1.
Comparison of postoperative effectiveness of less invasive short external rotator sparing approach versus standard posterior approach for total hip arthroplasty.
Wang, T, Zhou, Y, Li, X, Gao, S, Yang, Q
Journal of orthopaedic surgery and research. 2021;(1):46
Abstract
BACKGROUND Most of the studies assessing the corrective posterior total hip arthroplasty (THA) mainly focused on the mini-incision approach. Studies exploring the short external rotator sparing approach are rare. Therefore, this study aimed to compare the effectiveness of standard posterior approach and short external rotator sparing approach. METHODS This prospective observational study included 126 patients who underwent THA in June 2017-June 2018. Patients were assigned to standard (standard posterior approach) and corrective (short external rotator sparing approach) groups based on the surgical method. Surgical data were recorded postoperatively. Postoperative hip joint recovery was assessed using the times to ambulation and independent stair use, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, Harris score, and Oxford hip score (OHS) at 2 and 8 postoperative weeks. The visual analog scale (VAS) was used for postoperative pain assessment. RESULTS Postoperative changes of creatine kinase (CK), myoglobin, CRP, and prosthesis position were similar in both groups (P > 0.05). However, intraoperative blood loss (P < 0.001) and postoperative 6-h drainage volume (P = 0.03), hospital stay, blood transfusion rate, and times to ambulation and independent stair use were significantly reduced in the corrective group. Postoperatively, Oxford, and WOMAC scores significantly decreased in both groups. After surgery, the VAS score was more overtly decreased in the corrective group compared with the standard group. CONCLUSIONS This study concluded that the less invasive short external rotator sparing approach for THA caused less damage, reducing perioperative blood loss, shortening functional recovery time, maintaining prosthesis stability, and improving postoperative pain.
-
2.
Effect of 0.9% NaCl compared to plasma-lyte on biomarkers of kidney injury, sodium excretion and tubular transport proteins in patients undergoing primary uncemented hip replacement - a randomized trial.
Østergaard, AM, Jørgensen, AN, Bøvling, S, Ekeløf, NP, Mose, FH, Bech, JN
BMC nephrology. 2021;(1):111
Abstract
BACKGROUND Isotonic saline (IS) is widely used to secure perioperative cardiovascular stability. However, the high amount of chloride in IS can induce hyperchloremic acidosis. Therefore, IS is suspected to increase the risk of acute kidney injury (AKI). Biomarkers may have potential as indicators. METHODS In a double-blinded, placebo-controlled study, 38 patients undergoing primary uncemented hip replacement were randomized to IS or PlasmaLyte (PL). Infusion was given during surgery as 15 ml/kg the first hour and 5 ml/kg the following two hours. Urinary samples were collected upon admission and the day after surgery. As surgery was initiated, urine was collected over the course of 4 h. Hereafter, another urine collection proceeded until the morning. Urine was analyzed for markers of AKI neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule-1 (KIM-1). Arterious and venous blood samples for measurements of pH and plasma electrolytes including chloride (p-Cl) were collected as surgery was initiated, at the end of surgery and the following morning. RESULTS IS induced an increase in p-Cl (111 ± 2 mmol/L after IS and 108 ± 3 after PL, p = 0.004) and a decrease in pH (7.39 ± 0.02 after IS and 7.43 ± 0.03 after PL, p = 0.001). Urinary NGAL excretion increased in both groups (ΔNGAL: 5.5 [4.1; 11.7] μg/mmol creatinine p = 0.004 after IS vs. 5.5 [2.1;9.4] μg/mmol creatinine after PL, p < 0.001). No difference was found between the groups (p = 0.839). Similarly, urinary KIM-1 excretion increased in both groups (ΔKIM-1: IS 115.8 [74.1; 156.2] ng/mmol creatinine, p < 0.001 vs. PL 152.4 [120.1; 307.9] ng/mmol creatinine, p < 0.001). No difference between the groups (p = 0.064). FENa increased (1.08 ± 0.52% after IS and 1.66 ± 1.15% after PL, p = 0.032). ENaC excretion was different within groups (p = 0.019). CONCLUSION A significantly higher plasma chloride and a lower pH was present in the group receiving isotonic saline. However, u-NGAL and u-KIM-1 increased significantly in both groups after surgery despite absence of changes in creatinine. These results indicate that surgery induced subclinical kidney injury. Also, the IS group had a delayed sodium excretion as compared to the PL group which may indicate that IS affects renal sodium excretion differently from PL. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT02528448 , 19/08/2015.
