-
1.
Effect of continuous nursing on angina attack and quality of life in patients with coronary artery disease: A protocol for systematic review and meta-analysis.
Zhou, X, Yuan, Y, Wang, Z, Zhang, K, Fan, W, Zhang, Y, Ma, P
Medicine. 2021;(5):e24536
-
-
Free full text
-
Abstract
BACKGROUND Coronary Artery Disease is an ischemic or necrotic heart disease caused by myocardial hypoxia caused by coronary artery stenosis or occlusion. The main symptoms are heart failure and recurrent angina pectoris. Continuous nursing refers to the nursing mode from in-hospital nursing to out-of-hospital nursing, including guiding patients' follow-up treatment and lifestyle, which can effectively improve the quality of life in patients with Coronary Artery Disease and reduce the number of angina attacks. The study implemented in this program will systematically evaluate the efficacy and safety of continuous nursing intervention on an angina attack and quality of life in Coronary Artery Disease, and provide evidence-based basis for clinical application of continuous nursing intervention in Coronary Artery Disease. METHOD The 2 researchers search the databases of China Knowledge Network, VP Information Chinese Journal Service Platform, PubMed, Embase, the Cochrane Library and Web of Science. From the establishment of the database in December 2020, all the randomized controlled trials on continuous nursing intervention for Coronary Artery Disease are collected. The relevant data are extracted and the quality is evaluated. meta-analysis is performed on the included literature using Stata15.0 software. RESULT In this study, the efficacy and safety of continuous nursing intervention on Coronary Artery Disease are evaluated by Seattle angina questionnaire and other indicators. CONCLUSION This study will provide reliable evidence for the clinical application of nursing intervention in Coronary Artery Disease. ETHICS AND DISSEMINATION Private information from individuals will not be published. This systematic review also does not involve endangering participant rights. Ethical approval will not be required. The results may be published in a peer-reviewed journal or disseminated at relevant conferences. OSF REGISTRATION NUMBER DOI 10.17605/OSF.IO/7QRKV.
-
2.
Predictive value of coronary artery calcium score in cardiovascular disease.
Liu, S, Zheng, X, Xu, J, Wang, X, Zhang, Y, Lv, B, Zheng, L, Sun, K
Frontiers in bioscience (Elite edition). 2020;(1):113-125
Abstract
We investigated coronary heart disease (CHD) and cardiovascular disease (CVD) event rates in a diverse population with a coronary artery calcium score (CACS) of 0 and the role of CACS in the detection of subclinical noncalcified atherosclerotic plaque. A total of 15,884 participants in five studies were included in this meta-analysis. Hazard ratios (HRs) with 95% confidence intervals (95% CIs) were calculated. The results showed that CHD incidence significantly increased with increased CACS (HR=0.05, 95% CI 0.03-0.06, Z=5.82, P=0.002). The CHD rate was low and further increased with CACS of 101-300. With CACS >300, the CHD rate was highest. Similarly, CVD rate was low with CACS of 0, increased with CACS of 1-100 (HR=0.03, 95% CI 0.01-0.06, Z=1.66, P=0.096), and further increased with CACS of 101-300. With CACS >300, the CVD rate was highest. Clinical evidence indicated that the higher the CACS, the higher the CHD and CVD rates, while the CVD rate does not always decreased compared with CHD rate with the same CACS, especially with CACS of 0.
-
3.
Epicardial Fat Volume Improves the Prediction of Obstructive Coronary Artery Disease Above Traditional Risk Factors and Coronary Calcium Score.
Zhou, J, Chen, Y, Zhang, Y, Wang, H, Tan, Y, Liu, Y, Huang, L, Zhang, H, Ma, Y, Cong, H
Circulation. Cardiovascular imaging. 2019;(1):e008002
Abstract
BACKGROUND Recent studies have demonstrated the tremendous potential of epicardial fat volume (EFV) to predict obstructive coronary artery disease. We aimed to develop a new model to estimate pretest probability of obstructive coronary artery disease using traditional risk factors with coronary calcium score and EFV and compare it with proposed models in Chinese patients who underwent coronary computed tomography angiography. METHODS The new models were derived from 5743 consecutive patients using multivariate logistic regression and validated in an internal cohort using invasive coronary angiography as the outcome and an external cohort with clinical outcome data. Hosmer-Lemeshow goodness-of-fit test, area under the receiver operating characteristic curve, integrated discrimination improvement and net reclassification improvement were calculated to validate and compare the performance of models. RESULTS EFV improved prediction above conventional risk factors and coronary calcium score (area under the receiver operating characteristic curve increased from 0.856 to 0.874, integrated discrimination improvement 0.0487, net reclassification improvement 0.1181, P<0.0001 for all). The final model included 5 predictors: age, sex, symptom, coronary calcium score, and EFV. Good internal validation and external validation of the new model were achieved, with positive net reclassification improvement and integrated discrimination improvement, excellent area under the receiver operating characteristic curve and favorable calibration. Further, the new model demonstrated a better prediction of clinical outcome, resulting in a more cost-effective risk stratification to optimize decision-making of downstream diagnosis and treatment. CONCLUSIONS Addition of EFV to conventional risk factors and coronary calcium score offered a more accurate and effective estimation for pretest probability of obstructive coronary artery disease, which may help to improve initial management of stable chest pain.
