1.
Highly sensitive microcantilever-based immunosensor for the detection of carbofuran in soil and vegetable samples.
Dai, Y, Wang, T, Hu, X, Liu, S, Zhang, M, Wang, C
Food chemistry. 2017;:432-438
Abstract
Microcantilever-based immunosensor is a next-generation electromechanical technique with broad application in biological detection. In this paper, we reported a microcantilever-based immunosensor that quantitatively detect the carbofuran, by using monoclonal antibodies to carbofuran as the receptor molecules. The surface of gold-coated microcantilever was chemically modified by the crosslinking of l-cysteine (l-cys)/glutaraldehyde (GA). The monoclonal antibodies to carbofuran were then immobilized on the side of the microcantilever to fabricate the immunosensor, the mechanical bending induced by antigen-antibody specific binding under an experimental environment. Under the optimized conditions, immunosensor detected carbofuran showed a good linear relationship over the range from 1.0×10-7 to 1.0×10-3g/L (R=0.998), with a detection limit of 0.1ng/mL. Moreover, the proposed immunosensor exhibited high sensitivity, specificity and good stability and can be successfully applied in the carbofuran determination in soil and vegetable samples with satisfactory results.
2.
Nanostructured photoelectrochemical biosensor for highly sensitive detection of organophosphorous pesticides.
Li, X, Zheng, Z, Liu, X, Zhao, S, Liu, S
Biosensors & bioelectronics. 2015;:1-5
Abstract
A sensitive photoelectrochemical (PEC) biosensor for detection of organophosphorus pesticides (OPs) using the nanocomposite of CdSe@ZnS quantum dots (QDs) and graphene deposited on the ITO coated glass electrode as a photoactive electrode is presented. The integration of CdSe@ZnS/graphene nanocomposite with biomolecules acetylcholinesterase (AChE) as a biorecognition element yields a novel biosensing platform. Under visible light irradiation, the AChE-CdSe@ZnS/graphene nanocomposite can generate a stable photocurrent and the photocurrent is found to be inversely dependent on the concentration of OPs. Under the optimal experimental conditions, the photocurrents were proportional to the logarithm of paraoxon and dichlorvos within the concentration range of 10(-12)-10(-6) M. The detection limits (LOD) of the proposed biosensor for paraoxon and dichlorvos are as low as 10(-14) M and 10(-12) M. The photoelectrochemical biosensor shows good sensitivity, reproducibility, stability, and could be successfully applied to detection of OPs in real fruit samples.