancreatic neoplasms.
-
2.
Clinical quantitative susceptibility mapping (QSM): Biometal imaging and its emerging roles in patient care.
Wang, Y, Spincemaille, P, Liu, Z, Dimov, A, Deh, K, Li, J, Zhang, Y, Yao, Y, Gillen, KM, Wilman, AH, et al
Journal of magnetic resonance imaging : JMRI. 2017;(4):951-971
-
-
Free full text
-
Abstract
UNLABELLED Quantitative susceptibility mapping (QSM) has enabled magnetic resonance imaging (MRI) of tissue magnetic susceptibility to advance from simple qualitative detection of hypointense blooming artifacts to precise quantitative measurement of spatial biodistributions. QSM technology may be regarded to be sufficiently developed and validated to warrant wide dissemination for clinical applications of imaging isotropic susceptibility, which is dominated by metals in tissue, including iron and calcium. These biometals are highly regulated as vital participants in normal cellular biochemistry, and their dysregulations are manifested in a variety of pathologic processes. Therefore, QSM can be used to assess important tissue functions and disease. To facilitate QSM clinical translation, this review aims to organize pertinent information for implementing a robust automated QSM technique in routine MRI practice and to summarize available knowledge on diseases for which QSM can be used to improve patient care. In brief, QSM can be generated with postprocessing whenever gradient echo MRI is performed. QSM can be useful for diseases that involve neurodegeneration, inflammation, hemorrhage, abnormal oxygen consumption, substantial alterations in highly paramagnetic cellular iron, bone mineralization, or pathologic calcification; and for all disorders in which MRI diagnosis or surveillance requires contrast agent injection. Clinicians may consider integrating QSM into their routine imaging practices by including gradient echo sequences in all relevant MRI protocols. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:951-971.
-
3.
Role of Contrast-Enhanced Ultrasound (CEUS) in Paediatric Practice: An EFSUMB Position Statement.
Sidhu, PS, Cantisani, V, Deganello, A, Dietrich, CF, Duran, C, Franke, D, Harkanyi, Z, Kosiak, W, Miele, V, Ntoulia, A, et al
Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2017;(1):33-43
Abstract
The use of contrast-enhanced ultrasound (CEUS) in adults is well established in many different areas, with a number of current applications deemed "off-label", but the use supported by clinical experience and evidence. Paediatric CEUS is also an "off-label" application until recently with approval specifically for assessment of focal liver lesions. Nevertheless there is mounting evidence of the usefulness of CEUS in children in many areas, primarily as an imaging technique that reduces exposure to radiation, iodinated contrast medium and the "patient-friendly" circumstances of ultrasonography. This position statement of the European Federation of Societies in Ultrasound and Medicine (EFSUMB) assesses the current status of CEUS applications in children and makes suggestions for further development of this technique.
-
4.
The potential of multiparametric MRI of the breast.
Pinker, K, Helbich, TH, Morris, EA
The British journal of radiology. 2017;(1069):20160715
-
-
Free full text
-
Abstract
MRI is an essential tool in breast imaging, with multiple established indications. Dynamic contrast-enhanced MRI (DCE-MRI) is the backbone of any breast MRI protocol and has an excellent sensitivity and good specificity for breast cancer diagnosis. DCE-MRI provides high-resolution morphological information, as well as some functional information about neoangiogenesis as a tumour-specific feature. To overcome limitations in specificity, several other functional MRI parameters have been investigated and the application of these combined parameters is defined as multiparametric MRI (mpMRI) of the breast. MpMRI of the breast can be performed at different field strengths (1.5-7 T) and includes both established (diffusion-weighted imaging, MR spectroscopic imaging) and novel MRI parameters (sodium imaging, chemical exchange saturation transfer imaging, blood oxygen level-dependent MRI), as well as hybrid imaging with positron emission tomography (PET)/MRI and different radiotracers. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the underlying oncogenic processes of cancer development and progression and can provide additional specificity. This article will review the current and emerging functional parameters for mpMRI of the breast for improved diagnostic accuracy in breast cancer.
