1.
Pharmacomagnetography to evaluate the performance of magnetic enteric-coated tablets in the human gastrointestinal tract.
Pinto, LA, Corá, LA, Rodrigues, GS, Prospero, AG, Soares, GA, de Andreis, U, de Arruda Miranda, JR
European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V. 2021;:50-55
Abstract
A magnetic enteric-coated tablet containing diclofenac sodium was produced, and its performance under physiological and disturbed gastrointestinal motility was assessed through pharmacomagnetography analysis. In vitro studies were performed using conventional methods and in vivo studies were conducted on healthy volunteers before (control) and after domperidone administration. The magnetic tablet's gastrointestinal (GI) transit and disintegration process were monitored using the Alternating Current Biosusceptometry sensors combined with drug plasmatic concentration. The Gastric Residence Time, Colon Arrival Time, Small Bowel Transit Time, Disintegration Time and the pharmacokinetics parameters were calculated. The pH-dependent polymers used to coat the magnetic tablets were able to avoid the premature drug release on gastric or small intestine simulated medium. Gastric Residence Time was accelerated compared with the control group (p < 0.01). No significant differences were found regarding small bowel transit, colon arrival, disintegration process, or pharmacokinetics parameters. A strong correlation between magnetic monitoring and pharmacokinetics parameters analysis was determinant to evaluate the efficiency in the drug delivery at a specific site in the human gastrointestinal tract. In addition, a tablet with a damaged coating was used as a proof of concept to show the suitability of our methodology to evaluate the tablet. Our study showed that pharmacomagnetography is a multi-instrumental approach towards assessing drug delivery and bioavailability.
-
2.
Clinical hemocompatibility of double-filtration lipoprotein apheresis comparing polyethersulfone and ethylene-vinyl alcohol copolymer membranes.
Krieter, DH, Jeyaseelan, J, Rüth, M, Lemke, HD, Wanner, C, Drechsler, C
Artificial organs. 2021;(9):1104-1113
Abstract
Activation of the complement system and leukocytes by blood-membrane interactions may further promote arteriosclerosis typically present in patients on lipoprotein apheresis. As clinical data on the hemocompatibility of lipoprotein apheresis are scarce, a controlled clinical study comparing two different types of plasma separation and fractionation membranes used in double-filtration lipoprotein apheresis was urgently needed, as its outcome may influence clinical decision-making. In a prospective, randomized, crossover controlled trial, eight patients on double-filtration lipoprotein apheresis were subjected to one treatment with recent polyethersulfone (PES) plasma separation and fractionation membranes and one control treatment using a set of ethylene-vinyl alcohol copolymer (EVAL) membranes. White blood cell (WBC) and platelet (PC) counts, complement factor C5a and thrombin-antithrombin III (TAT) concentrations were determined in samples drawn at defined times from different sites of the extracorporeal blood and plasma circuit. With a nadir at 25 minutes, WBCs in EVAL decreased to 33.5 ± 10.7% of baseline compared with 63.8 ± 22.0% at 20 minutes in PES (P < .001). The maximum C5a levels in venous blood reentering the patients were measured at 30 minutes, being 30.0 ± 11.2 µg/L with EVAL and 12.3 ± 9.0 µg/L with PES (P < .05). The highest C5a concentrations were found in plasma after the plasma filters (EVAL 56.1 ± 22.0 µg/L at 15 minutes vs PES 23.3 ± 15.2 µg/L at 10 minutes; P < .001). PC did not significantly decrease over time with both membrane types, whereas TAT levels did not rise until the end of the treatment without differences between membranes. Regarding lipoprotein(a) and low-density lipoprotein (LDL) cholesterol removal, both membrane sets performed equally. Compared with EVAL, PES membranes cause less leukocyte and complement system activation, the classical parameters of hemocompatibility of extracorporeal treatment procedures, at identical treatment efficacy. Better hemocompatibility may avoid inflammation-promoting effects through blood-material interactions in patients requiring double-filtration lipoprotein apheresis.