-
3.
Equal Primary Fixation of Resurfacing Stem, but Inferior Cup Fixation With Anterolateral vs Posterior Surgical Approach. A 2-Year Blinded Randomized Radiostereometric and Dual-energy X-Ray Absorptiometry Study of Metal-on-Metal Hip Resurfacing Arthroplasty.
Hjorth, MH, Lorenzen, ND, Søballe, K, Jakobsen, SS, Stilling, M
The Journal of arthroplasty. 2017;(11):3412-3420
Abstract
BACKGROUND The anterolateral (AntLat) surgical approach may spare the blood supply to the femoral head and improve the accuracy of cup positioning in metal-on-metal hip resurfacing arthroplasty. Thereby, potentially lessen complications such as avascular head necrosis, femoral neck narrowing and fracture, improve implant fixation, and lessen periprosthetic bone mineral density (BMD) loss. METHODS Between November 2008 and January 2012, a randomized clinical trial was performed at Aarhus University Hospital. A total of 49 patients (28 males) were allocated to metal-on-metal hip resurfacing arthroplasty by the AntLat (n = 25) or the posterior (Post; n = 24) surgical approach. Patients were followed with radiostereometric analysis, measurements of periprosthetic BMD, clinical outcome scores of Harris hip score and visual analogue scale, serum metal ions, and conventional radiographs. RESULTS At 3 months, cups in the AntLat group had higher total translations of mean 1.00 ± 0.70 mm vs mean 0.64 ± 0.45 mm in the post group (P = .04), and higher total rotations of mean 2.44° ± 1.36° vs mean 1.39° ± 1.17° in the Post group (P = .002). All migrations of cup and stem were similar at 1 and 2 years postoperative (P > .07). At 1 year, periprosthetic BMD since postoperative at the medial side of the stem was reduced to mean 98.45% ± 8.57% in the AntLat group, and increased to mean 105.57% ± 11.07% in the Post group (P = .02), but measurements were comparable at 2 years (P = .05). CONCLUSION Cups inserted by the AntLat approach migrated more until 3 months postoperative. This illustrates a less good primary cup fixation with the AntLat approach; however, all cups were well-fixed after 3 months' follow-up indicating a good secondary fixation.
-
4.
Efficacy of Alendronate for the Prevention of Bone Loss in Calcar Region Following Total Hip Arthroplasty.
Yukizawa, Y, Inaba, Y, Kobayashi, N, Choe, H, Kubota, S, Saito, T
The Journal of arthroplasty. 2017;(7):2176-2180
Abstract
BACKGROUND Bone mineral density (BMD) loss around femoral implants, particularly in the proximal femur, is a common outcome after total hip arthroplasty. Previous studies reported the prevention of postsurgical decrease in BMD with the use of osteoporosis drug therapy. This randomized study evaluated the efficacy of alendronate and alfacalcidol for preserving BMD over a long-term follow-up. METHODS Sixty consecutive patients with hip osteoarthritis who had undergone primary cementless total hip arthroplasty were randomly assigned to an alendronate (n = 20), alfacalcidol (n = 18), or control (n = 22) group. Periprosthetic BMD was measured using dual-energy X-ray absorptiometry at 1 week, 1 year, and the current follow-up (minimum 9 years after surgery). Changes in BMD are reported as mean percentages relative to the values at 1 week (baseline reference). RESULTS All groups showed a significant decrease in the BMD of the calcar at the current follow-up compared to the values at both 1 week and 1 year postoperatively (P < .001). The BMD values were significantly higher in the alendronate group than in the alfacalcidol and control groups (P < .05). The BMD values at the current follow-up were 76% ± 30% (alendronate group), 64% ± 22% (alfacalcidol group), and 59% ± 22% (control group) of the baseline values. CONCLUSION Our findings demonstrate the efficacy of early administration of alendronate for the prevention of bone loss in the calcar region.
-
5.
The effect of different bearing surfaces on metal ion levels in urine following 28 mm metal-on-metal and 28 mm metal-on-polyethylene total hip arthroplasty.