-
5.
Radionuclide Imaging of Musculoskeletal Infection: A Review.
Palestro, CJ
Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2016;(9):1406-12
Abstract
There are numerous imaging tests for diagnosing musculoskeletal infection. Radiographs are routinely performed, because even when not diagnostic, they provide an anatomic overview of the region of interest that could influence subsequent procedure selection and interpretation. MRI is sensitive and provides superb anatomic detail. Bone scintigraphy accurately diagnoses osteomyelitis in bones not affected by underlying conditions. (67)Ga is used primarily for spondylodiskitis. Although in vitro labeled leukocyte imaging is the radionuclide test of choice for complicating osteomyelitis such as diabetic pedal osteomyelitis and prosthetic joint infection, it is not useful for spondylodiskitis. Antigranulocyte antibodies and antibody fragments have limitations and are not widely available. (111)In-biotin is useful for spondylodiskitis. Radiolabeled synthetic fragments of the antimicrobial peptide ubiquicidin are promising infection-specific agents. (18)F-FDG is the radiopharmaceutical of choice for spondylodiskitis. Its role in diabetic pedal osteomyelitis and prosthetic joint infection is not established. Preliminary data suggest (68)Ga may be useful in musculoskeletal infection. (124)I-fialuridine initially showed promise as an infection-specific radiopharmaceutical, but subsequent investigations were disappointing. The development of PET/CT and SPECT/CT imaging systems, which combine anatomic and functional imaging, has revolutionized diagnostic imaging. These hybrid systems are redefining the diagnostic workup of patients with suspected or known infection and inflammation by improving diagnostic accuracy and influencing patient management.
-
6.
Cardiovascular MRI with ferumoxytol.
Finn, JP, Nguyen, KL, Han, F, Zhou, Z, Salusky, I, Ayad, I, Hu, P
Clinical radiology. 2016;(8):796-806
-
-
Free full text
-
Abstract
The practice of contrast-enhanced magnetic resonance angiography (CEMRA) has changed significantly in the span of a decade. Concerns regarding gadolinium (Gd)-associated nephrogenic systemic fibrosis in those with severely impaired renal function spurred developments in low-dose CEMRA and non-contrast MRA as well as efforts to seek alternative MR contrast agents. Originally developed for MR imaging use, ferumoxytol (an ultra-small superparamagnetic iron oxide nanoparticle), is currently approved by the US Food and Drug Administration for the treatment of iron deficiency anaemia in adults with renal disease. Since its clinical availability in 2009, there has been rising interest in the scientific and clinical use of ferumoxytol as an MR contrast agent. The unique physicochemical and pharmacokinetic properties of ferumoxytol, including its long intravascular half-life and high r1 relaxivity, support a spectrum of MRI applications beyond the scope of Gd-based contrast agents. Moreover, whereas Gd is not found in biological systems, iron is essential for normal metabolism, and nutritional iron deficiency poses major public health challenges worldwide. Once the carbohydrate shell of ferumoxytol is degraded, the elemental iron at its core is incorporated into the reticuloendothelial system. These considerations position ferumoxytol as a potential game changer in the field of CEMRA and MRI. In this paper, we aim to summarise our experience with the cardiovascular applications of ferumoxytol and provide a brief synopsis of ongoing investigations on ferumoxytol-enhanced MR applications.
-
7.
Lung artefacts and their use.
Dietrich, CF, Mathis, G, Blaivas, M, Volpicelli, G, Seibel, A, Atkinson, NS, Cui, XW, Mei, F, Schreiber-Dietrich, D, Yi, D
Medical ultrasonography. 2016;(4):488-499
Abstract
The science of lung ultrasound has grown tremendously over the last two decades and lung ultrasound has not only entered the mainstream of point of care ultrasound but has become a dominant topic. Understanding lung ultrasound signs and artifacts is critical to being able to correlate findings with actual pathology and normal anatomy and physiology. Investigators have described multiple lung ultrasound artifacts and findings and it is important to understand both the physics and anatomic basis behind them. Additionally, ultrasound machine use and transducer selection can significantly affect results obtained on patient during an examination and the provider must carefully choose the correct settings. This manuscript describes the state of the art in ultrasound artifact recognition and correlation as well as management of ultrasound technology to optimize diagnostic success.
