1.
Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences.
Suga, K, Yasuhiko, K, Zaki, M, Yamashita, T, Seto, A, Matsumoto, T, Matsunaga, N
European journal of nuclear medicine and molecular imaging. 2004;(2):240-9
Abstract
In this study, respiratory-gated ventilation and perfusion single-photon emission tomography (SPET) were used to define regional functional impairment and to obtain reliable co-registration with computed tomography (CT) images in various lung diseases. Using a triple-headed SPET unit and a physiological synchroniser, gated perfusion SPET was performed in a total of 78 patients with different pulmonary diseases, including metastatic nodules (n = 15); in 34 of these patients, it was performed in combination with gated technetium-99m Technegas SPET. Projection data were acquired using 60 stops over 120 degrees for each detector. Gated end-inspiration and ungated images were reconstructed from 1/8 data centered at peak inspiration for each regular respiratory cycle and full respiratory cycle data, respectively. Gated images were registered with tidal inspiration CT images using automated three-dimensional (3D) registration software. Registration mismatch was assessed by measuring 3D distance of the centroid of the nine selected round perfusion-defective nodules. Gated SPET images were completed within 29 min, and increased the number of visible ventilation and perfusion defects by 9.7% and 17.2%, respectively, as compared with ungated images; furthermore, lesion-to-normal lung contrast was significantly higher on gated SPET images. In the nine round perfusion-defective nodules, gated images yielded a significantly better SPET-CT match compared with ungated images (4.9 +/- 3.1 mm vs 19.0 +/- 9.1 mm, P<0.001). The co-registered SPET-CT images allowed accurate perception of the location and extent of each ventilation/perfusion defect on the underlying CT anatomy, and characterised the pathophysiology of the various diseases. By reducing respiratory motion effects and enhancing perfusion/ventilation defect clarity, gated SPET can provide reliable co-registered images with CT images to accurately characterise regional functional impairment in various lung diseases.
-
2.
Baseline/post-nitrate Tc-99m tetrofosmin mismatch for the assessment of myocardial viability in patients with severe left ventricular dysfunction: comparison with baseline Tc-99m tetrofosmin scintigraphy/FDG PET imaging.
Giorgetti, A, Marzullo, P, Sambuceti, G, Di Quirico, S, Kusch, A, Landi, P, Salvadori, PA, Pisani, P, L'abbate, A
Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2004;(2):142-51
Abstract
BACKGROUND Positron emission tomography (PET) flow/metabolic mismatch is considered the nuclear medicine gold standard for the assessment of myocardial viability. The aim of this study was to investigate whether baseline/nitrate technetium 99m tetrofosmin single photon emission computed tomography (SPECT) mismatch may provide equivalent clinical information. METHODS AND RESULTS We studied 23 patients (aged 62 +/- 10 years, 19 men) with previous myocardial infarction (16 anterior, 4 inferior, and 3 anterior plus inferior) and postischemic heart failure (gated SPECT [G-SPECT] ejection fraction, 26% +/- 8%). All patients underwent Tc-99m tetrofosmin G-SPECT at rest and after nitrates (intravenous isosorbide dinitrate, 0.2 mg/mL, 10 mL/h) as well as a fluorine 18 fluoro-2-deoxy-d-glucose (FDG) PET scan. Regional wall motion analysis was performed with quantitative G-SPECT (QGS). Myocardial dysfunction was defined as a regional QGS score of 2 or greater. Regional perfusion was assessed by quantitative perfusion score (QPS) providing percent Tc-99m tetrofosmin uptake in a 20-segment model. Semiquantitative analysis of FDG uptake was performed by use of polar maps generated by Siemens ECAT HR + software. In areas with a perfusion rate lower than 80%, PET viability was identified by a normalized FDG percent uptake/baseline Tc-99m tetrofosmin percent uptake ratio greater than 1.2. We analyzed 460 segments; 298 (64%) were dysfunctional by QGS analysis. Of these, 170 were viable by PET imaging whereas 128 were nonviable. Regional Tc-99m tetrofosmin uptake was higher in viable than in nonviable segments both at rest (60% +/- 24% vs 42% +/- 12%, P <.01) and after nitrates (67% +/- 20% vs 41% +/- 18%, P <.01). According to receiver operating characteristic curve analysis, a cutoff value of 63% for resting as well as post-nitrate G-SPECT provided the highest diagnostic accuracy for the detection of myocardial viability (67% and 72% at rest and after nitrates, respectively). When the same algorithm used for the comparison with PET (normalized nitrate percent uptake/baseline percent uptake) was applied to G-SPECT, we obtained the highest agreement with PET (accuracy, 93%; sensitivity, 95%; specificity, 92%). CONCLUSIONS In patients with severe left ventricular dysfunction, perfusion data alone, both at rest and after nitrates, do not allow an accurate estimate of myocardial viability. In dysfunctioning segments, the analysis of rest/post-nitrate Tc-99m tetrofosmin mismatch provides results similar to those obtained by PET flow/metabolic mismatch.