Tiusanen, H, Mäkelä, K, Kiilunen, M, Sarantsin, P, Sipola, E, Pesola, M
Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society. 2013;(3):197-203
Abstract
BACKGROUND AND AIMS Recent advancements in manufacturing technology have enabled more precise tolerances and surface finishes using metal-on-metal bearing surfaces in total hip arthroplasty. The aim of this study was to compare the level of metal ions in urine after implantation of a 28-mm metal-on-metal bearing manufactured from high-carbon wrought alloy and a 28-mm metal-on-polyethylene bearing. MATERIAL AND METHODS A total of 92 total hip arthroplasty patients were prospectively randomized into two groups: those receiving metal-on-metal bearings and those receiving metal-on-polyethylene bearings. Chromium, cobalt, and molybdenum ion levels in urine were measured preoperatively and at 1 year and 2 years postoperatively. RESULTS In the metal-on-polyethylene group, there was a slight increase in mean chromium and cobalt concentrations at 2-year follow-up compared to the preoperative level (p = 0.02 for both chromium and cobalt). In the metal-on-metal group, there was a 15-fold increase in chromium and a 26-fold increase in cobalt at 2-year follow-up compared to the preoperative level (p < 0.001 for both chromium and cobalt). However, the quantity of chromium and cobalt in urine from the metal-on-metal group was not higher at 2-year follow-up than at 1-year follow-up (p = 0.5 and p = 0.6, respectively). CONCLUSIONS The 28-mm metal-on-metal bearings yield chromium and cobalt concentrations in urine that can be higher than those recommended for occupational exposure. However, our results also indicate that a steady state in wear and ion production using metal-on-metal total hip arthroplasty can occur.
-
6.
More than 50% reduction of wear in polyethylene liners with alumina heads compared to cobalt-chrome heads in hip replacements: a 10-year follow-up with radiostereometry in 43 hips.
Dahl, J, Snorrason, F, Nordsletten, L, Röhrl, SM
Acta orthopaedica. 2013;(4):360-4
Abstract
BACKGROUND AND PURPOSE Excessive wear of acetabular liners in hip replacements may lead to osteolysis and cup loosening. Different head materials are currently used. We measured differences in wear between alumina and cobalt-chrome heads with the same polyethylene liner. PATIENTS AND METHODS 39 patients (43 hips) with osteoarthritis were included in a study with 10-year follow-up. Wear was measured as proximal and 3D penetration of the head in the liner with radiostereometry (RSA). All the patients were followed clinically with Harris hip score (HHS) for up to 10 years. Radiolucent lines and osteolytic lesions were assessed on plain radiographs. RESULTS With alumina heads, proximal wear (95% CI) after 10 years was 0.62 (0.44-0.80) mm as compared to 1.40 (1.00-1.80) mm in the cobalt-chrome group. For 3D wear, the results were 0.87 (0.69-1.04) mm for alumina heads and 1.78 (1.35-2.21) mm for cobalt-chrome heads. Median (range) HHS was 98 (77-100) in the alumina group and it was 93 (50-100) in the cobalt-chrome group (p = 0.01). We found no difference in osteolysis between the groups. INTERPRETATION We found better wear properties with alumina heads than with cobalt-chrome heads. We recommend the use of alumina heads in patients in whom a high wear rate might be anticipated.
-
7.
Cushion bearings versus large diameter head metal-on-metal bearings in total hip arthroplasty: a short-term metal ion study.
Moroni, A, Nocco, E, Hoque, M, Diremigio, E, Buffoli, D, Cantù, F, Catalani, S, Apostoli, P
Archives of orthopaedic and trauma surgery. 2012;(1):123-9
Abstract
INTRODUCTION Metal-on-metal total hip arthroplasty (MOM THA) has the advantage of replicating the femoral head size, but the postoperative elevation of serum metal ion levels is a cause for concern. Metal-on-polycarbonate-urethane is a new cushion bearing featuring a large diameter metal head coupled with a polycarbonate-urethane liner. AIM: The aim of this study was to assess and compare serum cobalt (Co) and chromium (Cr) levels in a group of 15 patients treated with a cushion bearing THA system (Group A) and a group of 15 patients treated with a MOM THA system (Group B) at short-term. At a mean follow-up of 27.3 months (18-35 months), in Group A the median Cr and Co serum levels were significantly lower than in Group B, measuring 0.24 μg/L (0.1-2.1 μg/L) and 0.6 μg/L (0.29-2.3 μg/L) compared to 1.3 μg/L (0.1-9 μg/L, p < 0.001) and 2.9 μg/L (0.85-13.8 μg/L, p < 0.001) respectively. RESULTS All patients demonstrated an excellent clinical result, as shown by the Harris and Oxford hip scores. The cushion bearing THA studied in this paper showed clinical outcomes similar to the MOM THA bearing, with the advantage of no significant metal ion elevation in the serum. CONCLUSION These findings warrant the continued clinical study of compliant bearing options.
-
8.