-
8.
Functional imaging of the lungs with gas agents.
Kruger, SJ, Nagle, SK, Couch, MJ, Ohno, Y, Albert, M, Fain, SB
Journal of magnetic resonance imaging : JMRI. 2016;(2):295-315
-
-
Free full text
-
Abstract
This review focuses on the state-of-the-art of the three major classes of gas contrast agents used in magnetic resonance imaging (MRI)-hyperpolarized (HP) gas, molecular oxygen, and fluorinated gas--and their application to clinical pulmonary research. During the past several years there has been accelerated development of pulmonary MRI. This has been driven in part by concerns regarding ionizing radiation using multidetector computed tomography (CT). However, MRI also offers capabilities for fast multispectral and functional imaging using gas agents that are not technically feasible with CT. Recent improvements in gradient performance and radial acquisition methods using ultrashort echo time (UTE) have contributed to advances in these functional pulmonary MRI techniques. The relative strengths and weaknesses of the main functional imaging methods and gas agents are compared and applications to measures of ventilation, diffusion, and gas exchange are presented. Functional lung MRI methods using these gas agents are improving our understanding of a wide range of chronic lung diseases, including chronic obstructive pulmonary disease, asthma, and cystic fibrosis in both adults and children.
-
9.
Update on wide- and ultra-widefield retinal imaging.
Shoughy, SS, Arevalo, JF, Kozak, I
Indian journal of ophthalmology. 2015;(7):575-81
-
-
Free full text
-
Abstract
The peripheral retina is the site of pathology in many ocular diseases and ultra-widefield (UWF) imaging is one of the new technologies available to ophthalmologists to manage some of these diseases. Currently, there are several imaging systems used in practice for the purpose of diagnostic, monitoring disease progression or response to therapy, and telemedicine. These include modalities for both adults and pediatric patients. The current systems are capable of producing wide- and UWF color fundus photographs, fluorescein and indocyanine green angiograms, and autofluorescence images. Using this technology, important clinical observations have been made in diseases such as diabetic retinopathy, uveitides, retinal vascular occlusions and tumors, intraocular tumors, retinopathy of prematurity, and age-related macular degeneration. Widefield imaging offers excellent postoperative documentation of retinal detachment surgery. New applications will soon be available to integrate this technology into large volume routine clinical practice.
-
10.
A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.
Kim, J, Wu, Y, Guo, Y, Zheng, H, Sun, PZ
Contrast media & molecular imaging. 2015;(3):163-178
Abstract
Chemical exchange saturation transfer (CEST) MRI is a versatile imaging method that probes the chemical exchange between bulk water and exchangeable protons. CEST imaging indirectly detects dilute labile protons via bulk water signal changes following selective saturation of exchangeable protons, which offers substantial sensitivity enhancement and has sparked numerous biomedical applications. Over the past decade, CEST imaging techniques have rapidly evolved owing to contributions from multiple domains, including the development of CEST mathematical models, innovative contrast agent designs, sensitive data acquisition schemes, efficient field inhomogeneity correction algorithms, and quantitative CEST (qCEST) analysis. The CEST system that underlies the apparent CEST-weighted effect, however, is complex. The experimentally measurable CEST effect depends not only on parameters such as CEST agent concentration, pH and temperature, but also on relaxation rate, magnetic field strength and more importantly, experimental parameters including repetition time, RF irradiation amplitude and scheme, and image readout. Thorough understanding of the underlying CEST system using qCEST analysis may augment the diagnostic capability of conventional imaging. In this review, we provide a concise explanation of CEST acquisition methods and processing algorithms, including their advantages and limitations, for optimization and quantification of CEST MRI experiments.