1.
Randomized Comparison of the Polymer-Free Biolimus-Coated BioFreedom Stent With the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Orsiro Stent in an All-Comers Population Treated With Percutaneous Coronary Intervention: The SORT OUT IX Trial.
Jensen, Lisette Okkels, Maeng, M, Raungaard, B, Kahlert, J, Ellert, J, Jakobsen, L, Villadsen, AB, Veien, KT, Kristensen, SD, Ahlehoff, O, et al
Circulation. 2020;(25):2052-2063
Abstract
BACKGROUND In patients with increased bleeding risk, the biolimus A9-coated BioFreedom stent, a stainless steel drug-coated stent free from polymer, has shown superiority compared with a bare-metal stent. The aim of this study was to investigate whether the BioFreedom stent is noninferior to a modern ultrathin strut biodegradable polymer cobalt-chromium sirolimus-eluting Orsiro stent in an all-comers patient population treated with percutaneous coronary intervention. METHODS The SORT OUT IX trial (Scandinavian Organization for Randomized Trials With Clinical Outcome IX), was a large-scale, registry-based, randomized, multicenter, single-blind, 2-arm, noninferiority trial. The primary end point, major adverse cardiovascular events, was defined as the composite of cardiac death, myocardial infarction not related to any segment other than the target lesion, or target lesion revascularization within 1 year, analyzed by intention-to-treat. The trial was powered to assess noninferiority for major adverse cardiovascular events of the BioFreedom stent compared with the Orsiro stent with a predetermined noninferiority margin of 0.021. RESULTS Between December 14, 2015 and April 21, 2017, 3151 patients were assigned to treatment with the BioFreedom stent (1572 patients, 1966 lesions) or to the Orsiro stent (1579 patients, 1985 lesions). Five patients were lost to follow-up because of emigration (99.9% follow-up rate). Mean age was 66.3±10.9, diabetes mellitus was seen in 19.3% of patients, and 53% of the patients had acute coronary syndromes. At 1 year, intention-to-treat analysis showed that 79 (5.0%) patients, who were assigned the BioFreedom stent, and 59 (3.7%), who were assigned the Orsiro stent, met the primary end point (absolute risk difference 1.29% [upper limit of one-sided 95% CI 2.50%]; Pnoninferiority=0.14). Significantly more patients in the BioFreedom stent group had target lesion revascularization than those in the Orsiro stent group (55 [3.5%] vs 20 [1.3%], rate ratio 2.77 [95% CI, 1.66-4.62]; P<0.0001). CONCLUSIONS The biolimus A9-coated BioFreedom polymer-free stent did not meet criteria for noninferiority for major adverse cardiovascular events at 12 months when compared with the ultrathin strut biodegradable polymer sirolimus-eluting Orsiro stent in an all-comers population Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02623140.
-
2.
Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (BIOSTEMI): a single-blind, prospective, randomised superiority trial.
Iglesias, JF, Muller, O, Heg, D, Roffi, M, Kurz, DJ, Moarof, I, Weilenmann, D, Kaiser, C, Tapponnier, M, Stortecky, S, et al
Lancet (London, England). 2019;(10205):1243-1253
Abstract
BACKGROUND Newer-generation drug-eluting stents that combine ultrathin strut metallic platforms with biodegradable polymers might facilitate vascular healing and improve clinical outcomes in patients with acute myocardial infarction undergoing primary percutaneous coronary intervention (PCI) compared with contemporary thin strut second-generation drug-eluting stents. We did a randomised clinical trial to investigate the safety and efficacy of ultrathin strut biodegradable polymer sirolimus-eluting stents versus thin strut durable polymer everolimus-eluting stents in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary PCI. METHODS The BIOSTEMI trial was an investigator-initiated, multicentre, prospective, single-blind, randomised superiority trial at ten hospitals in Switzerland. Patients aged 18 years or older with acute STEMI who were referred for primary PCI were eligible to participate. Patients were randomly allocated (1:1) to either biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Central randomisation was done based on a computer-generated allocation sequence with variable block sizes of 2, 4, and 6, which was stratified by centre, diabetes status, and presence or absence of multivessel coronary artery disease, and concealed using a secure web-based system. Patients and treating physicians were aware of group allocations, whereas outcome assessors were masked to the allocated stent. The experimental stent (Orsiro; Biotronik; Bülach, Switzerland) consisted of an ultrathin strut cobalt-chromium metallic stent platform releasing sirolimus from a biodegradable polymer. The control stent (Xience Xpedition/Alpine; Abbott Vascular, Abbott Park, IL, USA) consisted of a thin strut cobalt-chromium stent platform that releases everolimus from a durable polymer. