0
selected
-
1.
The meta-analysis of the effect of 68Ga-PSMA-PET/CT diagnosis of prostatic cancer compared with bone scan.
Zhao, R, Li, Y, Nie, L, Qin, K, Zhang, H, Shi, H
Medicine. 2021;(15):e25417
-
-
Free full text
-
Abstract
BACKGROUND 68Ga-PSMA-PET/CT (positron emission tomography/computed tomography) is a promising method for prostate cancer (PC) detection. However, the ability of 68Ga-PSMA-PET/CT to detect malignant bone lesions, and whether this method is superior to the existing bone imaging methods are still lack of systematic analysis. PURPOSE To evaluate the value of 68Ga-PSMA-PET/CT and bone scan in clinical diagnosis of prostatic cancer from the perspective of evidence-based medicine. METHODS PubMed, The Cochrane Library, EMBASE, Springer Link, Sinomed, CNKI, Wanfang database, and CQVIP database were searched to find the satisfactory studies that needed systematic review of trials and compared the value of 68Ga-PSMA-PET/CT and bone scan. All studies published from inception to March 31, 2020. According to the inclusion and exclusion criteria, 2 reviewers independently evaluated and extracted the literature. Review Manager 5.3 was applied to evaluate the included literature quality. The heterogeneity of the included literature was tested by Meta Disc 1.4, and the effect model was selected according to the heterogeneity test results, and the sensitivity (SEN), specificity (SPE), PLR, NLR and diagnostic odds ratio (DOR) were analyzed. After testing the heterogeneity results of literature by using the 95% confidence interval and the forest map. RESULTS A total of 4 studies were eligible for inclusion in the meta-analysis, which included 318 patients, 120 cases with bone metastasis and 198 cases without bone metastasis. The results of summary evaluation for 68Ga-PSMA-PET/CT and bone scan in diagnosis of prostatic cancer as follow respectively: The SEN were 0.97 and 0.86; the SPE were 1.00 and 0.87; the DOR were 1468.33 and 36.23; PLR were 88.45 and 6.67; NLR were 0.05 and 0.19; and the area under curve (AUC) and 95% CI were 0.9973 (1.0000-0.9927) and 0.8838 (0.9584-0.8092). CONCLUSION By comparing the diagnostic results of 68Ga-PSMA-PET/CT and bone scan imaging diagnosis methods, the 68Ga-PSMA-PET/CT has a higher SEN and SPE than bone scan, and it has a higher diagnostic efficiency for prostate cancer bone metastasis, which is worthy of clinical application.
-
2.
The Effect of Radioactive Iodine Therapy on Ovarian Function and Fertility in Female Thyroid Cancer Patients: A Systematic Review and Meta-Analysis.
Piek, MW, Postma, EL, van Leeuwaarde, R, de Boer, JP, Bos, AME, Lok, C, Stokkel, M, Filipe, MD, van der Ploeg, IMC
Thyroid : official journal of the American Thyroid Association. 2021;(4):658-668
Abstract
Introduction: Thyroid cancer is one of the most common carcinomas diagnosed in adolescents and young adults, with a rapidly rising incidence for the past three decades. Surgery is the standard treatment for patients with differentiated thyroid carcinoma (DTC), and when indicated, followed by radioactive iodine (RAI) treatment. The aim of this study was to evaluate the possible effects of RAI therapy on ovarian function and fertility in women. Methods: The PubMed, Embase, and Web of Science databases were systematically searched up to January 2020. In addition, a meta-analyses were performed for anti-Mullerian hormone (AMH) levels after RAI, comparison of AMH levels prior and 1 year after RAI, and pregnancy rates in patient with thyroid cancer receiving RAI compared with patients with thyroid cancer who did not receive RAI. Results: A total of 36 studies were eligible for full-text screening and 22 studies were included. The majority of the studies had a retrospective design. Menstrual irregularities were present in the first year after RAI in 12% and up to 31% of the patients. Approximately 8-16% of the patients experienced amenorrhea in the first year after RAI. Women who received RAI treatment (median dose 3700 MBq [range 1110-40,700 MBq]); had menopause at a slightly younger age compared with women who did not receive RAI treatment, 49.5 and 51 years, respectively (p < 0.001). Pooled AMH of the seven studies reporting AMH concentrations after RAI was 1.79 ng/mL. Of these, four studies reported AMH concentrations prior and 1 year after RAI. The mean difference was 1.50 ng/mL, which was significant. Finally, meta-analysis showed that patients undergoing RAI were not at a decreased risk of becoming pregnant. Conclusions: Most of the studies indicate that RAI therapy for DTC is not associated with a long-term decrease in pregnancy rates although meta-analyses show a significant decrease in AMH levels after RAI therapy. Prospective studies are needed to confirm these results. We recommend counseling patients about the possible effects of 131I and incorporate today's knowledge in multidisciplinary counseling.