-
4.
Coronary calcium score improves the estimation for pretest probability of obstructive coronary artery disease and avoids unnecessary testing in individuals at low extreme of traditional risk factor burden: validation and comparison of CONFIRM score and genders extended model.
Wang, M, Liu, Y, Zhou, X, Zhou, J, Zhang, H, Zhang, Y
BMC cardiovascular disorders. 2018;(1):176
Abstract
BACKGROUND Reliability of models for estimating pretest probability (PTP) of obstructive coronary artery disease (CAD) has not been investigated in individuals at low extreme of traditional risk factor (RF) burden. Thus, we sought to validate and compare CONFIRM score and Genders extended model (GEM) among these individuals. METHODS We identified symptomatic individuals with 0 or 1 RF who underwent coronary calcium scan and coronary computed tomographic angiography (CCTA). Follow-up clinical data were also recorded. PTP of obstructive CAD for every individual was estimated according to CONFIRM score and GEM, respectively. Area under the receiver operating characteristic curve (AUC), integrated discrimination improvement (IDI), net reclassification improvement (NRI) and Hosmer-Lemeshow (H-L) test were used to assess the performance of models. RESULTS There were 1201 individuals with 0 RF and 2415 with 1 RF. The AUC for GEM was significantly larger than that for CONFIRM score, no matter in individuals with 0 (0.843 v.s. 0.762, p < 0.0001) or 1 (0.823 v.s. 0.752, p < 0.0001) RF. Compared to CONFIRM score, GEM demonstrated positive IDI (5% in individuals with 0 RF and 8% in individuals with 1 RF), positive NRI (41.50% in individuals with 0 RF and 40.19% in individuals with 1 RF), better prediction of clinical events and less discrepancy between observed and predicted probabilities, resulting in a significant decrease of unnecessary testing, especially in negative individuals. CONCLUSION In individuals at low extreme of traditional RF burden of CAD, the addition of coronary calcium score provided a more accurate estimation for PTP and application of GEM instead of CONFIRM score could avoid unnecessary testing.
-
5.
Fibrinogen and the Severity of Coronary Atherosclerosis among Adults with and without Statin Treatment: Lipid as a mediator.
Zhang, Y, Zhu, CG, Guo, YL, Li, S, Xu, RX, Dong, Q, Li, JJ
Heart, lung & circulation. 2016;(6):558-67
Abstract
BACKGROUND It has been proposed that plasma fibrinogen is associated with lipid levels and increased cardiovascular risk. However, the interrelationship has not been well-elucidated. We hypothesise that lipids may be potential mediators. METHODS We enrolled 4748 consecutive subjects scheduled for coronary angiography in this study. The severity of coronary atherosclerosis was assessed by Gensini score (GS). By principle component analysis, a multi-marker lipid index was extracted weighting the coefficients of six atherogenic lipid parameters: total cholesterol (TC), low-density lipoprotein-cholesterol, non-high-density lipoprotein-cholesterol (non-HDL-C), apolipoprotein (apo) B, apoB/apoA1, and TC/HDL-C ratio. Moreover, using mediation analysis, the relationship between fibrinogen and lipids with high GS was evaluated. RESULTS Fibrinogen was positively associated with GS after adjustment (β=0.100, p<0.001). We stratified our analyses by statin use status and found that subjects in the upper fibrinogen tertiles had higher levels of atherogenic lipid parameters irrespective of statin status (p<0.001, all). Significantly, we observed a synergistic effect of fibrinogen and concurrent elevated lipid index for high GS. The adjusted odds ratios were greater in participants who had high fibrinogen levels and also high lipid index compared to those with low lipid index [on statin: 1.725(1.258-2.364) vs. 1.261(0.962-1.652); not on statin: 2.197(1.450-3.328) vs. 1.166(0.417-3.258)]. Specifically, mediation analysis indicated that around 24% of the effect of fibrinogen on high GS was mediated by lipid index, which was attenuated to 13% by statin status. CONCLUSIONS The increased risk of fibrinogen on coronary atherosclerosis appeared to be enhanced by the high atherogenic lipid levels, which mediated around 24% of this effect.
-
6.
Non-HDL-C is a Better Predictor for the Severity of Coronary Atherosclerosis Compared with LDL-C.