-
3.
1-Year Clinical Outcomes of All Comers Treated With 2 Bioresorbable Polymer-Coated Sirolimus-Eluting Stents: Propensity Score-Matched Comparison of the COMBO and Ultrathin-Strut Orsiro Stents.
Chandrasekhar, J, Kok, MM, Kalkman, DN, Aquino, MB, Zocca, P, Woudstra, P, Beijk, MA, Kerkmeijer, LS, Sartori, S, Baber, U, et al
JACC. Cardiovascular interventions. 2020;(7):820-830
Abstract
OBJECTIVES The aim of this study was to determine 1-year safety and efficacy after treatment with the COMBO and Orsiro stents. BACKGROUND The COMBO stainless-steel stent has an anti-CD34+ antibody coating to capture endothelial progenitor cells, thereby promoting faster endothelialization. The Orsiro is an ultrathin-strut cobalt-chromium stent, covered by an extremely thin layer of amorphous silicon carbide to minimize ion leakage. Both devices elute sirolimus from biodegradable polymers. METHODS For this analysis we included European patients from the COMBO collaboration, a patient-level pooling of 2 prospective all-comers registries of COMBO stent implantation (n = 2,775), and all patients randomized to the Orsiro stent (n = 1,169) from the Dutch BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) randomized trial. The main outcome of interest was 1-year target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization evaluated using propensity score-matched analysis. RESULTS At baseline, COMBO patients were older and had more insulin-treated diabetes, renal insufficiency, and other comorbidities. However, Orsiro patients included more current smokers and more acute coronary syndrome presentations. Orsiro patients also received longer stents and had more complex target lesions. After propensity score-matched analysis (n = 862/arm), 1-year target lesion failure occurred in 4.1% of COMBO-treated and 2.7% of Orsiro-treated patients (hazard ratio: 1.55; 95% confidence interval: 0.92 to 2.62; p = 0.10). Definite stent thrombosis occurred in 0.5% of COMBO-treated and 0.5% of Orsiro-treated patients (p = 0.99). CONCLUSIONS A propensity score-matched comparison of all comers treated with the COMBO or Orsiro stent showed no statistically significant differences. Stent thrombosis risk was low and similar between the stents. (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population [BIO-RESORT], NCT01674803; MASCOT-Post Marketing Registry [MASCOT], NCT02183454; Prospective Registry to Assess the Long-term Safety and Performance of the Combo Stent [REMEDEE Reg], NCT01874002).
-
4.
Everolimus-Eluting Versus Biolimus-Eluting Stents With Biodegradable Polymers in Unselected Patients Undergoing Percutaneous Coronary Intervention: A Randomized Noninferiority Trial With 1-Year Follow-Up (SORT OUT VIII Trial).
Maeng, M, Christiansen, EH, Raungaard, B, Kahlert, J, Terkelsen, CJ, Kristensen, SD, Carstensen, S, Aarøe, J, Jensen, SE, Villadsen, AB, et al
JACC. Cardiovascular interventions. 2019;(7):624-633
Abstract
OBJECTIVES The aim of this study was to compare the thin-strut biodegradable-polymer everolimus-eluting platinum-chromium stent (EES) with the biodegradable-polymer biolimus-eluting stainless-steel stent (BES). BACKGROUND Currently available drug-eluting coronary stents have been refined to reduce the risk for coronary events following implantation. METHODS This randomized, multicenter, all-comers, noninferiority trial was undertaken at 3 sites in western Denmark. Patients with clinical indications for percutaneous coronary intervention were eligible for inclusion. Patients were randomly assigned (1:1) to either EES or BES. The primary endpoint, target lesion failure, was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a nontarget lesion) and efficacy (target lesion revascularization) at 12 months, analyzed using intention-to-treat principles. The trial was powered to assess target lesion failure noninferiority of the EES compared with the BES with a predetermined noninferiority margin of 3%. RESULTS A total of 1,385 patients were assigned to treatment with EES and 1,369 patients to treatment with BES. The analysis showed that 55 patients (4.0%) assigned to the EES and 60 (4.4%) assigned to the BES met the primary endpoint (absolute risk difference 0.4%; upper limit of 1-sided 95% confidence interval: 1.7%; p < 0.001). CONCLUSIONS At 1-year follow-up, the EES was found to be noninferior to the BES with respect to target lesion failure. (Everolimus-eluting SYNERGY Stent Versus Biolimus-Eluting Biomatrix NeoFlex Stent-SORT-OUT VIII; NCT02093845).