-
3.
Longer-term recurrence rate after low versus high dose radioiodine ablation for differentiated thyroid Cancer in low and intermediate risk patients: a meta-analysis.
Vardarli, I, Weidemann, F, Aboukoura, M, Herrmann, K, Binse, I, Görges, R
BMC cancer. 2020;(1):550
Abstract
BACKGROUND Regarding the longer-term recurrence rate the optimal activity for the remnant thyroid ablation in patients with differentiated thyroid cancer (DTC) is discussed controversially. For the short-term ablation success rate up to 12 months there are already several meta-analyses. In this study we performed the first meta-analysis regarding the longer-term recurrence rate after radioactive 131-I administration. METHODS We conducted an electronic search using PubMed/MEDLINE, EMBASE and the Cochrane Library. All randomized controlled trials (RCTs) assessed the recurrence rate after radioactive iodine ablation in patients with DTC, with a follow-up of at least two years were selected. Statistics were performed by using Review Manager version 5.3 and Stata software. RESULTS Four RCTs were included in the study, involving 1501 patients. There was no indication for heterogeneity (I2 = 0%) and publication bias. The recurrence rate among patients who had a low dose 131-iodine ablation was not higher than for a high dose activity (odds ratio (OR) 0.93 [95% confidence interval (CI) 0.53-1.63]; P = 0.79). The mean follow-up time was between 4.25 and 10 years. The subgroup analysis regarding the TSH stimulated thyroglobulin values (< 10 ng/mL versus < 2 ng/mL versus ≤1 ng/mL) showed no influence on recurrence rate. CONCLUSIONS For the first time we showed that the longer-term, at least 2-year follow-up, recurrence rate among patients who had 131-iodine ablation with 1.1 GBq was not higher than with 3.7 GBq.
-
4.
Diagnostic Performance and Prognostic Value of PET/CT with Different Tracers for Brain Tumors: A Systematic Review of Published Meta-Analyses.
Treglia, G, Muoio, B, Trevisi, G, Mattoli, MV, Albano, D, Bertagna, F, Giovanella, L
International journal of molecular sciences. 2019;(19)
Abstract
BACKGROUND Several meta-analyses reporting data on the diagnostic performance or prognostic value of positron emission tomography (PET) with different tracers in detecting brain tumors have been published so far. This review article was written to summarize the evidence-based data in these settings. METHODS We have performed a comprehensive literature search of meta-analyses published in the Cochrane library and PubMed/Medline databases (from inception through July 2019) about the diagnostic performance or prognostic value of PET with different tracers in patients with brain tumors. RESULTS We have summarized the results of 24 retrieved meta-analyses on the use of PET or PET/computed tomography (CT) with different tracers in brain tumors. The tracers included were: fluorine-18 fluorodeoxyglucose (18F-FDG), carbon-11 methionine (11C-methionine), fluorine-18 fluoroethyltyrosine (18F-FET), fluorine-18 dihydroxyphenylalanine (18F-FDOPA), fluorine-18 fluorothymidine (18F-FLT), and carbon-11 choline (11C-choline). Evidence-based data demonstrated good diagnostic performance of PET with different tracers in detecting brain tumors, in particular, radiolabelled amino acid tracers showed the highest diagnostic performance values. All the PET tracers evaluated had significant prognostic value in patients with glioma. CONCLUSIONS Evidence-based data showed a good diagnostic performance for some PET tracers in specific indications and significant prognostic value in brain tumors.