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial reinfarction (Q-wave and non-Q-wave), and clinically-indicated target lesion revascularisation, within 12 months of the index procedure. All analyses were done with the individual participant as the unit of analysis and according to the intention-to-treat principle. The trial was registered with ClinicalTrials.gov, number NCT02579031. FINDINGS Between April 26, 2016, and March 9, 2018, we randomly assigned 1300 patients (1623 lesions) with acute myocardial infarction to treatment with biodegradable polymer sirolimus-eluting stents (649 patients and 816 lesions) or durable polymer everolimus-eluting stents (651 patients and 806 lesions). At 12 months, follow-up data were available for 614 (95%) patients treated with biodegradable polymer sirolimus-eluting stents and 626 (96%) patients treated with durable polymer everolimus-eluting stents. The primary composite endpoint of target lesion failure occurred in 25 (4%) of 649 patients treated with biodegradable polymer sirolimus-eluting stents and 36 (6%) of 651 patients treated with durable polymer everolimus-eluting stents (difference -1·6 percentage points; rate ratio 0·59, 95% Bayesian credibility interval 0·37-0·94; posterior probability of superiority 0·986). Cardiac death, target vessel myocardial reinfarction, clinically-indicated target lesion revascularisation, and definite stent thrombosis were similar between the two treatment groups in the 12 months of follow-up. INTERPRETATION In patients with acute STEMI undergoing primary PCI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 1 year. This difference was driven by reduced ischaemia-driven target lesion revascularisation in patients treated with biodegradable polymer sirolimus-eluting stents compared with durable polymer everolimus-eluting stents. FUNDING Biotronik.
-
3.
Twelve-month angiographic and clinical outcomes of the XINSORB bioresorbable sirolimus-eluting scaffold and a metallic stent in patients with coronary artery disease.
Wu, Y, Shen, L, Yin, J, Chen, J, Qian, J, Ge, L, Ge, J, ,
International journal of cardiology. 2019;:61-66
Abstract
BACKGROUND Recent studies showed bioresorbable scaffold (BRS) increased risks of late target lesion failure (TLF) and thrombosis. XINSORB scaffold is a poly-L-lactic acid based BRS. METHODS The study included randomization and registry parts. Eligible patients with one or two de novo lesions were randomly 1:1 assigned to XINSORB scaffold and sirolimus-eluting stent (SES) in randomization part. These patients were clinically and angiographically assessed. In registry part, patients were treated with XINSORB scaffold only and were clinically assessed. The primary endpoint was in-segment late luminal loss (LLL) at 12-month in randomization part. The secondary endpoint was 12-month TLF in all XINSORB-treated patients. RESULTS Total 395 and 798 patients were enrolled in randomization and registry part, respectively. Device success was 98.0% (1069/1091) in all XINSORB-treated and 100% (221/221) in SES-treated lesions. The primary endpoint of in-segment LLL at 12-month was 0.19 ± 0.32 mm in XINSORB and 0.31 ± 0.41 mm in SES (P = 0.003), which met the noninferior margin of 0.195 mm (95% CI: -0.20, -0.04, P ≪ 0.0001). No difference was found in TLF between two devices. In all XINSORB-treated patients, 12-month TLF was 0.8% (8/998), which also met the noninferior margin of 9.0% (95% CI: 0.3%, 1.4%, P ≪ 0.0001). Only one device thrombosis was recorded in all XINSORB-treated patients while none in SES. CONCLUSIONS In the multicenter clinical trial, XINSORB BRS was noninferior to sirolimus-eluting stent for the primary endpoint of in-segment LLL at 12-month in patients with simple and moderate complex de novo coronary lesions. TLF at 12-month was low and comparable.
-
4.
Insulin-mimetic effects of short-term rapamycin in type 1 diabetic patients prior to islet transplantation.