-
3.
Validation of an evaluation routine for left ventricular volumes, ejection fraction and wall motion from gated cardiac FDG PET: a comparison with cardiac magnetic resonance imaging.
Schaefer, WM, Lipke, CS, Nowak, B, Kaiser, HJ, Buecker, A, Krombach, GA, Buell, U, Kühl, HP
European journal of nuclear medicine and molecular imaging. 2003;(4):545-53
Abstract
The aim of this study was to validate the estimation of left ventricular end-diastolic and end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) as well as wall motion analysis from gated fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) in patients with severe coronary artery disease (CAD) using software originally designed for gated single-photon emission tomography (SPET). Thirty patients with severe CAD referred for myocardial viability diagnostics were investigated using a standard FDG PET protocol enhanced with gated acquisition (8 gates per cardiac cycle). EDV, ESV and LVEF were calculated using standard software designed for gated SPET (QGS). Wall motion was analysed using a visual four-point wall motion score on a 17-segment model. As a reference, all patients were also examined within a median of 3 days with cardiovascular cine magnetic resonance imaging (cMRI) (20 gates per cardiac cycle). Furthermore, all gated FDG PET data sets were reoriented in a second run with deliberately misaligned axes to test the quantification procedure for robustness. Correlation between the results of gated FDG PET and cMRI was very high for EDV and ESV ( R=0.96 and R=0.97) and for LVEF ( R=0.95). With gated FDG PET, there was a non-significant tendency to underestimate EDV (174+/-61 ml vs 179+/-59 ml, P=0.21) and to overestimate ESV (124+/-58 ml vs 122+/-60 ml, P=0.65), resulting in underestimated LVEF values (31.5%+/-9.4% vs 34.2%+/-12.4%, P<0.003). The results of reorientations 1 and 2 showed very high correlations (for all R≥0.99). Segmental wall motion analysis revealed good agreement between gated FDG PET data and cMRI (kappa =0.62+/-0.03). In conclusion, despite small systematic differences which contributed mainly to the lower temporal resolution of gated FDG PET, agreement between gated FDG PET and cMRI was good across a wide range of volumes and LVEF values as well as for wall motion analysis. Therefore, gated FDG PET provides clinically relevant information on function and volumes, using the commercially available software package QGS.
-
4.
Low-dose dobutamine stress gated SPET for identification of viable myocardium: comparison with stress-rest perfusion SPET and PET.
Yoshinaga, K, Katoh, C, Noriyasu, K, Yamada, S, Ito, Y, Kuge, Y, Kawai, Y, Kohya, T, Kitabatake, A, Tamaki, N
European journal of nuclear medicine and molecular imaging. 2002;(7):882-90
Abstract
The detection of viable myocardium is important for the prediction of functional recovery after revascularisation. However, a fixed perfusion defect often includes viable myocardium, and perfusion imaging then underestimates myocardial viability. We previously reported that low-dose dobutamine stress gated single-photon emission tomography (SPET) provides similar findings to dobutamine stress echocardiography in the assessment of myocardial viability. The present study investigated whether low-dose dobutamine stress gated SPET is of additional value as compared with stress-rest technetium-99m tetrofosmin SPET for the detection of myocardial viability. Standard stress-rest perfusion SPET, low-dose dobutamine stress gated SPET and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) were studied in 23 patients (mean age 67+/-7.6 years) with previous myocardial infarction. Twenty-one of them were successfully studied with each technique. FDG PET viability (FDG uptake ≥50%) was employed as the gold standard. One-day stress-rest (99m)Tc-tetrofosmin myocardial SPET was performed. After the resting study, gated SPET was acquired following infusion of 7.5 microg kg(-1) min(-1) of dobutamine. Left ventricular wall motion in 16 segments was assessed by cine mode display using a four-point scale. Myocardial viability was considered present when there was improvement by one point. Of a total of 336 segments analysed, 53 had persistent defects on stress-rest perfusion SPET. FDG viability was seen in 16 of 17 dobutamine-responsive segments, but in only 11 of 36 dobutamine non-responsive segments ( P<0.01). Thus, in the segments with persistent defects, viability findings on low-dose dobutamine stress gated SPET were concordant with those on FDG PET in 77% of segments (kappa value =0.55). For the detection of FDG-viable myocardium, the combination of stress-rest perfusion SPET and low-dose dobutamine stress gated SPET achieved a better sensitivity than stress-rest perfusion SPET alone (35/46, 76% vs 19/46, 41.3%, P<0.001), with a similar specificity (25/29, 86% vs 26/29, 90%, P=NS). We conclude that in the identification of viable myocardium, low-dose dobutamine stress gated SPET may provide additional information missed on a routine stress-rest perfusion scan. Dobutamine stress gated SPET may provide new insights into myocardial viability on the basis of ischaemia and contractile reserve.