Performance of new anticoagulants for thromboprophylaxis in patients undergoing hip and knee replacement surgery.
Mahan, CE, Kaatz, S
Pharmacotherapy. 2012;(11):1036-48
Abstract
Venous thromboembolism (VTE) represents one of the most preventable complications that occur during hospitalization, and measurement of hospital-associated VTE is becoming a key component in hospital quality measures. Guidelines for the prevention of deep vein thrombosis and pulmonary embolism have been published by several organizations to guide quality of care; however, some of the guidelines are divergent in their recommendations. This disagreement among guidelines is most pronounced in patients undergoing major orthopedic surgery. The advent of newer anticoagulants, which are now approved or in late-phase development, have already had an effect on the guidelines and may also affect quality measures in the future. In this article, we review the burden of VTE in patients undergoing major orthopedic surgery, highlight the differences in the guidelines, and examine the new anticoagulants as they are related to VTE prophylaxis in this patient group.
-
9.
The efficacy and safety of pharmacological prophylaxis of venous thromboembolism following elective knee or hip replacement: systematic review and network meta-analysis.
Cohen, A, Drost, P, Marchant, N, Mitchell, S, Orme, M, Rublee, D, Simon, TA, Sutton, A
Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis. 2012;(6):611-27
-
-
Free full text
-
Abstract
The present systematic review was conducted to assess the efficacy and safety of apixaban versus other anticoagulants, for the prevention of venous thromboembolism (VTE) following total hip replacement (THR) and total knee replacement (TKR) surgery. Electronic databases were interrogated to identify relevant randomized controlled trials. A series of direct/indirect comparisons and a network meta-analysis were conducted. Indirect comparisons found that the odds ratio of "all VTE and all-cause death" were significantly higher for dabigatran than for apixaban in patients with THR (odds ratio [OR], 2.51; 95% confidence interval [CI], 1.50-4.21) and TKR (OR, 1.72; 95% CI, 1.22-2.42). Rivaroxaban showed similar efficacy to apixaban in patients with THR and TKR (OR, 0.69; 95% CI, 0.38-1.25 and OR, 0.83; 95% CI, 0.57-1.19, respectively). No significant differences were observed in bleeding outcomes between treatments. The novel anticoagulants apixaban, rivaroxaban, and dabigatran demonstrated similar or improved efficacy and similar safety compared with current therapies in this indication.
-
10.
Component positioning in primary total hip replacement: a prospective comparative study of two anterolateral approaches, minimally invasive versus gluteus medius hemimyotomy.
Mouilhade, F, Matsoukis, J, Oger, P, Mandereau, C, Brzakala, V, Dujardin, F
Orthopaedics & traumatology, surgery & research : OTSR. 2011;(1):14-21
Abstract
INTRODUCTION One factor of implant survivorship in total hip replacement (THR) is the quality of implant choice and positioning. The purported advantages of minimally invasive approaches are faster recovery, shorter hospital stay and less per-operative blood loss. On the other hand, there have been many reports of higher complication rates, and doubts as to the quality of implant positioning. HYPOTHESIS The quest to minimize tissue damage is at the cost of THR positioning quality. OBJECTIVES To assess implant positioning in a prospective comparative continuous multicenter series. PATIENTS AND METHODS Between 2008 and 2009, a prospective comparative study was conducted on a continuous series of 141 THRs. Ninety-two were performed in two centers, using a minimally invasive Watson-Jones approach; the other 49, performed in a 3rd center, used an anterolateral approach with anterior hemimyotomy. The surgeons were in all cases experienced in their technique. Short-term follow-up comprised clinical and functional (Postel Merle d'Aubigné (PMA), Harris, SF12, WOMAC) and biological assessment (serum creatine phosphokinase (CPK), myoglobinemia, hematocrit) and analysis of complications and of implant positioning on X-ray and CT-scan. RESULTS On the Watson-Jones approach, surgery time was longer; day-1 analgesic administration was lower; PMA, Harris and WOMAC scores were better at 6 weeks; and CPK levels were lower at 24 and 48hours. There were no significant differences on the other clinical and biological criteria. Implant positioning analysis revealed significantly greater combined anteversion and greater variation in acetabular inclination mean with the Watson-Jones approach, but no differences in cup positioning, femoral stem positioning, or limb length discrepancy. DISCUSSION The minimally invasive Watson-Jones approach provided faster recovery and less muscular damage. However, implant positioning was less precise in terms of acetabular cup inclination. LEVEL OF EVIDENCE Level III. Prospective, comparative, non-randomized.