Benedini, S, Ermetici, F, Briganti, S, Codella, R, Terruzzi, I, Maffi, P, Caldara, R, Secchi, A, Nano, R, Piemonti, L, et al
Acta diabetologica. 2018;(7):715-722
Abstract
BACKGROUND The immunosuppressive drug rapamycin may influence insulin sensitivity in insulin-responsive tissues. AIMS This study aimed at evaluating the effectiveness of rapamycin pre-treatment before pancreatic islet allotransplantation (ITx) in patients with type 1 diabetes mellitus (T1DM). METHODS Forty-one T1DM patients were studied. Thirteen patients with poor glycemic control underwent a short-term rapamycin treatment before ITx (Group 1), and they were compared to 28 patients undergoing ITx without rapamycin pre-treatment (Group 2). Outcomes were daily insulin requirement (DIR), fasting blood glucose, HbA1c, C-peptide and the SUITO index of beta-cell function. A subgroup of patients pre-treated with rapamycin before ITx underwent euglycemic hyperinsulinemic clamp with [6,6-2H2] glucose before and after ITx to evaluate insulin sensitivity. RESULTS We found a significant reduction in DIR after rapamycin pre-treatment (- 8 ± 6 U/day, mean ± SD, p < 0.001) and 1 year after ITx. DIR reduction 1 year after ITx was greater in Group 1 as compared to Group 2 (- 37 ± 15 vs. - 19 ± 13 U/day, p = 0.005) and remained significant after adjusting for gender, age, glucose and baseline HbA1c (beta = 18.2 ± 5.9, p = 0.006). Fasting glucose and HbA1c significantly decreased 1 year after ITx in Group 1 (HbA1c: - 2.1 ± 1.4%, p = 0.002), while fasting C-peptide (+0.5 ± 0.3 nmol/l, p = 0.002) and SUITO index increased (+57.4 ± 39.7, p = 0.016), without differences between the two groups. Hepatic glucose production decreased after rapamycin pre-treatment (- 1.1 ± 1.1 mg/kg/min, p = 0.04) and after ITx (- 1.6 ± 0.6 mg/kg/min, p = 0.015), while no changes in peripheral glucose disposal were observed. CONCLUSIONS Rapamycin pre-treatment before ITx succeeds in reducing insulin requirement, enhancing hepatic insulin sensitivity. This treatment may improve short-term ITx outcomes, possibly in selected patients with T1DM complicated by insulin resistance. CLINICAL TRIAL Clinicaltrials.gov NCT01060605; NCT00014911.
-
5.
Ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents versus thin-strut, durable-polymer, everolimus-eluting stents for percutaneous coronary revascularisation: 5-year outcomes of the BIOSCIENCE randomised trial.
Pilgrim, T, Piccolo, R, Heg, D, Roffi, M, Tüller, D, Muller, O, Moarof, I, Siontis, GCM, Cook, S, Weilenmann, D, et al
Lancet (London, England). 2018;(10149):737-746
Abstract
BACKGROUND Drug-eluting stents combining an ultrathin cobalt-chromium stent platform with a biodegradable polymer eluting sirolimus have been shown to be non-inferior or superior to thin-strut, durable-polymer, everolimus-eluting stents in terms of 1 year safety and efficacy outcomes. METHODS In the randomised, single-blind, multicentre, non-inferiority BIOSCIENCE trial, we compared biodegradable-polymer sirolimus-eluting stents with durable-polymer everolimus-eluting stents in patients with chronic stable coronary artery disease or acute coronary syndromes. Here, we assess the final 5-year clinical outcomes of BIOSCIENCE with regards to the primary clinical outcome of target lesion failure, which was a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation. The primary analysis was done by intention to treat. The BIOSCIENCE trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS 2008 (95%) of 2119 patients recruited between March 1, 2012, and May 31, 2013, completed 5 years of follow-up. Target lesion failure occurred in 198 patients (cumulative incidence 20·2%) treated with biodegradable-polymer sirolimus-eluting stents and in 189 patients (18·8%) treated with durable-polymer everolimus-eluting stents (rate ratio [RR] 1·07, 95% CI 0·88-1·31; p=0·487). All-cause mortality was significantly higher in patients treated with biodegradable-polymer sirolimus-eluting stents than in those treated with durable-polymer everolimus-eluting stents (14·1% vs 10·3%; RR 1·36, 95% CI 1·06-1·75; p=0·017), driven by a difference in non-cardiovascular deaths. We observed no difference between groups in cumulative incidence of definite stent thrombosis at 5 years (1·6% in both groups; 1·02, 0·51-2·05; p=0·950). INTERPRETATION 5-year risk of target lesion failure among all-comer patients undergoing percutaneous coronary intervention is similar after implantation of ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents or thin-strut, durable-polymer, everolimus-eluting stents. Higher incidences of all-cause and non-cardiovascular mortality in patients treated with biodegradable-polymer stents eluting sirolimus than in those treated with durable-polymer stents eluting everolimus warrant careful observation in ongoing clinical trials. FUNDING Clinical Trials Unit of the University of Bern and Biotronik.
-
6.
One-year outcomes of a BioMime™ Sirolimus-Eluting Coronary Stent System with a biodegradable polymer in all-comers coronary artery disease patients: The meriT-3 study.
