1.
Management of glucose profile throughout strict COVID-19 lockdown by patients with type 1 diabetes prone to hypoglycaemia using sensor-augmented pump.
Viñals, C, Mesa, A, Roca, D, Vidal, M, Pueyo, I, Conget, I, Giménez, M
Acta diabetologica. 2021;(3):383-388
-
-
Free full text
-
Abstract
AIMS: Spain has been one of the worst affected countries by the COVID-19 pandemic. A very strict lockdown at home was imposed with a tough restriction of mobility. We aimed to evaluate the impact of this exceptional scenario on glucose profile of patients with type 1 diabetes (T1D) prone to hypoglycaemia using sensor-augmented pump (SAP). METHODS Patients with T1D prone to hypoglycaemia using SAP (640G Medtronic-Minimed®) for at least 6 months under the funding of a National Health Service were included in an observational, retrospective study. Data were collected in two periods: pre-lockdown (PL), February 23rd-March 7th and within lockdown (WL), April 1st to 14th 2020. The primary outcome was the difference in the proportion of time in target glucose range of 70-180 mg/dL (TIR). Additional glucometric data and total daily insulin were also analysed. RESULTS Fifty-nine patients were included: 33 women, age 46.17 ± 13.0 years and disease duration of 30.2 ± 12.0 years. TIR 70-180 mg/dL (67.6 ± 11.8 vs. 69.8 ± 12.0%), time > 180 (28.1 ± 13.6 vs. 25.5 ± 13.1%), time > 250 (6.9 ± 6.1 vs. 5.1 ± 4.8) and estimated HbA1c (6.94 ± 0.8 vs. 6.75 ± 0.7%) significantly improved (PL vs. WL, respectively, p < 0.05). Time in hypoglycaemia, coefficient of variation, sensor usage and total daily insulin dose remained unchanged. CONCLUSIONS Lockdown conditions imposed by the COVID-19 pandemic may be managed successfully in terms of glycaemia control by population with DT1 prone to hypoglycaemia using SAP. The strict daily routine at home could probably explain the improvement in the time in glycemic target without increasing the time hypoglycaemia.
2.
The impact of strict COVID-19 lockdown in Spain on glycemic profiles in patients with type 1 Diabetes prone to hypoglycemia using standalone continuous glucose monitoring.
Mesa, A, Viñals, C, Pueyo, I, Roca, D, Vidal, M, Giménez, M, Conget, I
Diabetes research and clinical practice. 2020;:108354
-
-
Free full text
-
Abstract
AIMS: Spain has been one of the worst affected countries by the COVID-19 pandemic. A very strict lockdown at home was imposed with a tough restriction of mobility. We aimed to evaluate the impact of this exceptional scenario on glucose profile of patients with T1D prone to hypoglycemia using standalone continuous glucose monitoring. METHODS Patients with T1D prone to hypoglycemia using multiple daily injections and either a Dexcom G5® or a Free Style Libre® CGM systems for at least 6 months under the funding of National Health Service were included in an observational, retrospective study. Data were collected in two periods: pre-lockdown (PL), February 23rd-March 7th and within lockdown (WL), April 1st-14th 2020. The primary outcome was the difference in the proportion of time in target glucose range of 70-180 mg/dL (TIR). Additional glucometric data were also analysed. RESULTS 92 patients were included: 40 women, age 42.8 ± 3.9 years, disease duration of 23.1 ± 12.6 years. Seventeen patients used Dexcom G5® and 75 Free Style Libre®. TIR 70-180 mg/dL (59.3 ± 16.2 vs 62.6 ± 15.2%), time > 180 (34.4 ± 18.0 vs 30.7 ± 16.9%), >250 (11.1 ± 10.6 vs 9.2 ± 9.7%) and Glucose Management Indicator (7.2 ± 0.8 vs 7.0 ± 0.8%) significantly improved (PL vs WL, respectively, p < 0.05). Time in hypoglycemia remained unchanged. CONCLUSIONS Lockdown conditions imposed by the COVID-19 pandemic may be managed successfully in terms of glycemic control by population with T1D prone to hypoglycemia using CGM. The strict daily routine at home could probably explain the improvement in the time in glycemic target without increasing the time in hypoglycemia.