1.
The incidence of radioepidermitis and the dose-response relationship in parotid gland cancer patients treated with 125I seed brachytherapy: incidence of radioepidermitis and the dose-response relationship.
Mao, MH, Zhang, JG, Zheng, L, Gao, H, Zhang, J, Liu, SM, Huang, MW, Shi, Y
Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. 2015;(1):26-33
Abstract
BACKGROUND We studied the incidence and dose-response relationship of radioepidermitis in parotid gland carcinoma patients treated with [(125)I] seed brachytherapy in the hopes of designing an optimized pre-implant treatment plan that would reduce the incidence and severity of radioepidermitis in patients receiving this therapy. PATIENTS AND METHODS Between January 2007 and May 2010, 100 parotid gland cancer patients were treated postoperatively with [(125)I] seed brachytherapy. The matched peripheral dose (MPD) was 80-140 Gy, and [(125)I] seed activity was 0.7-0.8 mCi. The mean dose delivered to the skin was calculated in the post-implant CT on day 0 following implantation. Grades of acute and late dermatitis were evaluated at 2, 6, 12, and 18 months post-implantation. RESULTS Most patients experienced grade 0-2 acute and late skin side effects (86 and 97%, respectively), though a small subset developed severe complications. Most grade 1-3 effects resolved within 6 months of implantation, though some grade 1-3 effects and all grade 4 effects remained unchanged throughout the 18-month follow-up period. Grade 3 and 4 effects were most prominent (75 and 25%, respectively) with doses of 110-140 Gy; doses higher than 140 Gy produced only grade 4 effects. CONCLUSION [(125)I] seed brachytherapy produced acceptable levels of acute and late radioepidermitis with a good clinical outcome. A mean dose under 100 Gy delivered to the skin was safe, though doses of 110-140 Gy should be given with caution and extra monitoring; doses greater than 140 Gy are dangerous and likely to produce grade 4-5 effects.
2.
A digital model individual template and CT-guided 125I seed implants for malignant tumors of the head and neck.
Huang, MW, Liu, SM, Zheng, L, Shi, Y, Zhang, J, Li, YS, Yu, GY, Zhang, JG
Journal of radiation research. 2012;(6):973-7
-
-
Free full text
-
Abstract
To enhance the accuracy of radioactive seed implants in the head and neck, a digital model individual template, containing information simultaneously on needle pathway and facial features, was designed to guide implantation with CT imaging. Thirty-one patients with recurrent and local advanced malignant tumors of head and neck after prior surgery and radiotherapy were involved in this study. Before (125)I implants, patients received CT scans based on 0.75mm thickness. And the brachytherapy treatment planning system (BTPS) software was used to make the implantation plan based on the CT images. Mimics software and Geomagic software were used to read the data containing CT images and implantation plan, and to design the individual template. Then the individual template containing the information of needle pathway and face features simultaneously was made through rapid prototyping (RP) technique. All patients received (125)I seeds interstitial implantation under the guide of the individual template and CT. The individual templates were positioned easily and accurately, and were stable. After implants, treatment quality evaluation was made by CT and TPS. The seeds and dosages distribution (D(90),V(100),V(150)) were well meet the treatment requirement. Clinical practice confirms that this approach can facilitate easier and more accurate implantation.