Zhang, Y, Wu, NQ, Li, S, Zhu, CG, Guo, YL, Qing, P, Gao, Y, Li, XL, Liu, G, Dong, Q, et al
Heart, lung & circulation. 2016;(10):975-81
Abstract
BACKGROUND Recent guidelines recommended both low-density lipoprotein cholesterol (LDL-C) and non-high-density lipoprotein cholesterol (non-HDL-C) are the primary target of lipid modulating therapy. However, which lipid measure is most closely related to the severity of coronary atherosclerosis has not yet been assessed. METHODS We studied 1757 consecutive subjects undergoing coronary angiography who were not receiving any lipid-lowering therapy. Low-density lipoprotein cholesterol was measured directly, and non-HDL-C was calculated. The severity of coronary stenosis was determined using the Gensini Score (GS) system. RESULTS In the overall population, LDL-C and non-HDL-C were all dramatically increased according to the quartiles of GS (p<0.001, both). In patients with coronary atherosclerosis (n=1097), non-HDL-C (r=0.138, p<0.001) was more closely related to GS than LDL-C (r=0.113, p<0.001) tested by Spearman correlation analysis. Multivariate logistic regression analysis suggested that non-HDL-C (OR=1.326, 95% CI 1.165-1.508, p<0.001) was slightly superior to LDL-C (OR=1.286, 95% CI 1.130-1.463, p<0.001) in predicting high GS after adjusting for potential confounders. Among patients with LDL-C less than the median, discordant non-HDL-C could not provide extra value in predicting high GS (OR=0.759, 95% CI 0.480-1.201). However, among patients with LDL-C greater than or equal to the median, the cardiovascular risk was overestimated for patients with discordant non-HDL-C (OR=0.458, 95% CI 0.285-0.736). CONCLUSIONS Our data support the use of non-HDL-C ahead of LDL-C in predicting the severity of coronary atherosclerosis, especially among patients with LDL-C greater than or equal to the median.
-
7.
Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: a comparative study.
Cao, JX, Wang, YM, Lu, JG, Zhang, Y, Wang, P, Yang, C
European journal of radiology. 2014;(2):309-14
Abstract
OBJECTIVE To investigate the effects of 80-kilovoltage (kV) tube voltage coronary computed tomographic angiography (CCTA) with a reduced amount of contrast agent on qualitative and quantitative image quality parameters and on radiation dose in patients with a body mass index (BMI) <23.0 kg/m(2). METHODS One hundred and twenty consecutive patients with a BMI <23.0 kg/m(2) and a low calcium load undergoing retrospective electrocardiogram (ECG)-gated dual-source CCTA were randomized into two groups [standard-tube voltage (120-kV) vs. low-tube voltage (80-kV)]. The injection flow rate of contrast agent (350 mg I/mL) was adjusted to body weight of each patient (4.5-5.5 mL/s in the 120-kV group and 2.8-3.8 mL/s in the 80-kV group). Radiation and contrast agent doses were evaluated. Quantitative image quality parameters and figure of merit (FOM) of coronary artery were evaluated. Each coronary segment was evaluated for image quality on a 4-point scale. RESULTS Compared with the 120-kV group, effective dose and amount of contrast agent in the 80-kV group were decreased by 57.8% and 30.5% (effective dose:2.7 ± 0.5 vs. 6.4 ± 1.3 mSv; amount of contrast agent:57.1 ± 3.2 vs. 82.1 ± 6.1 mL; both p<0.0001), respectively. Image noise was 22.7 ± 2.1HU for 120-kV images and 33.2 ± 5.2 HU for 80-kV images (p<0.0001). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the proximal right coronary artery (RCA) and left main coronary artery (LMA) were all lower in 80-kV than 120-kV images (SNR in the proximal RCA: 16.5 ± 1.8 vs. 19.4 ± 2.8; SNR in the LMA: 16.3 ± 2.0 vs.19.6 ± 2.7; CNR in the proximal RCA: 19.4 ± 2.3 vs.22.9 ± 3.0; CNR in the LMA: 18.8 ± 2.4 vs. 22.7 ± 2.9; all p<0.0001). FOM were all significantly higher in 80-kV than 120-kV images (proximal RCA: 146.7 ± 45.1 vs. 93.4 ± 32.0; LMA: 139.1 ± 47.2 vs. 91.6 ± 31.1; all p<0.0001). There was no significant difference in image quality score between the two groups (3.3 ± 0.8 vs. 3.3 ± 0.8, p=0.068) despite decreased SNR and CNR of coronary artery in the 80-kV group. CONCLUSION The 80-kV protocol significantly reduces radiation and contrast agent doses in CCTA in patients with a low BMI <23.0 kg/m(2) and a low calcium load while maintaining image quality.