-
5.
Thin, Very Thin, or Ultrathin Strut Biodegradable or Durable Polymer-Coated Drug-Eluting Stents: 3-Year Outcomes of BIO-RESORT.
Buiten, RA, Ploumen, EH, Zocca, P, Doggen, CJM, Danse, PW, Schotborgh, CE, Scholte, M, van Houwelingen, KG, Stoel, MG, Hartmann, M, et al
JACC. Cardiovascular interventions. 2019;(17):1650-1660
Abstract
OBJECTIVES The aim of this study was to assess the 3-year safety and efficacy of treating all-comer patients with 3 contemporary drug-eluting stents (DES). BACKGROUND The BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) (TWENTE III) randomized trial (NCT01674803) found similar 1-year safety and efficacy for the 2 biodegradable-polymer DES (i.e., ultrathin-strut cobalt-chromium Orsiro sirolimus-eluting stent [SES] and very-thin-strut platinum-chromium Synergy everolimus-eluting stent) compared with the durable-polymer thin-strut cobalt-chromium Resolute Integrity zotarolimus-eluting stent (ZES). Two-year follow-up suggested that the SES might reduce repeat revascularizations beyond 1 year compared with the ZES. METHODS A total of 3,514 all-comer patients were treated at 4 centers for coronary intervention. The main clinical endpoint, target vessel failure, was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularization). Secondary endpoints included the individual components of target vessel failure and stent thrombosis. RESULTS Three-year follow-up data were available for 3,393 of 3,514 patients (96.6%). Target vessel failure occurred in 8.5% with SES and 10.0% with ZES (plog rank = 0.22) and in 8.8% with everolimus-eluting stents (vs. ZES, plog rank = 0.32). Rates of cardiac death, target vessel myocardial infarction, and target vessel revascularization were similar between stent groups. Landmark analyses found no statistically significant between-stent difference in repeat revascularization between 1 and 3 years. Definite or probable stent thrombosis rates were low (SES, 1.1%; everolimus-eluting stent, 1.1%; ZES, 0.9%) and similar with all 3 DES. CONCLUSIONS Despite substantial differences in stent backbone and polymer coating, all 3 DES showed favorable 3-year safety and efficacy in all comers, without significant between-stent differences. Further follow-up is required to definitely answer the question of whether one stent might improve clinical outcomes at a later stage.
-
6.
Subgroup Analysis Comparing Ultrathin, Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin, Durable Polymer Everolimus-Eluting Stents in Acute Coronary Syndrome Patients.