Jain, RK, Chakravarthi, P, Shetty, R, Ramchandra, P, Polavarapu, RS, Wander, GS, Mohan, B, Banker, DN, Dharmadhikari, A, Bansal, SS, et al
Indian heart journal. 2016;(5):599-603
Abstract
OBJECTIVES The aim of the merit-3 study was to determine the safety and performance of the BioMime Sirolimus-Eluting Coronary Stent System (SES) in all-comer patients with coronary artery disease (CAD) in one-year clinical follow-up period. METHODS The meriT-3 was a multi-centre, observational, post-marketing study conducted in 1161 patients with CAD who were implanted with BioMime SES at 15 sites in India. The primary endpoint was major adverse cardiac event (MACE) at one year defined as the composite of cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR). Clinical follow-up was performed at 1, 6, and 12 months. Major adverse cardiac event occurred at 30 days and subsequently at 6 months and at long-term follow-up of 1 year was analyzed. RESULTS MACE observed at 1 and 6 months follow-up was 16 (1.38%) and 21 (1.83%) respectively. Cumulative 1 year MACE was 26 (2.35%) with 16 (1.39%) all cause death, 4 (0.35%) MI and 6 (0.52%) TLR. In addition, ST was observed in 1 (0.09%) patient. CONCLUSIONS The present study suggests that the BioMime SES is safe and effective in a "real-world", all-comers CAD patients, indicating low rates of MACE. CTRI ACKNOWLEDGEMENT NO REF/2016/07/011808.
-
7.
Sirolimus-eluting stent is superior to paclitaxel-eluting stent for coronary intervention in patients with renal insufficiency: Long-term clinical outcomes.
Ann, SH, Seo, SM, Kim, PJ, Koh, YS, Her, SH, Shin, DI, Park, HJ, Park, CS, Lee, JM, Kim, DB, et al
Cardiology journal. 2016;(6):637-646
Abstract
BACKGROUND Renal insufficiency (RI) is an independent risk factor for the adverse cardiovascular events. Long-term clinical outcome of percutaneous coronary intervention (PCI) in patients with RI is unknown especially in the era of first generation drug-eluting stents (DES). This study aims at comparing clinical outcomes between sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) based on large scaled registry. METHODS Patients who underwent PCI with DES from January 2004 to December 2009 in the Catholic University of Korea-PCI (COACT) registry were prospectively enrolled. A group of 1,033 patients with RI, defined as estimated glomerular filtration rate under 60 mL/min, were analyzed. Major adverse cardiac events (MACE), including all-cause death, non-fatal myocardial infarction (MI), target lesion revascularization (TLR), and target vessel revascularization (TVR) according to the type of stents were compared. RESULTS Median follow-up period was 810 days (interquartile range: from 361 to 1,354 days). A group of 612 (59.2%) patients were treated with SES and 421 (40.8%) patients were treated with PES. The PES vs. SES group had significantly higher rate of MACE (35.9% vs. 28.3%, p = 0.01). In multivariate Cox hazard regression analysis, PES vs. SES group had significantly higher rate of MACE (adjusted hazard ratio [AHR] 1.29, 95% confidence interval [CI] 1.02-1.64, p = 0.033), particularly pronounced by all-cause death (AHR 1.34, 95% CI 1.008-1.770; p = 0.044). In further analysis with propensity score matching, overall findings were consistent. CONCLUSIONS In patients with RI, PCI using PES provides poorer clinical outcomes than SES in terms of MACE and all-cause death.
-
8.
Comparison of the Absorbable Polymer Sirolimus-Eluting Stent (MiStent) to the Durable Polymer Everolimus-Eluting Stent (Xience) (from the DESSOLVE I/II and ISAR-TEST-4 Studies).
Lansky, AJ, Kastrati, A, Edelman, ER, Parise, H, Ng, VG, Ormiston, J, Wijns, W, Byrne, RA
The American journal of cardiology. 2016;(4):532-538
-
-
Free full text
-
Abstract
We compared the outcomes of a novel, thin-strut, cobalt-chromium, absorbable, polymer sirolimus-eluting stent (APSES; MiStent) to the durable polymer cobalt-chromium everolimus-eluting stent (EES; Xience). A propensity-matched analysis was performed comparing data from the DES With Sirolimus and a Bioabsorbable Polymer for the Treatment of Patients With De Novo Lesions in the Native Coronary Arteries (DESSOLVE) I and II studies, evaluating the APSES to the EES arm of the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents-4 study. Target lesion failure (TLF) and its components were evaluated at 12 months and annually to 3 years; 805 patients (APSES = 153; EES = 652) were included with propensity matching in 204 patients (APSES = 102; EES = 102). APSES compared with EES had lower TLF at 1 year (3.0% vs 8.0%, p = 0.12) driven by a difference in target lesion revascularization (TLR; 1% vs 6%, p = 0.05), with no difference in target vessel myocardial infarction (p = 0.56) or stent thrombosis (p = 0.31). At 3 years, TLF (5.0% vs 12.5%, p = 0.07) and TLR (2.0% vs 8.4%, p = 0.04) remained lower with APSES. By landmark analysis, there was no significant difference in TLF between 1 and 3 years (p = 0.36). In conclusion, in a propensity-matched analysis, the APSES demonstrated reduced clinically indicated TLR rates at 1 and 3 years compared with the durable polymer EES, with minimal accrual of events between 1 and 3 years.