Roguin, A, Kandzari, DE, Marcusohn, E, Koolen, JJ, Doros, G, Massaro, JM, Garcia-Garcia, HM, Bennett, J, Gharib, EG, Cutlip, DE, et al
Circulation. Cardiovascular interventions. 2018;(10):e007331
Abstract
BACKGROUND Presentation with acute coronary syndromes (ACS) constitutes a high-risk subset of patients with worse outcome after percutaneous coronary intervention. We report clinical outcomes in subjects with ACS from the BIOFLOW V trial (BIOTRONIK - A Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With up to Three De Novo or Restenotic Coronary Artery Lesions) comparing an ultrathin strut (60 μm) bioresorbable polymer sirolimus-eluting stent (BP-SES) with a thin strut (81 μm) durable polymer everolimus-eluting stent (DP-EES). METHODS AND RESULTS Among 1334 patients randomized to 2:1 treatment with either BP-SES or DP-EES, 677 (50.7%) ACS patients without ST-segment-elevation myocardial infarction (MI; 454 BP-SES and 223 DP-EES) were identified in the retrospective post hoc analysis. The primary end point of 12-month target lesion failure, individual component end points, and stent thrombosis were evaluated. Recurrent MI was defined as a ≥50% increase of creatine kinase-myocardial band or in the absence of creatine kinase-myocardial band, troponin >50% increase over previous level and >3× the upper limit of normal). All events were adjudicated by a blinded independent clinical events committee. Overall, baseline clinical, angiographic, and procedural characteristics of the ACS population were similar between the 2 treatment groups. At 12 months, target lesion failure occurred in 5.6% (24/426) of BP-SES patients versus 11.0% (23/209) in DP-EES patients ( P=0.02); target lesion failure composite components were cardiac death, 0% versus 1.0% ( P=0.11); target vessel-related MI, 3.5% versus 9.7% ( P=0.003); and clinically driven target lesion revascularization, 2.8% versus 3.4% ( P=0.80). Spontaneous target vessel MI was 0.5% (2/425) for BP-SES versus 2.4% (5/206) for DP-EES ( P=0.041). Stent thrombosis rates at 1 year were similar (0.5% versus 1.0%; P=0.601). CONCLUSIONS In the ACS subgroup population of the BIOFLOW V study, treatment with BP-SES compared with DP-EES was associated with a significantly lower rate of 12-month target lesion failure, a difference driven by significantly lower periprocedural MI and spontaneous MI. These findings support treatment with an ultrathin strut BP-SES in ACS patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov . Unique identifier: NCT02389946.
-
7.
Comparison of primary human gingival fibroblasts from an older and a young donor on the evaluation of cytotoxicity of denture adhesives.
Soares, ASLS, Scelza, MZ, Spoladore, J, Gallito, MA, Oliveira, F, Moraes, RCM, Alves, GG
Journal of applied oral science : revista FOB. 2018;:e20160594
Abstract
UNLABELLED Denture adhesives (DA) improve the retention and stability of ill-fitting dentures, especially for older adults. These materials should be biocompatible, i.e., they cannot cause undesired biological responses and be non-cytotoxic to oral tissues. However, in vitro testing of DA biocompatibility employing primary cell culture may possibly be affected by other factors, such as the donor age. OBJECTIVE To compare the cytotoxicity of three different denture adhesives when assessed in primary gingival fibroblasts from a young donor or from an older donor, as well as the release of the basic fibroblast growth factor (bFGF), and the inflammatory response marker interleukin-6 (IL-6). MATERIAL AND METHODS Gingival fibroblasts isolated from a 30- and a 62-year-old donor were assayed for proliferation (1-7 days) and sensitivity to latex (positive control). Fibroblasts were indirectly exposed to Corega Ultra (cream), Corega powder and Fixodent Original for a 24 h period and assayed by XTT and Crystal Violet tests. The release of IL-6 and bFGF by exposed cells was determined by ELISA. RESULTS While cells from the young donor presented higher cell growth after 7 days, the sensitivity to increasing concentrations of latex extracts was very similar between young and older cells. Both XTT and CVDE detected no difference between the DA and the control group. All materials induced higher levels of IL-6 and bFGF compared to control. Cells from the older donor exposed to Corega Ultra released lower levels of cytokine and growth factor. CONCLUSIONS All materials were considered non-cytotoxic, but affected cytokine and growth factor release. The biological differences found between fibroblasts from both donors could be due to individual or age-related factors. The authors suggest the use of cells from older donors on studies of dental products aimed at older patients, to better simulate their physiological response.
-
8.
Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: The SORT OUT VII Trial.
Jensen, LO, Thayssen, P, Maeng, M, Ravkilde, J, Krusell, LR, Raungaard, B, Junker, A, Terkelsen, CJ, Veien, KT, Villadsen, AB, et al
Circulation. Cardiovascular interventions. 2016;(7)
Abstract
BACKGROUND Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. METHODS AND RESULTS The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial-a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial-compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt-chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, -0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P<0.0001). Rates of definite stent thrombosis occurred in 5 (0.4%) of the sirolimus-eluting group compared with 15 (1.2%) biolimus-eluting stent-treated patients (rate ratio, 0.33; 95% confidence interval, 0.12-0.92; P=0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02-1.00; P=0.05). CONCLUSIONS The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01879358.
-
9.
Comparison of denitrification performances using PLA/starch with different mass ratios as carbon source.
Wu, C, Tang, D, Wang, Q, Wang, J, Liu, J, Guo, Y, Liu, S
Water science and technology : a journal of the International Association on Water Pollution Research. 2015;(7):1019-25
Abstract
A suitable carbon source is significant for biological nitrate removal from groundwater. In this study, slow-release carbon sources containing polylactic acid (PLA) and starch at 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7 ratios were prepared using a blending and fusing technique. The PLA/starch blend was then used as a solid carbon source for biological nitrate removal. The carbon release rate of PLA/starch was found to increase with increased starch content in leaching experiments. PLA/starch at 5:5 mass ratio was found to have the highest denitrification performance and organic carbon consumption efficiency in semi-continuous denitrification experiments, and was also revealed to support complete denitrification at 50 mg-N/L influent nitrate concentration in continuous experiments. The effluent nitrate concentration was <2 mg NO(3)(-)-N/L, which met the national standard (GB 14848-93) for groundwater. Scanning electron microscopy results further showed that the surface roughness of PLA/starch increased with prolonged experimental time, which may be conducive to microorganism attachment. Therefore, PLA/starch was a suitable carbon source and biofilm carrier for groundwater remediation.
-
10.
Rationale and study design of the RESERVOIR trial: a randomized trial comparing reservoir-based polymer-free amphilimus-eluting stents versus everolimus-eluting stents with durable polymer in patients with diabetes mellitus.
Romaguera, R, Brugaletta, S, Gomez-Lara, J, Pinar, E, Jiménez-Quevedo, P, Gracida, M, Roura, G, Ferreiro, JL, Teruel, L, Gómez-Hospital, JA, et al
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2015;(4):E116-22
Abstract
BACKGROUND Patients with diabetes mellitus (DM) remain at high risk for stent restenosis and adverse cardiovascular events in the drug-eluting stent era. The amphilimus-eluting stent (AES) is a third generation reservoir-based polymer-free drug-eluting stent that has shown promising preliminary results in patients with DM. It has been suggested that the formulation of the drug with fatty acids could not only modulate the drug release in a timely manner but also achieve convenient levels of drug concentration in diabetic cardiac cells. The aim of this trial is to assess the efficacy of the AES in patients with DM compared with the cobalt chromium everolimus-eluting stent with non-erodible polymer (EES). STUDY DESIGN This is an investigator-initiated, multicenter, randomized clinical trial, performed in patients with DM. A total of 112 diabetic patients receiving glucose-lowering agents and requiring percutaneous revascularization of a de novo lesion will be randomized in a 1:1 fashion to receive AES or EES. The primary endpoint is the neointimal volume obstruction at 9 months, evaluated by optical coherence tomography. Secondary endpoints will include strut coverage, angiographic in-stent late loss and clinical endpoints such as target vessel revascularization or probable/definite stent thrombosis. This study completed the inclusion in October 2013. CONCLUSIONS The RESERVOIR trial is an investigator-initiated trial that will evaluate whether the polymer-free AES is not inferior to the EES inhibiting the neointimal hyperplasia in patients with DM. These results are also expected to improve our knowledge of the neointimal healing process in this population (Clinicaltrials.gov number NCT01710748).