-
9.
Comparison of sirolimus eluting stent with bioresorbable polymer to everolimus eluting stent with permanent polymer in bifurcation lesions: Results from CENTURY II trial.
Orvin, K, Carrie, D, Richardt, G, Desmet, W, Assali, A, Werner, G, Ikari, Y, Fujii, K, Goicolea, J, Dangoisse, V, et al
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2016;(6):1092-100
Abstract
OBJECTIVE To demonstrate the safety and efficacy of a new sirolimus eluting stent with bioresorbable polymer, Ultimaster, (BP-SES) compared with everolimus-eluting, permanent polymer, Xience stent (PP-EES) in bifurcation lesions with respect to the freedom from Target Lesion Failure at 1-year. METHODS Within 1,119 patients enrolled in the CENTURY II randomized controlled multicenter trial, 194 patients were treated for bifurcation lesions and randomized to either BP-SES (n = 95) or PP-EES (n = 99). The primary endpoint was freedom from target lesion failure (TLF) composite endpoint [cardiac death, MI not clearly attributable to a non-target vessel, and clinically driven target lesion revascularization (TLR)] at 1-year. RESULTS Baseline patient demographic, angiographic, and stenting characteristics were similar in both study arms. A single stent technique with provisional or "cross over" stenting were the most widely used in both arms (93.2% BP-SES vs. 92.4% PP-EES). Freedom from TLF at 1-year was 94.7% for BP-SES and 91.9% for PP-EES (P for noninferiority 0.031). The rate of clinically driven target lesion revascularization (TLR) at 1-year was 3.2% for BP-SES and 3.0% for PP-EES (P = 0.95). There were no significant differences detected in any of the individual clinical endpoints or other secondary clinical endpoints between the study arms at 1-year follow up. CONCLUSIONS The new bioresorbable polymer sirolimus-eluting stent showed safety and efficacy profiles similar to durable polymer everolimus-eluting in the treatment of patients with bifurcation lesions at 1-year follow up. © 2015 Wiley Periodicals, Inc.
-
10.
Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial.
Kuramitsu, S, Kazuno, Y, Sonoda, S, Domei, T, Jinnouchi, H, Yamaji, K, Soga, Y, Shirai, S, Ando, K, Saito, S
European heart journal. Cardiovascular Imaging. 2016;(1):34-40
-
-
Free full text
-
Abstract
AIMS: The Ultimaster bioresorbable polymer sirolimus-eluting stent (BP-SES) is a newly developed drug-eluting stent (DES) that consists of a thin-strut, cobalt chromium with bioresorbable polymer coated only albuminally. We sought to compare tissue coverage in coronary lesions treated with BP-SES with the XIENCE permanent polymer everolimus-eluting stent (PP-EES) using optical coherence tomography (OCT). METHODS AND RESULTS A total of 36 patients participated in the CENTURY II trial in our institution and were randomly assigned to BP-SES (n = 15) and PP-EES (n = 21). Of these, 27 patients (13 BP-SES and 14 PP-EES) underwent OCT at 9-month follow-up. Tissue coverage and apposition were assessed on each strut, and the results in both groups were compared using multilevel logistic or linear regression models with random effects at three levels: patient, lesion, and struts. A total of 6450 struts (BP-SES, n = 2951; PP-EES, n = 3499) were analysed. Thirty and 79 uncovered struts (1.02 and 2.26%, P = 0.35), and 3 and 4 malapposed struts (0.10 and 0.11%, P = 0.94) were found in BP-SES and PP-EES groups, respectively. Mean neointimal thickness did not significantly differ between both groups (110 ± 10 vs. 93 ± 10 µm, P = 0.22). No significant differences in per cent neointimal volume obstruction (13.2 ± 4.6 vs. 10.5 ± 4.9%, P = 0.14) or other areas-volumetric parameters were detected between both groups. CONCLUSION BP-SES shows an excellent vascular healing response at 9-month follow-up, which is similar to PP-EES.